Side view of ISO 80369-7 Figure C.2 male reference Luer slip connector
ISO 80369-7 Figure C.2 male reference Luer slip connector for female Luer connector testing
Detail view of ISO 80369-7 Figure C.2 male reference Luer slip connector
Angled view of ISO 80369-7 Figure C.2 male reference Luer slip connector
ISO 80369-7 Figure C.2 male reference Luer slip connector drawing for female Luer connector testing
Side view of ISO 80369-7 Figure C.2 male reference Luer slip connector
ISO 80369-7 Figure C.2 male reference Luer slip connector for female Luer connector testing
Detail view of ISO 80369-7 Figure C.2 male reference Luer slip connector
Angled view of ISO 80369-7 Figure C.2 male reference Luer slip connector
ISO 80369-7 Figure C.2 male reference Luer slip connector drawing for female Luer connector testing

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector

The ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is used for testing female Luer connectors in intravascular and hypodermic medical device applications. It provides the specified male reference mating interface for ISO 80369-7 related leakage, axial load separation, stress cracking and non-interconnectable characteristic evaluations.

  • Applicable Standard: ISO 80369-7 Figure C.2 / Annex C
  • Product Type: Male Reference Luer Slip Connector
  • Test Object: Female Luer connectors
  • Typical Test Applications: Leakage, separation from axial load, stress cracking and non-interconnectable characteristics
  • Connector Type: Male reference Luer slip connector
  • Cone Taper: 0.06:1 according to the Figure C.2 drawing
  • Supply Option: Individual Figure C.2 connector or part of a complete ISO 80369-7 Luer Gauge Set
  • Related Equipment: Used with applicable ISO 80369-20 test setups when leakage, axial load or other performance tests are required

Product Overview

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector

The ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is a precision reference connector used as the mating interface when evaluating female Luer connectors. It is not a general plug gauge and should not be confused with the ISO 80369-7 Male Plug Gauge or the Figure C.4 Male Reference Luer Lock Connector.

In a typical test setup, the female Luer connector sample is connected to the Figure C.2 male reference Luer slip connector. The assembled connection is then used with the applicable ISO 80369-7 and ISO 80369-20 test procedure, depending on whether the customer needs leakage, separation, stress cracking or non-interconnectability evaluation.


Key Drawing Notes

Based on the ISO 80369-7 Figure C.2 drawing, the following points are important for product selection and test configuration:

Item Figure C.2 Note
Figure Number ISO 80369-7 Figure C.2
Reference Connector Type Male reference Luer slip connector
Test Object Female Luer connectors
Cone Taper 0.06:1
Male Taper Length Minimum 10.5 mm for non-interconnectable characteristic testing
Clause 6 Performance Test Note Minimum 7.5 mm may be used for Clause 6 performance tests
Edge Requirement Radius or chamfer not to exceed 0.5 mm
Dimension Unit Millimetres unless otherwise indicated

Only confirmed drawing dimensions should be shown on the final product page. If the customer requires material, hardness, dimensional verification or documentation, these items should be confirmed before quotation.

ISO 80369-7 Figure C.2 male reference Luer slip connector drawing for female Luer connector testing


How It Is Used and What It Tests

Typical Use Procedure

  1. Confirm that the sample is a female Luer connector and that ISO 80369-7 Figure C.2 is the required reference connector.
  2. Mate the female connector sample with the Figure C.2 male reference Luer slip connector.
  3. Install the assembled connection into the required ISO 80369 test setup.
  4. Apply the specified pressure, axial load, stress condition or non-interconnectability check according to the selected test method.
  5. Record the result according to the applicable test procedure.
  6. After testing, clean and protect the reference connector to avoid scratches, contamination or deformation.

Typical Test Applications

The Figure C.2 reference connector may be used in test configurations related to:

  • Leakage evaluation
  • Separation from axial load
  • Stress cracking evaluation
  • Non-interconnectable characteristics
  • Female Luer connector design verification
  • Routine quality control of Luer connector assemblies

The exact pressure, load, time and test condition should be confirmed according to the applicable ISO 80369 test method and the customer’s sample design.


Technical Features

  • Designed according to ISO 80369-7 Figure C.2 reference connector requirements
  • Male reference Luer slip interface for female Luer connector testing
  • 0.06:1 cone taper according to the Figure C.2 drawing
  • Precision-machined reference surface for repeatable mating with female Luer samples
  • Suitable for use in ISO 80369-7 related leakage, axial load, stress cracking and non-interconnectability test configurations
  • Hardened steel or stainless steel configuration can be supplied according to project requirements
  • HRC58–62 hardness can be supplied where applicable and confirmed
  • Available individually or as part of a complete ISO 80369-7 Luer Gauge Set
  • Suitable for R&D validation, laboratory testing and factory quality control
  • Can be used with suitable ISO 80369-20 leakage, air leakage or axial load test equipment

Operation and Handling Notes

The Figure C.2 connector should be handled as a precision reference component, not as a general production connector.

  • Confirm the required figure number before testing.
  • Do not replace Figure C.2 with Figure C.4 or Figure C.6 unless the test procedure clearly requires another male reference connector.
  • Confirm whether the sample is a female Luer slip connector, female Luer lock connector or another specified female connector configuration.
  • Keep the mating surface clean and free from visible scratches.
  • Do not force the reference connector into an incompatible sample.
  • Avoid impact, corrosion or contamination during storage and use.
  • Store the connector in a protective case after testing.
  • Confirm whether dimensional verification or documentation is required for laboratory use.

Alternate angled view of ISO 80369-7 Figure C.2 male reference Luer slip connector


Who Needs This Connector

Customer Type Typical Need
Syringe manufacturers Female Luer connector design verification and production quality control
Needle and hypodermic accessory manufacturers Connector compatibility testing for Luer-based assemblies
IV cannula and infusion set manufacturers Female Luer interface performance evaluation
Medical device R&D teams Connector validation during product development
Third-party testing laboratories ISO 80369-7 test setup configuration for client samples
Factory QC laboratories Incoming inspection, batch verification or routine connector checking
Certification support teams Preparing samples and fixtures before formal ISO 80369 testing

This customer profile helps separate the C.2 page from the complete ISO 80369-7 Luer Gauge Set page. The C.2 page is for users who already know they need the Figure C.2 male reference Luer slip connector for a female Luer connector test.

Pair view of ISO 80369-7 Figure C.2 male reference Luer slip connectors
packing

Standards Compliance and Documentation Support

  • This ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is manufactured according to the Figure C.2 reference connector geometry for female Luer connector testing. It supports ISO 80369-7 related leakage, axial load separation, stress cracking and non-interconnectable characteristic evaluations when used with the appropriate test setup.

  • KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.

Product Datasheet

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector

Download the PDF datasheet for product overview, key drawing notes, operation notes and technical inquiry support.

Technical Inquiry & Expert Support

The ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:

  • Required product: ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
  • Quantity required
  • Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
  • Your sample type, such as female Luer slip connector or female Luer lock connector
  • Intended test application, such as leakage, axial load separation, stress cracking or non-interconnectable characteristics
  • Whether related ISO 80369-20 test equipment is also required
  • Any documentation requirement, such as dimensional report, material information or hardness confirmation

KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.2 is the correct reference connector for your ISO 80369-7 test setup.

Related KINGPO ISO 80369 Products

Related Product Suggested Anchor Text
ISO 80369-7 Luer Gauge Set ISO 80369-7 Luer Gauge Set
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector
ISO 80369-7 Figure C.6 Male Reference Connector ISO 80369-7 Figure C.6 Male Reference Connector
ISO 80369-7 Male Plug Gauge ISO 80369-7 Male Plug Gauge
ISO 80369-7 Female Ring Gauge ISO 80369-7 Female Ring Gauge
ISO 80369-20 Liquid Leakage Tester ISO 80369-20 Liquid Leakage Tester
ISO 80369-20 Annex D Air Leakage Tester ISO 80369-20 Annex D Air Leakage Tester
ISO 80369-20 Annex F Axial Load Tester ISO 80369-20 Annex F Axial Load Tester

Difference from Related ISO 80369-7 Gauges

Related Product Difference
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector Used for testing female Luer connectors with a male Luer slip reference interface
ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector Used where a male Luer lock reference connector is required
ISO 80369-7 Figure C.6 Male Reference Connector Used for female Luer lock connector testing in another Annex C configuration
ISO 80369-7 Male Plug Gauge Dimensional or fit-checking gauge; not the same as the Figure C.2 reference connector
ISO 80369-7 Luer Gauge Set Complete C.1–C.6 reference connector set for laboratories requiring multiple configurations
ISO 80369-20 Test Equipment Test apparatus used to apply leakage, air leakage, axial load or related test conditions

This distinction is important because using the wrong reference connector may lead to an incorrect test configuration.

ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector

FAQ

What is ISO 80369-7 Figure C.2 used for?
It is a male reference Luer slip connector used for testing female Luer connectors. It provides the specified mating interface for ISO 80369-7 related test configurations, including leakage, axial load separation, stress cracking and non-interconnectable characteristic evaluation.
Is Figure C.2 the same as a male plug gauge?
No. Figure C.2 is a reference connector used in specific ISO 80369-7 test configurations. A male plug gauge is generally used for dimensional or fit checking and should not be treated as the same product unless the test procedure clearly defines it that way.
Can Figure C.2 be used for female Luer lock connectors?
It may be used only when the selected test method requires the Figure C.2 male reference Luer slip connector. For some female Luer lock connector tests, Figure C.4 or Figure C.6 may be required instead. The correct figure number should be confirmed before testing.
Does this connector perform leakage testing by itself?
No. The connector is a reference component, not a complete leakage tester. For leakage testing, it must be used with the appropriate pressure source, fixture, measuring device and ISO 80369-20 test procedure.
Can this connector be supplied as part of a complete set?
Yes. The Figure C.2 connector can be supplied individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set. The complete set is recommended for laboratories testing multiple Luer connector configurations.
What information should be provided before ordering?
Please provide the required figure number, sample connector type, test item, quantity, material or hardness requirement, and whether you need only the Figure C.2 connector or a complete ISO 80369-7 / ISO 80369-20 test setup.

Related Products

Related News

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

Compare KP8850 and QA-ES III ESU Analyzers for accuracy, workflow, compliance, and usability to choose the right ESU Analyzer for your clinical or lab needs.
A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.
ISO 80369 test equipment checks medical connectors for compliance, preventing misconnections and ensuring patient safety in healthcare environments.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]