ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
The ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is used for testing female Luer connectors in intravascular and hypodermic medical device applications. It provides the specified male reference mating interface for ISO 80369-7 related leakage, axial load separation, stress cracking and non-interconnectable characteristic evaluations.
- Applicable Standard: ISO 80369-7 Figure C.2 / Annex C
- Product Type: Male Reference Luer Slip Connector
- Test Object: Female Luer connectors
- Typical Test Applications: Leakage, separation from axial load, stress cracking and non-interconnectable characteristics
- Connector Type: Male reference Luer slip connector
- Cone Taper: 0.06:1 according to the Figure C.2 drawing
- Supply Option: Individual Figure C.2 connector or part of a complete ISO 80369-7 Luer Gauge Set
- Related Equipment: Used with applicable ISO 80369-20 test setups when leakage, axial load or other performance tests are required
Product Overview
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
The ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is a precision reference connector used as the mating interface when evaluating female Luer connectors. It is not a general plug gauge and should not be confused with the ISO 80369-7 Male Plug Gauge or the Figure C.4 Male Reference Luer Lock Connector.
In a typical test setup, the female Luer connector sample is connected to the Figure C.2 male reference Luer slip connector. The assembled connection is then used with the applicable ISO 80369-7 and ISO 80369-20 test procedure, depending on whether the customer needs leakage, separation, stress cracking or non-interconnectability evaluation.
Key Drawing Notes
Based on the ISO 80369-7 Figure C.2 drawing, the following points are important for product selection and test configuration:
| Item | Figure C.2 Note |
|---|---|
| Figure Number | ISO 80369-7 Figure C.2 |
| Reference Connector Type | Male reference Luer slip connector |
| Test Object | Female Luer connectors |
| Cone Taper | 0.06:1 |
| Male Taper Length | Minimum 10.5 mm for non-interconnectable characteristic testing |
| Clause 6 Performance Test Note | Minimum 7.5 mm may be used for Clause 6 performance tests |
| Edge Requirement | Radius or chamfer not to exceed 0.5 mm |
| Dimension Unit | Millimetres unless otherwise indicated |
Only confirmed drawing dimensions should be shown on the final product page. If the customer requires material, hardness, dimensional verification or documentation, these items should be confirmed before quotation.

How It Is Used and What It Tests
Typical Use Procedure
- Confirm that the sample is a female Luer connector and that ISO 80369-7 Figure C.2 is the required reference connector.
- Mate the female connector sample with the Figure C.2 male reference Luer slip connector.
- Install the assembled connection into the required ISO 80369 test setup.
- Apply the specified pressure, axial load, stress condition or non-interconnectability check according to the selected test method.
- Record the result according to the applicable test procedure.
- After testing, clean and protect the reference connector to avoid scratches, contamination or deformation.
Typical Test Applications
The Figure C.2 reference connector may be used in test configurations related to:
- Leakage evaluation
- Separation from axial load
- Stress cracking evaluation
- Non-interconnectable characteristics
- Female Luer connector design verification
- Routine quality control of Luer connector assemblies
The exact pressure, load, time and test condition should be confirmed according to the applicable ISO 80369 test method and the customer’s sample design.
Technical Features
- Designed according to ISO 80369-7 Figure C.2 reference connector requirements
- Male reference Luer slip interface for female Luer connector testing
- 0.06:1 cone taper according to the Figure C.2 drawing
- Precision-machined reference surface for repeatable mating with female Luer samples
- Suitable for use in ISO 80369-7 related leakage, axial load, stress cracking and non-interconnectability test configurations
- Hardened steel or stainless steel configuration can be supplied according to project requirements
- HRC58–62 hardness can be supplied where applicable and confirmed
- Available individually or as part of a complete ISO 80369-7 Luer Gauge Set
- Suitable for R&D validation, laboratory testing and factory quality control
- Can be used with suitable ISO 80369-20 leakage, air leakage or axial load test equipment
Operation and Handling Notes
The Figure C.2 connector should be handled as a precision reference component, not as a general production connector.
- Confirm the required figure number before testing.
- Do not replace Figure C.2 with Figure C.4 or Figure C.6 unless the test procedure clearly requires another male reference connector.
- Confirm whether the sample is a female Luer slip connector, female Luer lock connector or another specified female connector configuration.
- Keep the mating surface clean and free from visible scratches.
- Do not force the reference connector into an incompatible sample.
- Avoid impact, corrosion or contamination during storage and use.
- Store the connector in a protective case after testing.
- Confirm whether dimensional verification or documentation is required for laboratory use.

Who Needs This Connector
| Customer Type | Typical Need |
|---|---|
| Syringe manufacturers | Female Luer connector design verification and production quality control |
| Needle and hypodermic accessory manufacturers | Connector compatibility testing for Luer-based assemblies |
| IV cannula and infusion set manufacturers | Female Luer interface performance evaluation |
| Medical device R&D teams | Connector validation during product development |
| Third-party testing laboratories | ISO 80369-7 test setup configuration for client samples |
| Factory QC laboratories | Incoming inspection, batch verification or routine connector checking |
| Certification support teams | Preparing samples and fixtures before formal ISO 80369 testing |
This customer profile helps separate the C.2 page from the complete ISO 80369-7 Luer Gauge Set page. The C.2 page is for users who already know they need the Figure C.2 male reference Luer slip connector for a female Luer connector test.

Standards Compliance and Documentation Support
-
This ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is manufactured according to the Figure C.2 reference connector geometry for female Luer connector testing. It supports ISO 80369-7 related leakage, axial load separation, stress cracking and non-interconnectable characteristic evaluations when used with the appropriate test setup.
-
KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
Technical Inquiry & Expert Support
The ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:
- Required product: ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
- Quantity required
- Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
- Your sample type, such as female Luer slip connector or female Luer lock connector
- Intended test application, such as leakage, axial load separation, stress cracking or non-interconnectable characteristics
- Whether related ISO 80369-20 test equipment is also required
- Any documentation requirement, such as dimensional report, material information or hardness confirmation
KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.2 is the correct reference connector for your ISO 80369-7 test setup.
Related KINGPO ISO 80369 Products
| Related Product | Suggested Anchor Text |
|---|---|
| ISO 80369-7 Luer Gauge Set | ISO 80369-7 Luer Gauge Set |
| ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector | ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector |
| ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector | ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector |
| ISO 80369-7 Figure C.6 Male Reference Connector | ISO 80369-7 Figure C.6 Male Reference Connector |
| ISO 80369-7 Male Plug Gauge | ISO 80369-7 Male Plug Gauge |
| ISO 80369-7 Female Ring Gauge | ISO 80369-7 Female Ring Gauge |
| ISO 80369-20 Liquid Leakage Tester | ISO 80369-20 Liquid Leakage Tester |
| ISO 80369-20 Annex D Air Leakage Tester | ISO 80369-20 Annex D Air Leakage Tester |
| ISO 80369-20 Annex F Axial Load Tester | ISO 80369-20 Annex F Axial Load Tester |
Difference from Related ISO 80369-7 Gauges
| Related Product | Difference |
|---|---|
| ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector | Used for testing female Luer connectors with a male Luer slip reference interface |
| ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector | Used where a male Luer lock reference connector is required |
| ISO 80369-7 Figure C.6 Male Reference Connector | Used for female Luer lock connector testing in another Annex C configuration |
| ISO 80369-7 Male Plug Gauge | Dimensional or fit-checking gauge; not the same as the Figure C.2 reference connector |
| ISO 80369-7 Luer Gauge Set | Complete C.1–C.6 reference connector set for laboratories requiring multiple configurations |
| ISO 80369-20 Test Equipment | Test apparatus used to apply leakage, air leakage, axial load or related test conditions |
This distinction is important because using the wrong reference connector may lead to an incorrect test configuration.
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
FAQ
Related Products
Related News
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]