Medical Test Equipment for Compliance Testing

KingPo provides medical test equipment for medical device safety, performance and compliance verification, covering electrical safety, electrosurgical, defibrillator, ECG electrode and medical connector testing according to international standards.

 · Medical Electrical Safety Testing – IEC 60601-1 safety verification, dielectric strength and leakage current testing

 · Electrosurgical Equipment Testing – IEC 60601-2-2 ESU output analysis, REM/CQM verification and neutral electrode evaluation

 · Defibrillator Testing – IEC 60601-2-4 energy measurement, defibrillation-proof and waveform verification

 · ECG Electrode and Patient Monitoring Testing – Electrode performance and electrical characteristic evaluation

 · Medical Connector Testing – ISO 80369-7, ISO 18250 and ISO 5364 connector verification solutions

Medical Device Testing Equipment Solutions

KingPo Medical Test Equipment includes dedicated solutions for medical electrical equipment, electrosurgical units, defibrillators, patient monitoring devices and medical connectors. The product range is designed to support laboratory testing, manufacturer verification and compliance evaluation according to applicable international standards.

Winding temperature rise tester angled view with test interface
Front view of KingPo KP-HF50 NE contact impedance tester for IEC 60601-2-2 laboratory testing
Front view of KINGPO KP-H500 500 kHz test equipment for ISO 14117 surgical exposure testing
Front view of the KP-1000 Mask Bacterial Filtration Efficiency Tester for medical face mask BFE testing
Front view of ISO 5356-1 conical connector test equipment for anaesthetic and respiratory equipment testing
Front view of the KR-3C IEC 61010-2-020 thermometer centrifuge for batch preparation and resetting of glass clinical thermometers.
Front view of KP3301 IEC 60601-1 Defibrillation-Proof and Energy Reduction Tester
IEC 60601-2-2 Clause 201.15.101.5 Neutral electrode CQM and temperature rise test equipment right-side view
ISO 80369-7 Figure C.1 to C.6 reference connectors in Luer gauge set
Opposite angle view of ISO 80369-7 Male Plug Gauge for female Luer connector inspection
Opposite angle view of ISO 80369-7 Female Ring Gauge for male Luer connector inspection
ISO 80369-7 Figure C.6 male reference connector shown in multiple product views
Angled view of ISO 80369-7 Figure C.5 female reference Luer slip connector
Vertical view of ISO 80369-7 Figure C.4 male reference Luer lock connector
ISO 80369-7 Figure C.3 female reference connector vertical view for male Luer lock connector testing
ISO 80369-7 Figure C.1 female reference Luer lock connector side view for male Luer connector testing
1 2 3 4 5 6

Ready to Ensure Your Medical Devices Meet Global Safety Standards?

Contact KingPo today for a free quote, technical consultation, or product catalog.

📩 Email: [email protected]

☎ Phone: +86-769-81627526

Typical Applications of KingPo Medical Test Equipment

Medical Device Certification Labs

IEC 60601 safety, performance and compliance verification testing

Defibrillator & Cardiac Equipment Manufacturers

Defibrillator energy measurement, waveform analysis and defibrillation-proof testing

Connector & Catheter Producers

ISO 80369 and ISO 18250 connector verification, leakage and functional testing

ECG Electrode & Patient Monitor R&D

ECG electrode performance and electrical characteristic evaluation

Altitude Simulation for Emergency Medical Devices

IEC 60601-1-11/-12 environmental simulation and low-pressure testing

Child Medical Bed & Handling Device Testing

BS EN 50637 cone tool & grip strength evaluation

Medical Test Equipment FAQs

What standards do KingPo Medical Test Equipment comply with?

KingPo Medical Test Equipment supports testing requirements based on IEC 60601 series, ISO 80369, ISO 18250, ISO 5364 and other applicable medical device standards. The specific test method depends on the device type and compliance requirements.

What types of medical devices can be tested with KingPo equipment?

KingPo solutions support testing for a wide range of medical products, including medical electrical equipment, electrosurgical units, defibrillators, ECG electrodes, patient monitoring devices, and medical connectors used in healthcare applications.

What tests are included in medical electrical safety testing?

Medical electrical safety testing typically includes dielectric strength, leakage current, protective earth verification and other electrical safety evaluations required for medical devices according to applicable standards such as IEC 60601-1.

Which KingPo equipment is used for electrosurgical unit testing?

KingPo provides electrosurgical testing solutions for evaluating ESU output performance, REM/CQM monitoring functions, neutral electrode characteristics and related requirements according to IEC 60601-2-2.

Do you provide testing solutions for defibrillator verification?

Yes. KingPo offers defibrillator testing equipment designed for energy measurement, waveform analysis, defibrillation-proof evaluation and energy reduction verification according to applicable defibrillator testing requirements.

Can KingPo provide customized medical testing solutions?

Yes. KingPo can provide customized configurations based on product type, test requirements and applicable standards. Our engineers can help select suitable test equipment for laboratory verification and compliance evaluation.

Medical Compliance Test Series – Precision Meets Global Standards