ISO 80369-7 Female Ring Gauge for Male Luer Connector Verification
The ISO 80369-7 Female Ring Gauge is a precision dimensional gauge used for checking male Luer connectors in intravascular and hypodermic medical device applications. It provides a controlled female ring interface to help verify whether the male Luer connector sample matches the required Luer taper and mating condition according to ISO 80369-7 dimensional requirements.
- Applicable Standard: ISO 80369-7 dimensional requirements for Luer connectors
- Product Type: Female Ring Gauge / Luer Dimensional Gauge
- Test Object: Male Luer connectors
- Main Purpose: Dimensional and fit verification of the male Luer connector interface
- Typical Check: Luer taper fit, insertion condition and mating geometry
- Material / Hardness: Hardened steel configuration; HRC58–62 can be stated only if confirmed by the supplied product specification
- Important Note: This is a dimensional / fit verification gauge, not an ISO 80369-20 leakage tester or Annex C reference connector
- Supply Option: Individual female ring gauge or part of an ISO 80369-7 Luer gauge set
Product Overview
ISO 80369-7 Female Ring Gauge
The ISO 80369-7 Female Ring Gauge is used to verify the external mating geometry of male Luer connectors. Instead of applying leakage pressure, axial load or stress cracking conditions, this gauge helps the user check whether the male Luer connector fits correctly with a controlled female gauge interface.
This product should not be confused with the ISO 80369-7 Figure C.1, C.3 or C.5 female reference connectors. Those Annex C reference connectors are used in specific performance test configurations, while the Female Ring Gauge is mainly used for dimensional and fit verification based on Luer connector geometry.
For laboratories, medical device manufacturers and QC teams, this gauge is useful before formal functional testing. It helps identify whether a male Luer connector sample has an obvious dimensional or mating issue before using ISO 80369-20 leakage, air leakage or axial load test equipment.
Standard Background and Correct Positioning
ISO 80369-7 includes dimensional requirements for Luer connectors and provides Luer connector dimension figures and tables in Annex B. The Female Ring Gauge is best understood as a practical inspection gauge based on those Luer connector dimensional requirements.
It is different from ISO 80369-7 Annex C reference connectors:
| Item | Correct Understanding |
|---|---|
| Female Ring Gauge | Dimensional / fit verification gauge for male Luer connectors |
| Annex C Reference Connectors | Reference connectors used in specified ISO 80369-7 performance test configurations |
| ISO 80369-20 Test Equipment | Test apparatus used for leakage, air leakage, axial load or related performance tests |
This distinction is important for both purchasing and page SEO. Customers searching for a Female Ring Gauge usually need a dimensional inspection tool, not a complete test system.
What This Female Ring Gauge Checks
The Female Ring Gauge is used to check male Luer connector samples. The working end of the gauge provides a female ring / internal interface. During inspection, the male Luer connector is inserted into or mated with the gauge to evaluate whether the external Luer taper and mating condition are suitable.
Typical verification purposes include:
- Checking the external Luer taper of a male Luer connector
- Confirming basic mating fit before further functional testing
- Supporting incoming inspection of male Luer connector components
- Helping R&D teams compare connector samples during design verification
- Supporting factory QC checks for production batches
This gauge does not replace a complete leakage tester, axial load tester or resistance-to-overriding test setup.
How It Is Used
Typical Use Procedure
- Confirm that the sample is a male Luer connector.
- Clean the sample and the Female Ring Gauge working interface before inspection.
- Insert or mate the male Luer connector with the female ring gauge interface according to the internal inspection procedure.
- Observe whether the connector fits the gauge as expected.
- Record the inspection result according to the laboratory or factory QC requirement.
- After inspection, clean the gauge and store it in a protective case.
Important Use Note
The Female Ring Gauge should be used only for dimensional or fit verification. If the customer needs leakage, sub-atmospheric pressure air leakage, axial load separation, unscrewing separation, stress cracking or resistance-to-overriding testing, the appropriate ISO 80369-20 test apparatus and ISO 80369-7 reference connector should be selected according to the test method.
Technical Features
- Designed for ISO 80369-7 related male Luer connector dimensional and fit verification
- Female ring gauge interface for checking male Luer connector mating geometry
- Suitable for male Luer connector incoming inspection, R&D checking and factory QC
- Precision-machined working interface for repeatable fit verification
- Hardened steel construction can be supplied according to product specification
- HRC58–62 hardness may be stated when confirmed by KINGPO’s product drawing or inspection document
- Compact hand-held structure for convenient laboratory or production inspection
- Available individually or as part of a Luer connector gauge set
- Product datasheet, material information, dimensional confirmation or hardness confirmation can be provided where applicable
Operation and Handling Notes
The Female Ring Gauge is a precision inspection tool and should be handled carefully.
- Confirm the sample is a male Luer connector before use.
- Do not use this gauge as a leakage tester or force test fixture.
- Keep the ring gauge interface clean and free from scratches.
- Do not force an obviously incompatible or damaged connector into the gauge.
- Avoid impact, corrosion or contamination during storage and use.
- Store the gauge in a protective case after inspection.
- Confirm documentation requirements before order placement if the gauge will be used in a regulated laboratory or internal QC system.
Who Needs This Gauge
| Customer Type | Typical Need |
|---|---|
| Male Luer connector manufacturers | Routine dimensional and fit verification of male Luer connector samples |
| Syringe and needle manufacturers | Incoming inspection and production QC of male Luer connector parts |
| IV cannula and infusion accessory manufacturers | Checking male Luer connector mating condition before assembly or testing |
| Medical device R&D teams | Comparing connector prototypes during design verification |
| Third-party testing laboratories | Pre-checking customer samples before formal ISO 80369 testing |
| Factory QC laboratories | Batch inspection and internal quality control |
| Certification support teams | Preparing dimensional evidence before performance testing |
Compliance & Regulatory Assurance
This ISO 80369-7 Female Ring Gauge is manufactured for dimensional and fit verification of male Luer connectors according to ISO 80369-7 related Luer connector requirements. It helps customers check the mating condition of male Luer connector samples before further functional testing.
KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.
|
Product Datasheet
ISO 80369-7 Female Ring GaugeDownload the PDF datasheet for product overview, dimensional verification purpose, use notes and technical inquiry support.
|
Download Datasheet |
Technical Inquiry & Expert Support
The ISO 80369-7 Female Ring Gauge is a standard dimensional / fit verification gauge. To help KINGPO confirm the correct item and supporting documentation, please provide:
- Required product: ISO 80369-7 Female Ring Gauge
- Quantity required
- Your sample type, especially male Luer slip or male Luer lock connector
- Whether the gauge is required individually or as part of a Luer gauge set
- Intended use, such as R&D checking, incoming inspection or production QC
- Any material, hardness or dimensional confirmation requirement
- Whether related ISO 80369-20 performance test equipment is also required
KINGPO can help review your sample type and inspection purpose before quotation to confirm whether the Female Ring Gauge or another ISO 80369-7 gauge is more suitable.
Difference from Related ISO 80369-7 Products
| Related Product | Difference |
|---|---|
| ISO 80369-7 Female Ring Gauge | Dimensional / fit verification gauge for male Luer connectors |
| ISO 80369-7 Male Plug Gauge | Dimensional / fit verification gauge for female Luer connectors |
| ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector | Annex C reference connector used in specific male Luer connector test configurations |
| ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector | Annex C female reference connector for male Luer connector performance test configurations |
| ISO 80369-7 Luer Gauge Set | Complete set option for laboratories needing multiple Luer gauges and reference connectors |
| ISO 80369-20 Test Equipment | Test apparatus for leakage, air leakage, axial load or other performance tests |
This distinction helps customers avoid selecting an Annex C reference connector when they only need a dimensional / fit verification gauge.
ISO 80369-7 Female Ring Gauge
FAQ
Related Products
Related News
KingPo supplied ISO 80369-7 Luer Gauges to Angiosistemy LLC in Russia. The gauges are used for laboratory testing of medical […]
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]