ISO80369-20 Annex D Subatmospheric Air Leakage Tester
ISO80369-20 Annex D Subatmospheric Air Leakage Tester

ISO80369-20 Annex D Subatmospheric Air Leakage Tester

The ISO 80369-20 Annex D Subatmospheric Air Leakage Tester is used for air leakage testing of medical small-bore connectors under subatmospheric pressure conditions. It provides a controlled negative-pressure test condition for evaluating connector sealing performance in ISO 80369-20 Annex D related test applications.

  • Applicable Standard: ISO 80369-20 Annex D
  • Product Type: Subatmospheric Air Leakage Tester / Medical Connector Air Leakage Tester
  • Test Object: Medical small-bore connectors, Luer connector assemblies and related connector samples
  • Main Test Purpose: Air leakage testing under subatmospheric pressure conditions
  • Typical Application: Medical device R&D, connector verification, QC inspection and laboratory testing
  • Related Fixtures: Connector fixtures and ISO 80369-7 reference connectors may be required depending on the sample and test method
  • Configuration: Pressure range, fixture design, data recording and documentation support should be confirmed according to project requirements

Detail Information

The ISO 80369-20 Annex D Subatmospheric Air Leakage Tester is designed for medical small-bore connector air leakage evaluation under controlled negative-pressure conditions. Unlike liquid leakage testing, Annex D focuses on air leakage behavior when the connector assembly is exposed to a subatmospheric pressure condition.

This tester is suitable for medical device manufacturers, R&D laboratories, quality control departments and third-party testing laboratories that need to verify connector sealing performance according to ISO 80369-20 Annex D related test requirements. Depending on the sample type, the tester may be used together with suitable connector fixtures, adapters or ISO 80369-7 reference connectors.

For customers working with Luer slip, Luer lock or other small-bore connector assemblies, KINGPO can help review the connector type and test method before quotation to confirm the proper fixture and test configuration.


What Annex D Subatmospheric Air Leakage Testing Verifies

ISO 80369-20 Annex D air leakage testing is used to evaluate whether a medical small-bore connector assembly can maintain sealing performance under subatmospheric pressure. The test is especially relevant when the connector design, mating condition or assembly quality may affect air tightness.

Typical verification purposes include:

  • Checking air leakage behavior of medical small-bore connector assemblies
  • Evaluating Luer connector sealing performance under negative-pressure conditions
  • Supporting R&D verification for connector design changes
  • Supporting incoming inspection or production QC for connector components
  • Preparing samples for ISO 80369 related type testing or internal validation

This tester is not a liquid leakage tester and should not be used to replace ISO 80369-20 Annex B / Annex C liquid leakage testing equipment.


Testing Principle

During the test, the connector sample is installed on a suitable fixture or reference connector configuration. The tester applies a controlled subatmospheric pressure condition to the connector assembly. The system then monitors the leakage-related response, such as pressure change or air leakage result, according to the selected test method and equipment configuration.

The actual test setup depends on the connector type, sample geometry and required ISO 80369-20 Annex D test procedure. For Luer connector samples, appropriate ISO 80369-7 reference connectors may be required to create the correct mating interface.

The tester helps laboratories perform repeatable air leakage evaluation while keeping the sample connection, pressure condition and result recording under controlled test conditions.


Difference from ISO 80369-20 Liquid Leakage Tester

Item Annex D Air Leakage Tester Liquid Leakage Tester
Test Method ISO 80369-20 Annex D ISO 80369-20 Annex B / Annex C
Test Medium Air Liquid
Pressure Condition Subatmospheric / negative-pressure condition Pressure / positive-pressure liquid leakage condition
Main Purpose Air leakage evaluation Liquid leakage evaluation
Typical Page Focus Connector air tightness under negative pressure Connector liquid sealing performance
Related Equipment Air leakage tester, fixture, reference connector Liquid leakage tester, pressure system, fixture, reference connector

This difference should be clearly shown on the page so customers do not confuse Annex D air leakage testing with Annex B / Annex C liquid leakage testing.


Typical Test Objects

The ISO 80369-20 Annex D Air Leakage Tester can be configured for different medical small-bore connector samples, depending on the test method and fixture requirement.

Typical test objects include:

  • Luer connector assemblies
  • Male and female Luer slip connector samples
  • Male and female Luer lock connector samples
  • Syringe and needle connector assemblies
  • Infusion connector components
  • Catheter connector assemblies
  • Medical small-bore connector prototypes
  • Connector samples requiring ISO 80369 related air leakage verification

For non-standard samples or special connector geometry, the fixture configuration should be confirmed before quotation.


Technical Features

  • Designed for ISO 80369-20 Annex D related subatmospheric air leakage testing
  • Provides controlled negative-pressure / subatmospheric test conditions
  • Suitable for medical small-bore connectors and Luer connector assemblies
  • Fixture configuration can be matched to the customer’s sample type
  • Can be used with appropriate ISO 80369-7 reference connectors where required
  • Supports repeatable connector air leakage evaluation in R&D and QC laboratories
  • Test process and result recording can be configured according to project requirements
  • Documentation or calibration information can be provided where applicable
  • Suitable for manufacturers, testing laboratories and medical device quality teams

Technical Configuration Notes

Because connector samples and laboratory test methods may differ, the final tester configuration should be confirmed according to the required ISO 80369-20 Annex D test scope.

Item Configuration Note
Applicable Standard ISO 80369-20 Annex D
Test Type Subatmospheric air leakage testing
Test Medium Air
Pressure Condition Subatmospheric / negative-pressure condition, confirmed according to the required test method
Test Object Medical small-bore connectors and Luer connector assemblies
Fixture Standard or customized fixture depending on connector type
Reference Connectors ISO 80369-7 reference connectors may be required for Luer connector samples
Data Recording Available depending on selected configuration
Documentation Datasheet, configuration confirmation or calibration documentation can be provided where applicable

Do not list unconfirmed pressure range, leakage range, resolution or accuracy values on the page unless they are supported by the actual product specification or calibration document.


Operation and Handling Notes

Before testing, the user should confirm the sample type, connector gender, mating interface and applicable test procedure. The fixture and connector interface should be clean and properly installed to avoid false leakage results caused by poor sample mounting.

During operation, the tester should be used according to the selected Annex D test method and internal laboratory procedure. The sample should not be forced into an incompatible fixture or reference connector. After testing, the fixture and connector interface should be cleaned and stored properly to maintain repeatable test conditions.

For regulated laboratories or formal verification projects, documentation requirements should be confirmed before order placement, including calibration document, configuration list, fixture drawing or test record format where applicable.


Relationship with ISO 80369-7 Reference Connectors

ISO 80369-20 provides common test methods for small-bore connector performance evaluation, while ISO 80369-7 is commonly associated with intravascular and hypodermic Luer connector applications. For Luer connector testing, the correct reference connector or gauge may be required depending on the connector type and test method.

For example:

  • Female Luer connector samples may require suitable male reference connectors.
  • Male Luer connector samples may require suitable female reference connectors.
  • Dimensional pre-checking may require the ISO 80369-7 Male Plug Gauge or Female Ring Gauge.
  • A complete ISO 80369-7 Luer Gauge Set may be useful for laboratories handling multiple connector types.

KINGPO can help confirm whether the Annex D Air Leakage Tester should be supplied with specific ISO 80369-7 reference connectors, dimensional gauges or customized fixtures.

 

Compliance & Regulatory AssuranceProduct Description

The ISO 80369-20 Annex D Subatmospheric Air Leakage Tester is designed for Annex D related air leakage testing of medical small-bore connectors under subatmospheric pressure conditions. It supports laboratories and medical device manufacturers in evaluating connector sealing performance according to the selected ISO 80369-20 test method and sample configuration.

Because ISO 80369 testing may involve different connector types, reference connectors, fixtures and documentation requirements, the final configuration should be confirmed before order placement. KINGPO can provide product datasheet, configuration information, fixture confirmation and documentation support where applicable.

This equipment should be selected together with the appropriate connector fixtures or ISO 80369-7 reference connectors when Luer connector samples are involved. For formal laboratory use, please confirm the required calibration document, test record format and reference connector configuration before quotation.

Technical Inquiry & Expert Support

To help KINGPO confirm the correct Annex D air leakage test configuration, please provide the following information:

  • Applicable standard and annex: ISO 80369-20 Annex D
  • Connector type: Luer slip, Luer lock or other medical small-bore connector
  • Sample gender and structure: male connector, female connector or assembled connector
  • Sample drawing, photos or interface dimensions, if available
  • Required test condition or internal test procedure
  • Whether ISO 80369-7 reference connectors are required
  • Fixture requirement: standard fixture or customized sample holder
  • Data recording, report format or software requirement
  • Calibration or documentation requirement
  • Quantity and expected project schedule

This information helps avoid selecting the wrong leakage tester, fixture or reference connector.

Key Features

Related Equipment Main Difference
ISO 80369-20 Annex D Air Leakage Tester Used for subatmospheric air leakage testing of medical small-bore connectors under Annex D related conditions.
ISO 80369-20 Liquid Leakage Tester Used for Annex B / Annex C liquid leakage testing of medical small-bore connectors.
ISO 80369-20 Annex F Axial Load Tester Used for axial load separation testing of medical small-bore connectors.
ISO 80369-20 Medical Small-Bore Connector Test Equipment Series page for selecting different ISO 80369-20 liquid leakage, air leakage and axial load test equipment configurations.
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector Female Luer lock reference connector used in specific male Luer connector test configurations.
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector Male Luer slip reference connector used in specific female Luer connector test configurations.
ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector Male Luer lock reference connector used in related female Luer connector test configurations.
ISO 80369-7 Figure C.6 Male Reference Connector Reference connector for female Luer lock connector separation from axial load and resistance to overriding tests.
ISO 80369-7 Male Plug Gauge Dimensional and fit verification gauge for checking female Luer connectors.
ISO 80369-7 Female Ring Gauge Dimensional and fit verification gauge for checking male Luer connectors.

FAQ

What is the ISO 80369-20 Annex D Air Leakage Tester used for?
It is used for subatmospheric air leakage testing of medical small-bore connectors. The tester creates a controlled negative-pressure condition and helps evaluate whether the connector assembly maintains the required sealing performance under Annex D related test conditions.
Is this tester for liquid leakage or air leakage?
This product is for air leakage testing under subatmospheric pressure conditions. If your project requires Annex B or Annex C liquid leakage testing, the ISO 80369-20 Liquid Leakage Tester should be selected instead.
What does subatmospheric pressure mean in this application?
Subatmospheric pressure means the test condition is below atmospheric pressure. In Annex D related testing, this condition is used to evaluate air leakage behavior of a connector assembly when negative pressure is applied.
Do I need ISO 80369-7 reference connectors for this tester?
It depends on the sample and test method. For Luer connector samples, suitable ISO 80369-7 reference connectors may be required to create the correct mating interface. KINGPO can help confirm the required reference connector based on your sample type.
What connector samples can be tested?
The tester can be configured for medical small-bore connector samples, including Luer slip connectors, Luer lock connectors, syringe and needle connector assemblies, infusion connector components and other connector assemblies related to ISO 80369 testing.
Can the fixture be customized for my connector sample?
Yes. Fixture design can be confirmed according to the connector structure, sample drawing and required test method. For non-standard samples, please provide photos, drawings or sample dimensions before quotation.
Can KINGPO provide calibration or documentation?
KINGPO can provide datasheet, configuration information and documentation support where applicable. Calibration documentation should be confirmed before order placement according to the selected configuration and customer laboratory requirements.
How is this different from the ISO 80369-20 Axial Load Tester?
The Annex D Air Leakage Tester checks air leakage under subatmospheric pressure. The Annex F Axial Load Tester applies mechanical force to evaluate connector separation resistance. They are different test methods and should not be used interchangeably.
Can this tester be supplied as part of a complete ISO 80369 test solution?
Yes. Depending on the customer’s test scope, KINGPO can support Annex D air leakage testing together with ISO 80369-20 liquid leakage testing, Annex F axial load testing and ISO 80369-7 Luer reference connectors or gauges.
What should I provide before requesting a quotation?
Please provide the applicable annex, connector type, sample gender, sample drawing or photos, required test condition, fixture requirement, data recording requirement and documentation needs. This helps KINGPO confirm the correct configuration.