Vertical view of ISO 80369-7 Figure C.1 female reference Luer lock connector
Full body view of ISO 80369-7 Figure C.1 female reference Luer lock connector
Interface view of ISO 80369-7 Figure C.1 female reference Luer lock connector
ISO 80369-7 Figure C.1 female reference Luer lock connector side view for male Luer connector testing
ISO 80369-7 Figure C.1 female reference Luer lock connector drawing for testing male Luer connectors
Vertical view of ISO 80369-7 Figure C.1 female reference Luer lock connector
Full body view of ISO 80369-7 Figure C.1 female reference Luer lock connector
Interface view of ISO 80369-7 Figure C.1 female reference Luer lock connector
ISO 80369-7 Figure C.1 female reference Luer lock connector side view for male Luer connector testing
ISO 80369-7 Figure C.1 female reference Luer lock connector drawing for testing male Luer connectors

ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector

The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is a standard reference connector used for testing male Luer connectors in intravascular and hypodermic medical device applications. It provides the specified female Luer lock reference interface for ISO 80369-7 related evaluations, including leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics.

  • Applicable Standard: ISO 80369-7 Figure C.1 / Annex C
  • Product Type: Female Reference Luer Lock Connector
  • Test Object: Male Luer connectors
  • Typical Test Applications: Leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics
  • Connector Type: Female reference Luer lock connector
  • Supply Option: Individual Figure C.1 connector or part of a complete ISO 80369-7 Luer Gauge Set
  • Related Equipment: Used with applicable ISO 80369-20 test setups when performance testing is required

Product Overview

ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector

The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is used as the controlled mating component when evaluating male Luer connectors. It is designed for test configurations that require a female Luer lock reference interface and should not be confused with the ISO 80369-7 Female Ring Gauge or the Figure C.5 Female Reference Luer Slip Connector.

In use, the male Luer connector sample is mated with the Figure C.1 female reference Luer lock connector. The assembled connection is then tested according to the applicable ISO 80369-7 and ISO 80369-20 procedure, depending on the required evaluation item.

This product is suitable for medical device manufacturers, laboratories and quality control teams that need a reliable reference connector for male Luer connector verification.


Key Drawing Notes

Based on the ISO 80369-7 Figure C.1 drawing, this product should be identified as a female reference Luer lock connector for male Luer connector testing.

Item Figure C.1 Note
Figure Number ISO 80369-7 Figure C.1
Reference Connector Type Female reference Luer lock connector
Test Object Male Luer connectors
Typical Test Applications Leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics
Key Interface Female Luer lock reference interface
Dimension Unit Millimetres unless otherwise indicated

The final product page should only show confirmed dimensions from the product drawing or supplied datasheet. Material, hardness, dimensional report or documentation requirements can be confirmed before order placement.

ISO 80369-7 Figure C.1 female reference Luer lock connector drawing for testing male Luer connectors


How It Is Used and What It Tests

Typical Use Procedure

  1. Confirm that the sample is a male Luer connector and that ISO 80369-7 Figure C.1 is the required reference connector.
  2. Mate the male Luer sample with the Figure C.1 female reference Luer lock connector.
  3. Install the assembled connection into the required ISO 80369 test setup.
  4. Apply the specified leakage, unscrewing, stress cracking or non-interconnectability test condition.
  5. Record the result according to the selected test method.
  6. After testing, clean the connector and protect the reference interface from damage.

Typical Test Applications

The Figure C.1 connector is typically used in configurations related to:

  • Leakage evaluation
  • Separation from unscrewing
  • Stress cracking evaluation
  • Non-interconnectable characteristics
  • Male Luer connector design verification
  • Laboratory or factory quality control of Luer connector assemblies

The exact test condition should be confirmed according to the applicable test method and the customer’s sample structure.


Technical Features

  • Designed according to ISO 80369-7 Figure C.1 reference connector geometry
  • Female Luer lock reference interface for male Luer connector testing
  • Suitable for ISO 80369-7 related leakage, unscrewing separation, stress cracking and non-interconnectability test configurations
  • Precision-machined reference mating surface for repeatable connector engagement
  • Hardened steel or stainless steel configuration can be supplied according to project requirements
  • HRC58–62 hardness can be supplied where applicable and confirmed
  • Available individually or as part of a complete ISO 80369-7 Luer Gauge Set
  • Suitable for R&D validation, laboratory testing and factory quality control
  • Can be used with suitable ISO 80369-20 leakage, air leakage or related test equipment

Operation and Handling Notes

The Figure C.1 connector should be handled as a precision reference component.

  • Confirm the required figure number before testing.
  • Do not replace Figure C.1 with Figure C.3 or Figure C.5 unless the selected procedure requires that configuration.
  • Confirm whether the tested sample is a male Luer slip connector, male Luer lock connector or another specified male Luer configuration.
  • Keep the female reference interface clean and free from scratches.
  • Do not force the connector onto an incompatible sample.
  • Avoid impact, corrosion or contamination during storage and use.
  • Store the connector in a protective case after testing.
  • Confirm documentation requirements before order placement if the connector will be used in a regulated laboratory environment.

Standards Compliance and Documentation Support

This ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is manufactured according to the Figure C.1 reference connector geometry for male Luer connector testing. It supports ISO 80369-7 related leakage, separation from unscrewing, stress cracking and non-interconnectable characteristic evaluations when used with the appropriate test setup.

KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.


Who Needs This Connector

Customer Type Typical Need
Syringe and needle manufacturers Male Luer connector verification and quality control
IV cannula and infusion accessory manufacturers Luer lock interface testing for medical connector assemblies
Medical device R&D teams Design validation of male Luer connector structures
Third-party testing laboratories ISO 80369-7 test setup preparation for customer samples
Factory QC laboratories Incoming inspection and production batch checking
Certification support teams Preparing suitable reference connectors before formal testing

This page is intended for users who already know they need the Figure C.1 female reference Luer lock connector. Customers looking for a full ISO 80369-7 connector set should refer to the complete ISO 80369-7 Luer Gauge Set.

Compliance & Regulatory Assurance

The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is manufactured according to the Figure C.1 reference connector geometry for testing male Luer connectors. It supports ISO 80369-7 related leakage, separation from unscrewing, stress cracking and non-interconnectable characteristic evaluations when used with the appropriate test setup and procedure.

KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. If additional documentation is required for laboratory procurement or internal quality control, please confirm it before order placement.

Product Datasheet
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
Download the PDF datasheet for product overview, key drawing notes, operation notes and technical inquiry support.
Download Datasheet

Technical Inquiry & Expert Support

The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:

  • Required product: ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
  • Quantity required
  • Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
  • Your sample type, such as male Luer slip connector or male Luer lock connector
  • Intended test application, such as leakage, separation from unscrewing, stress cracking or non-interconnectable characteristics
  • Whether related ISO 80369-20 test equipment is also required
  • Any documentation requirement, such as dimensional report, material information or hardness confirmation

KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.1 is the correct reference connector for your ISO 80369-7 test setup.

Related KINGPO ISO 80369 Products

Related Product Suggested Anchor Text
ISO 80369-7 Luer Gauge Set ISO 80369-7 Luer Gauge Set
ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
ISO 80369-7 Figure C.3 Female Reference Connector ISO 80369-7 Figure C.3 Female Reference Connector
ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector
ISO 80369-7 Female Ring Gauge ISO 80369-7 Female Ring Gauge
ISO 80369-20 Liquid Leakage Tester ISO 80369-20 Liquid Leakage Tester
ISO 80369-20 Annex D Air Leakage Tester ISO 80369-20 Annex D Air Leakage Tester
ISO 80369-20 Annex F Axial Load Tester ISO 80369-20 Annex F Axial Load Tester

ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector

FAQ

What is ISO 80369-7 Figure C.1 used for?
It is a female reference Luer lock connector used for testing male Luer connectors. It provides the specified reference mating interface for ISO 80369-7 related test configurations, including leakage, separation from unscrewing, stress cracking and non-interconnectable characteristic evaluation.
Is Figure C.1 the same as a female ring gauge?
No. Figure C.1 is a reference connector used in specified ISO 80369-7 test configurations. A female ring gauge is generally used for dimensional verification and should not be treated as the same product.
What is the difference between Figure C.1 and Figure C.5?
Both are female reference connectors for male Luer connector testing, but Figure C.1 provides a female Luer lock reference interface, while Figure C.5 is a female reference Luer slip connector. The correct figure depends on the selected test procedure.
Does this connector perform leakage testing by itself?
No. It is a reference connector, not a complete leakage tester. For leakage testing, it must be used with the appropriate pressure source, fixture, measuring device and ISO 80369-20 related test method.
Can this connector be supplied as part of a complete set?
Yes. The Figure C.1 connector can be supplied individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set. The full set is recommended for laboratories testing multiple Luer connector configurations.
What information should be provided before ordering?
Please provide the required product name, quantity, sample connector type, intended test application and any documentation requirement. KINGPO can help confirm whether Figure C.1 or another ISO 80369-7 reference connector is needed.

Related Products

Related News

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

Compare KP8850 and QA-ES III ESU Analyzers for accuracy, workflow, compliance, and usability to choose the right ESU Analyzer for your clinical or lab needs.
A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.
ISO 80369 test equipment checks medical connectors for compliance, preventing misconnections and ensuring patient safety in healthcare environments.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.