ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is a standard reference connector used for testing male Luer connectors in intravascular and hypodermic medical device applications. It provides the specified female Luer lock reference interface for ISO 80369-7 related evaluations, including leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics.
- Applicable Standard: ISO 80369-7 Figure C.1 / Annex C
- Product Type: Female Reference Luer Lock Connector
- Test Object: Male Luer connectors
- Typical Test Applications: Leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics
- Connector Type: Female reference Luer lock connector
- Supply Option: Individual Figure C.1 connector or part of a complete ISO 80369-7 Luer Gauge Set
- Related Equipment: Used with applicable ISO 80369-20 test setups when performance testing is required
Product Overview
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is used as the controlled mating component when evaluating male Luer connectors. It is designed for test configurations that require a female Luer lock reference interface and should not be confused with the ISO 80369-7 Female Ring Gauge or the Figure C.5 Female Reference Luer Slip Connector.
In use, the male Luer connector sample is mated with the Figure C.1 female reference Luer lock connector. The assembled connection is then tested according to the applicable ISO 80369-7 and ISO 80369-20 procedure, depending on the required evaluation item.
This product is suitable for medical device manufacturers, laboratories and quality control teams that need a reliable reference connector for male Luer connector verification.
Key Drawing Notes
Based on the ISO 80369-7 Figure C.1 drawing, this product should be identified as a female reference Luer lock connector for male Luer connector testing.
| Item | Figure C.1 Note |
|---|---|
| Figure Number | ISO 80369-7 Figure C.1 |
| Reference Connector Type | Female reference Luer lock connector |
| Test Object | Male Luer connectors |
| Typical Test Applications | Leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics |
| Key Interface | Female Luer lock reference interface |
| Dimension Unit | Millimetres unless otherwise indicated |
The final product page should only show confirmed dimensions from the product drawing or supplied datasheet. Material, hardness, dimensional report or documentation requirements can be confirmed before order placement.

How It Is Used and What It Tests
Typical Use Procedure
- Confirm that the sample is a male Luer connector and that ISO 80369-7 Figure C.1 is the required reference connector.
- Mate the male Luer sample with the Figure C.1 female reference Luer lock connector.
- Install the assembled connection into the required ISO 80369 test setup.
- Apply the specified leakage, unscrewing, stress cracking or non-interconnectability test condition.
- Record the result according to the selected test method.
- After testing, clean the connector and protect the reference interface from damage.
Typical Test Applications
The Figure C.1 connector is typically used in configurations related to:
- Leakage evaluation
- Separation from unscrewing
- Stress cracking evaluation
- Non-interconnectable characteristics
- Male Luer connector design verification
- Laboratory or factory quality control of Luer connector assemblies
The exact test condition should be confirmed according to the applicable test method and the customer’s sample structure.
Technical Features
- Designed according to ISO 80369-7 Figure C.1 reference connector geometry
- Female Luer lock reference interface for male Luer connector testing
- Suitable for ISO 80369-7 related leakage, unscrewing separation, stress cracking and non-interconnectability test configurations
- Precision-machined reference mating surface for repeatable connector engagement
- Hardened steel or stainless steel configuration can be supplied according to project requirements
- HRC58–62 hardness can be supplied where applicable and confirmed
- Available individually or as part of a complete ISO 80369-7 Luer Gauge Set
- Suitable for R&D validation, laboratory testing and factory quality control
- Can be used with suitable ISO 80369-20 leakage, air leakage or related test equipment
Operation and Handling Notes
The Figure C.1 connector should be handled as a precision reference component.
- Confirm the required figure number before testing.
- Do not replace Figure C.1 with Figure C.3 or Figure C.5 unless the selected procedure requires that configuration.
- Confirm whether the tested sample is a male Luer slip connector, male Luer lock connector or another specified male Luer configuration.
- Keep the female reference interface clean and free from scratches.
- Do not force the connector onto an incompatible sample.
- Avoid impact, corrosion or contamination during storage and use.
- Store the connector in a protective case after testing.
- Confirm documentation requirements before order placement if the connector will be used in a regulated laboratory environment.
Standards Compliance and Documentation Support
This ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is manufactured according to the Figure C.1 reference connector geometry for male Luer connector testing. It supports ISO 80369-7 related leakage, separation from unscrewing, stress cracking and non-interconnectable characteristic evaluations when used with the appropriate test setup.
KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.
Who Needs This Connector
| Customer Type | Typical Need |
|---|---|
| Syringe and needle manufacturers | Male Luer connector verification and quality control |
| IV cannula and infusion accessory manufacturers | Luer lock interface testing for medical connector assemblies |
| Medical device R&D teams | Design validation of male Luer connector structures |
| Third-party testing laboratories | ISO 80369-7 test setup preparation for customer samples |
| Factory QC laboratories | Incoming inspection and production batch checking |
| Certification support teams | Preparing suitable reference connectors before formal testing |
This page is intended for users who already know they need the Figure C.1 female reference Luer lock connector. Customers looking for a full ISO 80369-7 connector set should refer to the complete ISO 80369-7 Luer Gauge Set.
Compliance & Regulatory Assurance
The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is manufactured according to the Figure C.1 reference connector geometry for testing male Luer connectors. It supports ISO 80369-7 related leakage, separation from unscrewing, stress cracking and non-interconnectable characteristic evaluations when used with the appropriate test setup and procedure.
KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. If additional documentation is required for laboratory procurement or internal quality control, please confirm it before order placement.
|
Product Datasheet
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
Download the PDF datasheet for product overview, key drawing notes, operation notes and technical inquiry support.
|
Download Datasheet |
Technical Inquiry & Expert Support
The ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:
- Required product: ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
- Quantity required
- Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
- Your sample type, such as male Luer slip connector or male Luer lock connector
- Intended test application, such as leakage, separation from unscrewing, stress cracking or non-interconnectable characteristics
- Whether related ISO 80369-20 test equipment is also required
- Any documentation requirement, such as dimensional report, material information or hardness confirmation
KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.1 is the correct reference connector for your ISO 80369-7 test setup.
Related KINGPO ISO 80369 Products
| Related Product | Suggested Anchor Text |
|---|---|
| ISO 80369-7 Luer Gauge Set | ISO 80369-7 Luer Gauge Set |
| ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector | ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector |
| ISO 80369-7 Figure C.3 Female Reference Connector | ISO 80369-7 Figure C.3 Female Reference Connector |
| ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector | ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector |
| ISO 80369-7 Female Ring Gauge | ISO 80369-7 Female Ring Gauge |
| ISO 80369-20 Liquid Leakage Tester | ISO 80369-20 Liquid Leakage Tester |
| ISO 80369-20 Annex D Air Leakage Tester | ISO 80369-20 Annex D Air Leakage Tester |
| ISO 80369-20 Annex F Axial Load Tester | ISO 80369-20 Annex F Axial Load Tester |
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
FAQ
Related Products
Related News
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]