Front view of ISO 80369-7 Figure C.3 female reference connector for male Luer lock testing
ISO 80369-7 Figure C.3 female reference connector vertical view for male Luer lock connector testing
Side view of ISO 80369-7 Figure C.3 female reference connector
ISO 80369-7 Figure C.3 female reference connector drawing for male Luer lock connector testing
Front view of ISO 80369-7 Figure C.3 female reference connector for male Luer lock testing
ISO 80369-7 Figure C.3 female reference connector vertical view for male Luer lock connector testing
Side view of ISO 80369-7 Figure C.3 female reference connector
ISO 80369-7 Figure C.3 female reference connector drawing for male Luer lock connector testing

ISO 80369-7 Figure C.3 Female Reference Connector

The ISO 80369-7 Figure C.3 Female Reference Connector is a standard reference connector used for testing male Luer lock connectors in intravascular and hypodermic medical device applications. It provides the specified female reference interface for ISO 80369-7 related Luer lock connector evaluations.

  • Applicable Standard: ISO 80369-7 Figure C.3 / Annex C
  • Product Type: Female Reference Connector
  • Test Object: Male Luer lock connectors
  • Typical Use: Reference mating connector for ISO 80369-7 related Luer lock connector testing
  • Thread Note: Double-start, right-hand thread of 2.5 mm pitch
  • Important Limitation: Figure C.3 should be used only for the applicable test configuration and should not be treated as a universal female reference connector
  • Supply Option: Individual Figure C.3 connector or part of the complete ISO 80369-7 Luer Gauge Set
  • Related Equipment: Used with applicable ISO 80369-20 test setups when performance testing is required

Product Overview

ISO 80369-7 Figure C.3 Female Reference Connector

The ISO 80369-7 Figure C.3 Female Reference Connector is used as a controlled mating component when evaluating male Luer lock connectors. It should not be confused with the ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector, Figure C.5 Female Reference Luer Slip Connector, or the ISO 80369-7 Female Ring Gauge.

In a typical test setup, the male Luer lock connector sample is mated with the Figure C.3 female reference connector. The assembled connection is then used in the applicable ISO 80369 test procedure according to the required evaluation item and sample structure.

This page is intended for customers who specifically require Figure C.3 for a male Luer lock connector test configuration. Customers who need multiple ISO 80369-7 reference connectors should consider the complete ISO 80369-7 Luer Gauge Set.


Key Drawing Notes and Use Limitation

Figure C.3 has its own geometry and use limitation, so it should not be treated as interchangeable with C.1, C.5 or a female ring gauge. The official Figure C.3 drawing notes include a double-start right-hand thread and a specific limitation for certain non-interconnectable characteristic evaluations.

Item Figure C.3 Note
Figure Number ISO 80369-7 Figure C.3
Reference Connector Type Female reference connector
Test Object Male Luer lock connectors
Thread Note Double-start, right-hand thread of 2.5 mm pitch
Edge / Radius Note Radius or chamfer not to exceed 0.5 mm
Important Limitation This reference connector cannot be used for the test of non-interconnectable characteristics against its collar outside diameter because the corresponding defined range is wide and one single reference connector is not representative.
Dimension Unit Millimetres unless otherwise indicated

The Figure C.3 reference connector should be selected according to the required figure number and the test method. If the test item involves a specific collar outside diameter or non-interconnectable characteristic evaluation, the correct reference configuration should be confirmed before testing.

ISO 80369-7 Figure C.3 female reference connector drawing for male Luer lock connector testing


How It Is Used and What It Tests

Typical Use Procedure

  1. Confirm that the sample is a male Luer lock connector and that ISO 80369-7 Figure C.3 is the required reference connector.
  2. Mate the male Luer lock sample with the Figure C.3 female reference connector.
  3. Install the assembled connection into the applicable ISO 80369 test setup.
  4. Apply the required test condition according to the selected procedure.
  5. Record the result and inspect the connection according to the applicable test requirement.
  6. After testing, clean and protect the reference connector to avoid scratches, contamination or thread damage.

Typical Test Applications

The Figure C.3 connector is mainly used in ISO 80369-7 test configurations where a female reference connector is required for evaluating male Luer lock connectors. Typical applications may include:

  • Male Luer lock connector mating evaluation
  • Separation from unscrewing related test configurations
  • Resistance to overriding evaluation where applicable
  • Stress cracking related connector evaluation where the selected procedure requires Figure C.3
  • Non-interconnectable characteristic evaluation only when the test configuration allows this reference connector
  • Laboratory confirmation of male Luer lock connector fit and engagement

The exact test item should be confirmed according to the applicable ISO 80369-7 clause and ISO 80369-20 test method. The Figure C.3 connector itself is a reference connector, not a complete test apparatus.


Technical Features

  • Designed according to ISO 80369-7 Figure C.3 reference connector geometry
  • Female reference connector for male Luer lock connector testing
  • Threaded reference interface for Luer lock connector evaluation
  • Double-start, right-hand thread configuration according to the Figure C.3 drawing note
  • Precision-machined mating surface for repeatable connector engagement
  • Hardened steel or stainless steel configuration can be supplied according to the product specification.
  • Material information, dimensional confirmation or hardness confirmation can be provided where applicable.
  • Available individually or as part of the complete ISO 80369-7 Luer Gauge Set
  • Suitable for R&D validation, laboratory testing and factory quality control
  • Can be used with suitable ISO 80369-20 test equipment when performance testing is required

Operation and Handling Notes

The Figure C.3 connector should be handled as a precision reference component.

  • Confirm the required figure number before testing.
  • Do not replace Figure C.3 with Figure C.1, Figure C.5 or a female ring gauge unless the selected procedure clearly allows it.
  • Confirm whether the tested sample is a male Luer lock connector.
  • Check that the thread engagement is clean and free from visible damage.
  • Do not force the connector onto an incompatible or damaged sample.
  • Avoid impact, corrosion or contamination during storage and use.
  • Store the connector in a protective case after testing.
  • Confirm documentation requirements before order placement if the connector will be used in a regulated laboratory environment.

Compliance & Regulatory Assurance

This ISO 80369-7 Figure C.3 Female Reference Connector is manufactured according to the Figure C.3 reference connector geometry for male Luer lock connector testing. It supports ISO 80369-7 related connector evaluations when used with the appropriate test setup and procedure.

KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.

Product Datasheet

ISO 80369-7 Figure C.3 Female Reference Connector

Download the PDF datasheet for product overview, key drawing notes, use limitation, operation notes and technical inquiry support.
Download Datasheet

Technical Inquiry & Expert Support

The ISO 80369-7 Figure C.3 Female Reference Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:

  • Required product: ISO 80369-7 Figure C.3 Female Reference Connector
  • Quantity required
  • Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
  • Your sample type, especially male Luer lock connector
  • Intended test application, such as Luer lock mating evaluation, separation resistance or overriding resistance
  • Whether related ISO 80369-20 test equipment is also required
  • Any documentation requirement, such as dimensional report, material information or hardness confirmation

KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.3 is the correct reference connector for your ISO 80369-7 test setup.

Related KINGPO ISO 80369 Products

Related Product Suggested Anchor Text
ISO 80369-7 Luer Gauge Set ISO 80369-7 Luer Gauge Set
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector
ISO 80369-7 Female Ring Gauge ISO 80369-7 Female Ring Gauge
ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector
ISO 80369-20 Liquid Leakage Tester ISO 80369-20 Liquid Leakage Tester
ISO 80369-20 Annex D Air Leakage Tester ISO 80369-20 Annex D Air Leakage Tester
ISO 80369-20 Annex F Axial Load Tester ISO 80369-20 Annex F Axial Load Tester

ISO 80369-7 Figure C.3 Female Reference Connector

FAQ

When should I choose the ISO 80369-7 Figure C.3 Female Reference Connector?
Choose Figure C.3 when your test procedure specifically requires the ISO 80369-7 Figure C.3 female reference connector for evaluating male Luer lock connectors. It should not be selected only because the sample is a male Luer connector; the exact figure number should match the applicable test clause and connector configuration.
What is the main difference between Figure C.3 and Figure C.1?
Both are female reference connectors, but they are not interchangeable. Figure C.1 is identified as a female reference Luer lock connector for male Luer connectors, while Figure C.3 is a different female reference connector configuration used for male Luer lock connector testing. The correct choice depends on the required ISO 80369-7 figure and test method.
Can Figure C.3 replace Figure C.5?
No. Figure C.5 is a female reference Luer slip connector, while Figure C.3 is used for a different male Luer lock connector test configuration. If the test procedure calls for Figure C.5, using Figure C.3 may result in an incorrect mating condition and an invalid test setup.
Can this connector be used for non-interconnectable characteristic testing?
Only when the applicable procedure allows Figure C.3 for that evaluation. The Figure C.3 drawing includes an important limitation note, so it should not be treated as a universal reference connector for every non-interconnectable characteristic test. Confirm the required reference connector before testing.
Does the Figure C.3 connector perform leakage or separation testing by itself?
No. Figure C.3 is a reference connector, not a complete test apparatus. For leakage, separation, overriding resistance or other performance checks, it must be used together with the correct fixture, pressure source, force device or ISO 80369-20 related test equipment.
What sample information should we provide before ordering?
Please provide the sample type, especially whether it is a male Luer lock connector, the required ISO 80369-7 figure number, the intended test item, quantity required, and whether you need only the Figure C.3 connector or a complete ISO 80369-7 Luer gauge set.
Can KINGPO supply Figure C.3 as part of a complete ISO 80369-7 set?
Yes. Figure C.3 can be supplied individually or as part of the complete ISO 80369-7 C.1–C.6 Luer gauge set. The complete set is more suitable for laboratories that need to test several Luer slip and Luer lock connector configurations.
What documentation can be provided with this connector?
KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. If your laboratory requires specific documentation for procurement, internal quality control or test record purposes, please confirm this before order placement.

Related Products

Related News

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]

A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.
ISO 80369 test equipment checks medical connectors for compliance, preventing misconnections and ensuring patient safety in healthcare environments.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Scroll to Top