Side view of ISO 80369-7 Figure C.5 female reference Luer slip connector
Angled view of ISO 80369-7 Figure C.5 female reference Luer slip connector
Vertical view of ISO 80369-7 Figure C.5 female reference Luer slip connector
ISO 80369-7 Figure C.5 female reference Luer slip connector drawing for male Luer connector testing
Side view of ISO 80369-7 Figure C.5 female reference Luer slip connector
Angled view of ISO 80369-7 Figure C.5 female reference Luer slip connector
Vertical view of ISO 80369-7 Figure C.5 female reference Luer slip connector
ISO 80369-7 Figure C.5 female reference Luer slip connector drawing for male Luer connector testing

ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector

The ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector is a standard reference connector used for testing male Luer connectors in intravascular and hypodermic medical device applications. It provides the specified female Luer slip reference interface for ISO 80369-7 related leakage, separation from axial load, stress cracking and non-interconnectable characteristic evaluations.

  • Applicable Standard: ISO 80369-7 Figure C.5 / Annex C
  • Product Type: Female Reference Luer Slip Connector
  • Test Object: Male Luer connectors
  • Typical Test Applications: Leakage, separation from axial load, stress cracking and non-interconnectable characteristics
  • Connector Type: Female reference Luer slip connector
  • Cone Taper: 0.06:1 according to the Figure C.5 drawing
  • Important Note: Figure C.5 has specific taper length and non-interconnectable characteristic limitations
  • Supply Option: Individual Figure C.5 connector or part of the complete ISO 80369-7 Luer Gauge Set
  • Related Equipment: Used with applicable ISO 80369-20 test setups when performance testing is required

Product Overview

ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector

The ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector is used as a controlled mating component when evaluating male Luer connectors. It is designed for test configurations that require a female Luer slip reference interface, and should not be confused with the ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector or the ISO 80369-7 Female Ring Gauge.

This page corrects the previous ISO 80369-20 page classification. The product is not an ISO 80369-20 test apparatus; it is an ISO 80369-7 Annex C reference connector that may be used together with appropriate ISO 80369-20 related test setups when leakage, axial load separation or other performance checks are required.

Customers who already know they need Figure C.5 can order this connector individually. Laboratories that test several Luer slip and Luer lock connector configurations may consider the complete ISO 80369-7 Luer Gauge Set.


Key Drawing Notes and Use Limitation

Based on the ISO 80369-7 Figure C.5 drawing you provided, this reference connector is identified as a female reference Luer slip connector for testing male Luer connectors. The drawing also includes taper length notes and a limitation for certain non-interconnectable characteristic evaluations.

Item Figure C.5 Note
Figure Number ISO 80369-7 Figure C.5
Reference Connector Type Female reference Luer slip connector
Test Object Male Luer connectors
Cone Taper 0.06:1
Taper Length Note Minimum taper length of 10.5 mm is required for non-interconnectable characteristic testing; minimum 7.5 mm may be used for Clause 6 performance tests
Edge / Radius Note R is a radius or chamfer not to exceed 0.5 mm
Important Limitation This reference connector cannot be used for the test of non-interconnectable characteristics against its collar outside diameter because the corresponding defined range is wide and one single reference connector is not representative
Dimension Unit Millimetres unless otherwise indicated

ISO 80369-7 Figure C.5 female reference Luer slip connector drawing for male Luer connector testing

 R is a radius or chamfer not to exceed 0,5 mm.
Theminimumlengthof themaletaperof10,5mmisrequired for testingnon-interconnectablecharacteristics.A minimum length of the male taper of 7,5 mm can be used for the performance tests of Clause 6.

  • NOTE  1     Cone taper (0,06:1).
  • NOTE 2     This referenceconnectorcannotbe used for thetestofnon-interconnectable characteristics againstits collar outsidediameterbecause itscorresponding defined range[OI) is wideand onesingle referenceconnector is not representative.

Figure C.5 – Female reference Luer slip connector for testing male Luer connectors for leakage, separation from axial load, stress cracking and non-interconnectable characteristics


How It Is Used and What It Tests

Typical Use Procedure

  1. Confirm that the sample is a male Luer connector and that ISO 80369-7 Figure C.5 is the required reference connector.
  2. Mate the male Luer sample with the Figure C.5 female reference Luer slip connector.
  3. Install the assembled connection into the applicable ISO 80369 test setup.
  4. Apply the required leakage, axial load separation, stress cracking or non-interconnectability test condition.
  5. Record the result according to the selected test procedure.
  6. After testing, clean and protect the reference connector to avoid scratches, contamination or deformation.

Typical Test Applications

The Figure C.5 connector may be used in ISO 80369-7 test configurations related to:

  • Male Luer connector evaluation
  • Luer slip mating interface verification
  • Leakage-related test configurations
  • Separation from axial load related test configurations
  • Stress cracking related connector evaluation
  • Non-interconnectable characteristic evaluation only when the selected procedure allows this reference connector
  • Laboratory confirmation of male Luer connector fit and engagement

The exact test item, pressure, axial load, holding time and judgment criteria should be confirmed according to the applicable ISO 80369-7 clause and ISO 80369-20 related test method. The Figure C.5 connector itself is a reference connector, not a complete test apparatus.


Technical Features

  • Designed according to ISO 80369-7 Figure C.5 reference connector geometry
  • Female reference Luer slip interface for male Luer connector testing
  • 0.06:1 cone taper according to the Figure C.5 drawing
  • Precision-machined mating surface for repeatable connector engagement
  • Suitable for ISO 80369-7 related leakage, axial load separation, stress cracking and non-interconnectability test configurations
  • Hardened steel or stainless steel configuration can be supplied according to product specification
  • Material information, dimensional confirmation or hardness confirmation can be provided where applicable
  • Available individually or as part of the complete ISO 80369-7 Luer Gauge Set
  • Suitable for R&D validation, laboratory testing and factory quality control
  • Can be used with suitable ISO 80369-20 test equipment when performance testing is required

Operation and Handling Notes

The Figure C.5 connector should be handled as a precision reference component.

  • Confirm the required figure number before testing.
  • Do not replace Figure C.5 with Figure C.1 or Figure C.3 unless the selected procedure clearly requires that configuration.
  • Confirm whether the tested sample is a male Luer connector.
  • Keep the female Luer slip reference interface clean and free from visible scratches.
  • Do not force the connector onto an incompatible or damaged sample.
  • Avoid impact, corrosion or contamination during storage and use.
  • Store the connector in a protective case after testing.
  • Confirm documentation requirements before order placement if the connector will be used in a regulated laboratory environment.

Who Needs This Connector

Customer Type Typical Need
Male Luer connector manufacturers Male Luer connector verification using a female Luer slip reference connector
Syringe and needle manufacturers Luer slip connector evaluation for medical device assemblies
IV cannula and infusion accessory manufacturers Connector mating and leakage-related test configuration
Medical device R&D teams Design validation of male Luer connector structures
Third-party testing laboratories ISO 80369-7 reference connector setup for customer samples
Factory QC laboratories Incoming inspection and production batch checking
Certification support teams Preparing suitable reference connectors before formal testing

Compliance & Regulatory Assurance

This ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector is manufactured according to the Figure C.5 reference connector geometry for male Luer connector testing. It supports ISO 80369-7 related connector evaluations when used with the appropriate test setup and procedure.

KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.

Product Datasheet
ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector
Download the PDF datasheet for product overview, key drawing notes, use limitation, operation notes and technical inquiry support.
Download Datasheet

Technical Inquiry & Expert Support

The ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:

  • Required product: ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector
  • Quantity required
  • Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
  • Your sample type, especially male Luer connector
  • Intended test application, such as leakage, separation from axial load, stress cracking or non-interconnectable characteristics
  • Whether related ISO 80369-20 test equipment is also required
  • Any documentation requirement, such as dimensional report, material information or hardness confirmation

KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.5 is the correct reference connector for your ISO 80369-7 test setup.

Difference from Related ISO 80369-7 Gauges

Related Product Difference
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector Female Luer lock reference connector for male Luer connector testing
ISO 80369-7 Figure C.3 Female Reference Connector Female reference connector for male Luer lock connector testing in another configuration
ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector Female Luer slip reference connector for testing male Luer connectors
ISO 80369-7 Female Ring Gauge Dimensional ring gauge; not the same as the Figure C.5 reference connector
ISO 80369-7 Male Plug Gauge Dimensional or fit-checking gauge; not the same as Figure C.5
ISO 80369-7 Luer Gauge Set Complete C.1–C.6 reference connector set
ISO 80369-20 Test Equipment Test apparatus used to apply leakage, air leakage, axial load or related test conditions

This distinction helps customers avoid using a Luer lock reference connector, a female ring gauge, or another female reference connector when Figure C.5 is specifically required.

ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector

FAQ

When should I choose ISO 80369-7 Figure C.5?
Choose Figure C.5 when your test procedure specifically requires a female reference Luer slip connector for testing male Luer connectors. It should not be selected only because the sample is a male Luer connector; the exact figure number must match the applicable ISO 80369-7 test configuration.
What is the difference between Figure C.5 and Figure C.1?
Both are female reference connectors for male Luer connector testing, but they are not interchangeable. Figure C.5 is a female reference Luer slip connector, while Figure C.1 is a female reference Luer lock connector. The correct choice depends on the required mating interface and test procedure.
What is the difference between Figure C.5 and Figure C.3?
Figure C.3 is used for male Luer lock connector testing in another female reference connector configuration. Figure C.5 is specifically a female reference Luer slip connector. Using the wrong figure may create an incorrect mating condition and affect the validity of the test setup.
Is Figure C.5 the same as a female ring gauge?
No. Figure C.5 is an ISO 80369-7 Annex C reference connector used in test configurations. A female ring gauge is generally used for dimensional or fit checking. They serve different purposes and should not be treated as the same product.
Can Figure C.5 be used for every non-interconnectable characteristic test?
No. The Figure C.5 drawing includes a limitation for certain non-interconnectable characteristic evaluations. It should not be treated as a universal reference connector. The required reference connector and test configuration should be confirmed before testing.
Does this connector perform leakage testing by itself?
No. Figure C.5 is a reference connector, not a complete leakage tester. For leakage or other performance tests, it must be used with the appropriate fixture, pressure source, measuring device and ISO 80369-20 related test procedure.
Can Figure C.5 be supplied as part of a complete ISO 80369-7 set?
Yes. The Figure C.5 connector can be supplied individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set. The full set is suitable for laboratories that test multiple Luer slip and Luer lock connector configurations.
What information should be provided before ordering?
Please provide the required product name, quantity, sample connector type, intended test application and documentation requirements. If you are not sure whether Figure C.5, C.1 or C.3 is required, KINGPO can help review the connector type and test purpose before quotation.

Related Products

Related News

KingPo supplied ISO 80369-7 Luer Gauges to ООО «АнгиоСистемы» (AngioSystems LLC) in Russia. The gauges are used for laboratory testing of […]

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.
ISO 80369 test equipment checks medical connectors for compliance, preventing misconnections and ensuring patient safety in healthcare environments.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.