ISO 80369-7 Male Plug Gauge for Testing Female Luer Connectors
ISO 80369-7 Male Plug Gauge for Testing Female Luer Connectors

ISO 80369-7 Male Plug Gauge for Testing Female Luer Connectors

ISO 80369-7 Male Plug Gauge performs precise testing of female Luer connectors for medical device safety compliance.

  • Hardened steel construction: HRC58-62 hardness for long-term dimensional stability
  • Precision luer taper: exact 6% (0.06:1) conical profile as defined in ISO 80369-7
  • Dimensional accuracy: calibrated to verify female Luer connector geometry and interconnectability
  • Multiple test functions: supports leakage, axial load separation, stress cracking and non-interconnectable tests
  • Compact and durable design: suitable for laboratory and production quality control use
  • MOQ: 1
  • Delivery Period: 7 working days

ISO 80369-7 Male Plug Gauge Description

ISO 80369-7 Male Plug Gauge โ€“ Precision Gauge for Testing Female Luer Connectors

The ISO 80369-7 Male Plug Gauge is a high-precision reference tool designed to verify the dimensional accuracy and functional performance of female Luer connectors used in intravascular and hypodermic medical applications. Manufactured in accordance with ISO 80369-7, the gauge ensures connectors meet strict requirements for leakage prevention, separation resistance, stress cracking resistance and non-interconnectability, thereby enhancing patient safety by reducing the risk of dangerous misconnections.

Testing Principle

The male plug gauge is inserted into the female Luer connector under controlled conditions to check critical dimensions, taper angle and sealing performance. It is used to perform functional tests including leakage, axial load separation, stress cracking and non-interconnectable characteristics as specified in ISO 80369-7, providing repeatable and traceable verification results.

KingPo Factory Advantages

KingPo is an ISO 9001, ISO 14001, ISO 45001 and CE certified manufacturer, also holding SGS, PSE and RoHS certifications. We specialize in medical device testing equipment and have supplied ISO 80369-7 male plug gauges to manufacturers and certification laboratories worldwide. Each unit undergoes rigorous calibration and is delivered with complete documentation, on-site installation guidance, a full one-year warranty and lifetime technical support from our Dongguan facility.

Professional Construction & Technical Precision

Key features include:

  • Hardened steel material with HRC58-62 hardness for maximum wear resistance and long-term dimensional stability
  • Exact 6% (0.06:1) luer taper machined to ISO 80369-7 tolerances for accurate verification
  • Precision-machined geometry ensuring repeatable test results for leakage, separation and interconnectability
  • Robust and compact design suitable for daily laboratory and production quality control use
  • ISO 17025 calibration certificate available to maintain traceability

These elements ensure the gauge delivers consistent, reliable and standard-compliant testing results for female Luer connectors.

Technical Parameters

Parameter Specification Remark / Notes
Standard ISO 80369-7 Male reference plug gauge for female Luer connectors
Material Hardened steel HRC58-62 hardness
Taper 6% (0.06:1) conical profile Exact ISO 80369-7 geometry
Test Functions Leakage, axial load separation, stress cracking, non-interconnectable Full compliance verification
Calibration ISO 17025 available Traceable certificate optional

 

Primary Use Cases & Business Value

The ISO 80369-7 Male Plug Gauge is used to verify dimensional accuracy and functional performance of female Luer connectors during product development, production quality control and third-party certification. It helps manufacturers ensure connectors meet international safety requirements, reduce the risk of misconnections and maintain compliance with medical device regulations.

Procurement Benefits

The gauge offers precision-machined geometry, hardened steel construction and full ISO 80369-7 compliance in a compact, durable design. It provides consistent, repeatable test results with minimal maintenance, making it a practical solution for Luer connector testing.

ISO 80369-7 Male Plug Gauge Applications

  • Female Luer connectors โ€“ dimensional and functional verification for intravascular and hypodermic applications
  • Medical device manufacturers โ€“ quality control of connectors for syringes, needles and infusion sets
  • Certification laboratories โ€“ compliance testing according to ISO 80369-7
  • R&D departments โ€“ optimization of connector design and sealing performance

Compliance & Regulatory Assurance

This equipment is designed and manufactured in accordance with ISO 80369-7 for male reference plug gauges used in testing female Luer connectors. It provides a standardized method to verify leakage, separation, stress cracking and non-interconnectable characteristics, ensuring connectors meet the required safety and performance levels for medical applications.

For detailed information on small-bore connectors, please refer to the latest edition of ISO 80369-7.

Regular verification of gauge dimensions is recommended to maintain traceability.

Technical Inquiry for ISO 80369-7 Male Plug Gauge

KingPo specializes in medical device testing equipment. If you require precise ISO 80369-7 male plug gauges for female Luer connector testing, our engineering team can provide technical support and configuration recommendations.

The Core Value We Deliver to You

  • Hardened steel with HRC58-62 for long-term dimensional stability
  • Exact 6% luer taper machined to ISO 80369-7 tolerances
  • Supports full range of leakage, separation and interconnectability tests
  • Compact and durable design for laboratory and production use
  • ISO 17025 calibration certificate available

Tell us your connector type or test requirements โ€” our engineering team will reply with tailored recommendations within 24 hours.

ISO 80369-7 Male Plug Gauge FAQs

What is the purpose of the ISO 80369-7 Male Plug Gauge?
The ISO 80369-7 Male Plug Gauge verifies dimensional accuracy and functional performance of female Luer connectors for leakage, separation, stress cracking and non-interconnectable characteristics.
Which standard does this male plug gauge comply with?
The gauge complies with ISO 80369-7 for testing female Luer connectors used in intravascular and hypodermic medical applications.
What material is used for the ISO 80369-7 male plug gauge?
It is manufactured from hardened steel with HRC58-62 hardness for maximum wear resistance and long-term dimensional stability.
What is the taper specification of the male plug gauge?
The gauge features the exact 6% (0.06:1) conical taper as defined in ISO 80369-7 for accurate verification of female Luer connectors.
Can the male plug gauge be used for multiple test functions?
Yes. It supports leakage, axial load separation, stress cracking and non-interconnectable tests as required by ISO 80369-7.
Is the gauge suitable for production quality control?
Yes. Its precision-machined geometry and durable construction make it ideal for daily laboratory and production line verification of female Luer connectors.
What calibration options are available for the ISO 80369-7 male plug gauge?
ISO 17025 calibration certificates are available to ensure traceability and compliance with medical device quality systems.
How accurate is the dimensional control of the male plug gauge?
The gauge is machined to exact ISO 80369-7 tolerances, ensuring repeatable and reliable test results for female Luer connectors.
What medical applications require this male plug gauge?
It is widely used for testing female Luer connectors in syringes, needles, infusion sets and other intravascular or hypodermic medical devices.
How can I request a quotation for the ISO 80369-7 Male Plug Gauge?
Provide your connector type or specific test requirements; our engineering team will return a competitive quotation within 24 hours.

Related Products

Related News

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.

How to Troubleshoot Common Faults in Water Pump Testing Equipment: Practical Operation Guide for ISO 9906 Compliance   Introduction Operators […]

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

ISO 5356-1:2015 is the internationally recognized standard titled Anaesthetic and respiratory equipment โ€” Conical connectors โ€” Part 1: Cones and […]

A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.