E27 Lamp Cap Gauge 7006-51-2 Overall View โ€“ IEC 60061-3 Protection Against Accidental Contact Gauge
E27 Lamp cap gauge Gauge For Caps on Finished Lamps for Testing Protection Against Accidental Contact E27 7006-51-2
E27 Lamp Cap Gauge 7006-51-2 Overall View โ€“ IEC 60061-3 Protection Against Accidental Contact Gauge
E27 Lamp cap gauge Gauge For Caps on Finished Lamps for Testing Protection Against Accidental Contact E27 7006-51-2

E27 Lamp Cap Gauge 7006-51-2 | IEC 60061-3 Protection Against Accidental Contact Gauge

E27 Lamp Cap Gauge for precise IEC 60061-3 testing of protection against accidental contact on finished E27 lamps. Hardened steel Go/No-Go gauge (7006-51-2) ensures electrical safety compliance with repeatable, reliable results.

  • Standard Compliance: Fully compliant with IEC 60061-3, code 7006-51-2 for protection against accidental contact testing
  • Precision Gauge Design: Specialized Go/No-Go gauge for E27/51ร—39 caps on finished lamps
  • Material: Premium hardened steel (HRC 58โ€“60) for exceptional wear resistance and long-term dimensional stability
  • Testing Function: Clear visual pass/fail verification of lamp cap geometry and live-part accessibility
  • Testing Principle: Lamp fully inserted; surface W must not protrude beyond surface V
  • Construction: Precision-machined surfaces manufactured to strict IEC tolerances
  • Ease of Use: Compact handheld design for fast laboratory or production-line inspection
  • MOQ: 1 set
  • Delivery Time: 7 working days

E27 Lamp Cap Gauge Description

E27 Lamp Cap Gauge 7006-51-2 | IEC 60061-3 Protection Against Accidental Contact Gauge

The E27 Lamp Cap Gauge is a specialized precision measuring instrument engineered to evaluate protection against accidental contact of E27/51ร—39 lamp caps on finished lamps in accordance with IEC 60061-3. It offers manufacturers, quality control teams, and certification laboratories a reliable, repeatable solution to confirm that no live electrical parts are accessible during normal handling or installation, thereby preventing electric shock hazards and supporting global safety certifications for LED, CFL, halogen, and other E27-based lighting products.

E27 Lamp cap gauge Gauge For Caps on Finished Lamps for Testing Protection Against Accidental Contact E27 7006-51-2
E27 Lamp cap gauge | Gauge For Caps on Finished Lamps for Testing Protection Against Accidental Contact E27 | 7006-51-2

Technical Parameters

Item Specification Remark / Notes
Applicable Standard IEC 60061-3, Code 7006-51-2 Protection against accidental contact
Gauge Type Go/No-Go for finished lamps Specifically designed for E27/51ร—39 caps
Cap Designation E27/51ร—39 For caps mounted on completed lamps
Material Hardened steel HRC 58โ€“60 for maximum durability and wear resistance
Hardness HRC 58โ€“60 Ensures dimensional stability over thousands of cycles
Testing Method Lamp insertion check Surface W must not protrude beyond surface V
Application Finished E27 lamps only LED, CFL, halogen, and similar lighting products
Construction Precision machined surfaces Manufactured to strict IEC 60061-3 tolerances
Portability Handheld, compact design Ideal for production line and laboratory use
Calibration Factory traceable certificate ISO 17025 accreditation available upon request

 

Professional Construction & Technical Precision

The E27 Lamp Cap Gauge is precision-manufactured from premium-grade hardened steel with a controlled hardness of HRC 58โ€“60, delivering superior wear resistance and exceptional long-term dimensional stability even after thousands of inspection cycles. Every critical surface is CNC-machined to the exacting tolerances specified in IEC 60061-3, ensuring consistent Go/No-Go performance across high-volume production environments.

Its compact, ergonomic handheld design allows operators to perform rapid, fatigue-free testing directly on the production line or in the laboratory. The clearly defined reference surfaces (V and W) provide instant visual confirmation of results, eliminating the need for secondary measuring instruments and streamlining the entire verification process.

Testing Principle

The E27 Lamp Cap Gauge evaluates protection against accidental contact by precisely replicating real-world user interaction with a finished lamp. The completed E27 lamp is inserted fully into the gauge until it reaches its natural stopping point. According to IEC 60061-3 (code 7006-51-2), the test is considered passed if surface W of the lamp cap does not protrude beyond surface V of the gauge.

This straightforward yet highly effective method confirms that no live electrical parts are accessible during normal handling or installation, significantly reducing the risk of electric shock and ensuring the lamp meets international safety requirements for consumer and commercial lighting applications.

Common Error Mitigation

To achieve consistently accurate and fully standards-compliant results with the E27 Lamp Cap Gauge, operators are recommended to follow these best practices:

  • Thoroughly clean the gauge before each use to eliminate any debris, dust, or residue that could affect measurement accuracy.
  • Insert the lamp cap smoothly and fully until it stops naturallyโ€”never apply excessive force or tilt the lamp.
  • Visually verify that surface W remains flush with or below surface V under proper lighting conditions.
  • Conduct periodic dimensional verification and recalibration in accordance with IEC guidelines to maintain long-term precision.
  • Maintain comprehensive test records, including lamp model, batch number, date, and pass/fail outcome, to support full traceability and audit compliance.
Precision E27 Lamp Cap Gauge 7006-51-2 โ€“ Hardened Steel Go/No-Go Gauge IEC 60061-3
Precision E27 Lamp Cap Gauge 7006-51-2

Primary Use Cases & Business Value

The E27 Lamp Cap Gauge serves as an essential quality control instrument for verifying the electrical safety of E27 lamps throughout every stage of the product lifecycle. It empowers manufacturers to detect cap design or manufacturing deviations at the earliest possible point, dramatically accelerating compliance testing while minimizing the potential for costly field failures or product recalls.

By delivering reliable, repeatable results with minimal training required, this gauge helps companies enhance overall product quality, shorten time-to-market, and strengthen customer confidence in their lighting solutions across global markets.

Industrial Applications & Lab Scenarios

  • Lighting Manufacturers โ€” Final safety inspection of finished E27 LED, CFL, and halogen lamps prior to shipment
  • Quality Control Departments โ€” High-volume in-line and batch testing of lamp caps on automated production lines
  • Third-Party Certification Laboratories โ€” IEC 60061-3 type approval, regulatory verification, and compliance reporting
  • R&D Teams โ€” Rapid validation of new lamp cap designs and ongoing safety performance improvements

Strategic Procurement Advantages & Global Support

  • Precise verification of protection against accidental contact using the official IEC 60061-3 7006-51-2 specification
  • Robust hardened steel construction guarantees years of maintenance-free, high-accuracy service
  • Intuitive handheld operation that supports fast, high-throughput production environments
  • Manufactured under ISO 9001 certified quality management with responsive technical support and full customization capabilities

Compliance & Regulatory Assurance

The E27 Lamp Cap Gauge is engineered and manufactured in complete accordance with the IEC 60061-3 standard for protection against accidental contact testing. It provides lighting manufacturers and accredited laboratories with a standardized, traceable solution that fully satisfies the most stringent international electrical safety regulations for E27 series lighting products.

Metrological Integrity & Validation

  • Complimentary Factory Calibration: Every gauge ships with a detailed traceable calibration certificate as standard.
  • Third-party ISO 17025 Accreditation: Available upon request to meet the requirements of certification bodies and regulatory authorities.
  • Performance Verification: Regular dimensional inspection is strongly recommended to ensure sustained measurement accuracy over the equipmentโ€™s entire service life.

Technical Inquiry & Expert Support

Contact our engineering team for custom E27 series gauges, complete lamp cap gauge sets, or seamless integration with other IEC 60061-3 test instruments. Professional technical recommendations and detailed quotations are provided within 24 hours.

The Core Value We Deliver

  • Accurate and repeatable protection against accidental contact testing with the E27 Lamp Cap Gauge
  • Premium hardened steel construction engineered for precision and exceptional longevity
  • Simple, efficient handheld solution optimized for E27 lamp safety verification
  • Comprehensive support for lighting industry compliance, quality assurance, and successful global market access

Lamp Cap & Lampholder Standard Gauge List (IEC 7006 Series)

Technical Compliance & Support:

All the followingย Lamp Cap and Lampholder Gaugesย are engineered in strict accordance withย IEC 60061-3,ย IEC 60968, andย IEC 60238ย standards. KingPo providesย full customization servicesย for all specifications listed below. To ensure laboratory-grade accuracy and regulatory compliance, each unit is delivered with aย Complimentary Factory Calibration Certificate, and third-partyย ISO 17025 accredited calibration reportsย are available upon request.

No. Category Name Standard Figure
1 E14 Lamp Cap E14 Lamp Cap โ€œGoโ€ Gauge 7006-27F-1
2 E14 Lamp Cap E14 Lamp Cap โ€œNot Goโ€ Gauge 7006-28B-1
3 E14 Lamp Cap E14 Lamp Cap Prevent Accidental Contact Gauge 7006-55-2
4 E14 Lamp Cap E14S1 Lamp Cap โ€œGoโ€ Gauge 7006-27G-1
5 E14 Lamp Cap E14 Lamp Cap Contact Making Gauge 7006-54-2
6 E14 Lamp Cap E14 Lamp Cap Torque Test Gauge IEC60968 Fig2
7 E27 Lamp Cap E27 Lamp Cap โ€œGoโ€ Gauge 7006-27B-1
8 E27 Lamp Cap E27 Lamp Cap โ€œNot Goโ€ Gauge 7006-28A-1
9 E27 Lamp Cap E27S1 Lamp Cap โ€œGoโ€ Gauge 7006-27C-1
10 E27 Lamp Cap E27 Lamp Cap Contact Making Gauge 7006-50-1
11 E27 Lamp Cap E27 Lamp Cap Prevent Accidental Contact Gauge 7006-51A-2
12 E27 Lamp Cap E27 Lamp Cap Prevent Accidental Contact Gauge 51*39 7006-51-2
13 E27 Lamp Cap E27 Lamp Cap Torque Test Gauge IEC60968 Fig2
14 B15 Lamp Cap B15 Lamp Cap Insertion Gauge 7006-4A-2
15 B15 Lamp Cap B15 Lamp Cap Retention Gauge 7006-4B-1
16 B15 Lamp Cap B15 Lamp Cap โ€œNot Goโ€ Gauge 7006-10-8
17 B15 Lamp Cap B15 Lamp Cap โ€œGoโ€ Gauge 7006-11-8
18 B15 Lamp Cap B15 Lamp Cap Torque Test Gauge IEC60968 Fig3
19 B22d Lamp Cap B22 Lamp Cap Insertion Gauge 7006-4A-2
20 B22d Lamp Cap B22 Lamp Cap Retention Gauge 7006-4B-1
23 B22d Lamp Cap B22 Lamp Cap โ€œGoโ€ Gauge 7006-10-8
24 B22d Lamp Cap B22 Lamp Cap โ€œNot Goโ€ Gauge 7006-11-8
25 B22d Lamp Cap B22D Lamp Cap Acceptance Gauge 7006-3-1
26 BY22d Lamp Cap BY22d Lamp Cap โ€œGoโ€ Gauge 7006-17A-1
27 B22d Lamp Cap B22 Lamp Cap Torque Test Gauge IEC60968 Fig3
28 GZ10 Lamp Cap โ€œGoโ€ / โ€œNot Goโ€ Gauge 7006-120-1
29 GZ10 Lamp Holder โ€œGoโ€ / โ€œNot Goโ€ Gauge 7006-120A-1
30 GU10 Lamp Holder โ€œGoโ€ / โ€œNot Goโ€ Gauge 7006-121A-1
31 GU10 Lamp Cap GU10 Lamp Cap โ€œGoโ€ / โ€œNot Goโ€ Gauge 7006-121-1
32 E26 Lamp Cap E26 Lamp Cap โ€œGoโ€ Gauge 7006-27D-3
33 E26 Lamp Cap E26 Lamp Cap โ€œNot Goโ€ Gauge 7006-29L-4
34 E26 Lamp Cap E26d Lamp Cap Prevent Accidental Contact Gauge 7006-29A-2
35 E26 Lamp Cap E26 Lamp Cap Contact Making Gauge 7006-29-3
36 E26 Lamp Cap E26d Lamp Cap Reference Diameter 23mm โ€œGoโ€ Gauge 7006-29B-2
37 E26 Lamp Cap E26d Lamp Cap Reference Diameter 13.2mm โ€œGoโ€ Gauge 7006-29C-2
38 E26 Lamp Cap E26d Lamp Cap Reference Diameter 10.4mm โ€œGoโ€ Gauge 7006-29D-1
39 E26 Lamp Cap Lamp Cap Gauge 7006-27E-1
40 E14 Lamp Holder โ€œGoโ€ Gauge 7006-25-7
41 E14 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
42 E14 Lamp Holder Contact Making Gauge 7006-30-2
43 E14 Lamp Holder Candle Lamp Contact Making Gauge 7006-30A-1
43 E14 Lamp Holder Prevent Accidental Contact Gauge 7006-31-4
44 E14 Lamp Holder Torque Test Cap IEC 60238 Figure5
45 E14 Lamp Holder Test Cap โ€œAโ€ IEC 60238 Figure13
46 E14 Lamp Holder Test Cap โ€œbโ€ IEC 60238 Figure13
47 E27 Lamp Holder โ€œGoโ€ Gauge 7006-25A-2
48 E27 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
49 E27 Lamp Holder Prevent Accidental Contact Gauge 7006-22A-4
50 E27 Lamp Holder Anti-bulb Neck Damage and Contact Making Gauge 7006-21-5
51 E27 Lamp Holder Inside Shrapnel Resilience Gauge 7006-22D-1
52 E27 Lamp Holder Side Contacts Edge Gauge 7006-22B-1
53 E27 Lamp Holder Side Contacts Resilience Gauge 7006-22C-1
54 E27 Lamp Holder Torque Test Cap IEC 60238 Figure5
55 E27 Lamp Holder Aging Test Cap IEC 60238 Figure14
56 E40 Lamp Cap โ€œGoโ€ Gauge 7006-27-7
57 E40 Lamp Cap โ€œNot Goโ€ Gauge 7006-28D-1
58 E40 Lamp Cap Prevent Accidental Contact Gauge 7006-53-1
59 E40 Lamp Cap Contact Making Gauge 7006-52-1
60 B22 Lamp Holder Plug Gauge 7006-12-8
61 B22 Lamp Holder Gauge for checking contact position and contact force (90ยฐ-130ยฐ) 7006-15-7
62 B22 Lamp Holder Gauge for checking contact position and contact force (90ยฐ-130ยฐ) 7006-20-4
63 B22 Lamp Holder Supplementary โ€œGoโ€ Gauge 7006-12A-2
64 B22 Lamp Holder โ€œNot Goโ€ / Retention Gauge 7006-12B-2
65 B22 Lamp Holder Gauge for checking contact position and contact force 7006-15A-2
66 B22 Lamp Holder Gauge for the slots in lampholders 7006-13-5
67 B22 Lamp Holder Plug Gauge 7006-17B-1
68 E12 Lamp Cap โ€œGoโ€ Gauge 7006-27H-1
69 E12 Lamp Cap โ€œNot Goโ€ Gauge 7006-28C-1
70 E12 Lamp Cap Supplementary โ€œGoโ€ Gauge 7006-27J-1
71 E12 Lamp Cap Contact Making Gauge 7006-32-1
72 E17 Lamp Cap โ€œGoโ€ Gauge 7006-27K-1
73 E17 Lamp Cap โ€œNot Goโ€ Gauge 7006-28F-1
74 E17 Lamp Cap Contact Making Gauge 7006-26D-1
75 E39 Lamp Cap โ€œGoโ€ Gauge 7006-24B-1
76 E39 Lamp Cap โ€œNot Goโ€ Gauge 7006-24C-1
77 E39 Lamp Cap Contact Making Gauge 7006-24A-1
78 E40 Lamp Holder โ€œGoโ€ Gauge 7006-25-7
79 E40 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
80 E40 Lamp Holder Prevent Accidental Contact Gauge 7006-24-3
81 E40 Lamp Holder Contact Making Gauge 7006-23-3
82 1EP10 Lamp Cap โ€œNot Goโ€ Gauge 7006-28-7
83 2EP10 Lamp Cap โ€œGoโ€ Gauge 7006-37-1
84 3EY10 Lamp Cap โ€œGoโ€ Gauge 7006-7-1
85 4E10 Lamp Cap โ€œGoโ€ Gauge 7006-27A-2
86 G5 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge for Unfinished Bi-pin Cap 7006-46-3
87 G5 Lamp Cap โ€œGoโ€ Gauge for Bi-pin Cap on Finished Lamps 7006-46A-3
88 G13 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge for Unfinished Bi-pin Cap 7006-44-4
89 G13 Lamp Cap โ€œGoโ€ Gauge for Bi-pin Cap on Finished Lamps 7006-45-4
90 G5 Lamp Holder Contact Making Plug Gauge for Finished Lamps 7006-47A-2
91 G5 Lamp Holder Double Ended Gauge 7006-47B-3 III IV V
92 G5 Lamp Holder Double Ended โ€œGoโ€ Gauge 7006-47B-3 I II
93 G13 Lamp Holder Double Ended Gauge 7006-60B-4 III IV V
94 G13 Lamp Holder Double Ended โ€œGoโ€ Gauge 7006-60C-3 I II
95 GU5.3 Lamp Holder โ€œGoโ€ Gauge 7006-73A-1
96 GU5.3 Lamp Holder Gauge A 7006-73A-2
97 GU5.3 Lamp Holder Gauge B 7006-126B-1
98 G9 Lamp Cap โ€œGoโ€ Gauge 7006-129-1
99 G9 Lamp Cap โ€œNot Goโ€ Gauge 7006-129A-1
100 G5.3 Lamp Cap Gauge for Bi-pin Cap G5.3 on Finished Lamps 7006-73-1
101 GU5.3 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Base 7006-109-1
102 GX5.3 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Base 7006-73B-2
103 GY5.3 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Base 7006-73C-2
104 2G10 โ€œGoโ€ Gauge for Caps on Finished Lamps 7006-118-1
105 GX10q โ€œGoโ€ Gauge for Caps on Finished Lamps 7006-84-2
106 GX10q โ€œNot Goโ€ Gauge A for Caps on Finished Lamps 7006-84A-1
107 GX10q โ€œNot Goโ€ Gauge B for Caps on Finished Lamps 7006-84B-1
108 GX10q โ€œGoโ€ Gauges for Keys on Finished Lamps 7006-84E-1
109 GX10q โ€œNot Goโ€ Gauges for Caps on Finished Lamps 7006-84F-1
110 GY10q โ€œGoโ€ Gauge for Caps on Finished Lamps 7006-85-2
111 GY10q โ€œNot Goโ€ Gauge A for Caps on Finished Lamps 7006-85A-1
112 GY10q โ€œGoโ€ Gauges for Keys on Finished Lamps 7006-85D-1
113 GY10q โ€œNot Goโ€ Gauges for Caps on Finished Lamps 7006-85E-1
114 G10q, GY10q โ€œGoโ€ Gauge 7006-79-2
115 G12 โ€œGoโ€ Gauge for Caps on Finished Lamps 7006-80-1
116 PG12, PGX12 Lamp Cap โ€œGoโ€ Gauge 7006-81-3
117 Fc2 Lamp Cap โ€œGoโ€ Gauge 7006-114-1
118 GR8 โ€œGoโ€ Gauge for Caps on Finished Lamps 7006-68-2
119 GR8 Gauge for caps to ensure entry of maximum lampholders and to check pin-spacing and length 7006-68A-2
120 GR8, GR10q โ€œGoโ€ Gauge for checking the pins of caps on finished lamps 7006-68E-1
121 GR8, GR10q โ€œGoโ€ and โ€œNot Goโ€ Gauge for checking the pins of caps 7006-68F-1
122 2G13 Lamp Cap โ€œGoโ€ Gauge 7006-33-2
123 2G72GX7 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-102-1
124 G23 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-69-2
125 GX23 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-86-1
126 G24GX24 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-78-3
127 GX32 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-87-2
128 G4 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Lamp Bases 7006-72-1 A B
129 GU4 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Lamp Bases 7006-108-2
130 GZ4 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Lamp Bases 7006-67-1
131 G6.35 GX6.35 GY6.35 GZ6.35 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Bases 7006-61-5
132 G6.35 GX6.35 GY6.35 โ€œGoโ€ Gauge for Bi-pin Bases 7006-61A-3
133 GZ6.35 โ€œGoโ€ Gauge for Bi-pin Bases 7006-59B-1
134 GU7 โ€œGoโ€ and โ€œNot Goโ€ Gauge for Bi-pin Bases 7006-113-2
135 R17d โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-57-3
136 Fa6 โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-41-2
137 Fa8 โ€œGoโ€ Gauge 7006-40-1
138 Fa8 โ€œNot Goโ€ Gauge 7006-40A-1
139 2G11 โ€œGoโ€ Gauge 7006-82-1
140 B15 Lamp Holder โ€œGoโ€ Gauge 7006-12D-2
141 B15d Lamp Holder โ€œNot Goโ€ Gauge 7006-12C-2
142 B15d Lamp Holder Gauge for checking contact position and contact force in bayonet lampholders 7006-15B-1
143 B15d Lamp Holder Gauges for the slots in the lampholders 7006-13-5
144 E17 Lamp Holder โ€œGoโ€ Gauge 7006-25H-1
145 E17 Lamp Holder โ€œNot Goโ€ Gauge 7006-26C-1
146 E17 Lamp Holder Gauges for testing contact-making in lampholders 7006-26E-1
147 E26 โ€œGoโ€ Gauge 7006-25B-2
148 E26 & E26d โ€œNot Goโ€ Gauge 7006-26A-2
149 E26d Plug gauge for testing protection against accidental contact in E26d lampholder 7006-29J-1
150 G6.35 Lamp Holder Min. Retention Gauge 7006-61C-4
151 G6.35 Lamp Holder โ€œGoโ€ Gauge 7006-61B-4
152 G12 Lamp Holder โ€œGoโ€ Gauge A 7006-80A-2
153 G12 Lamp Holder โ€œGoโ€ Gauge B 7006-80B-2
154 G12 Lamp Holder โ€œGoโ€ Gauge C 7006-80C-2
155 G12 Lamp Holder โ€œGoโ€ Gauge D 7006-80D-3
156 G12 Lamp Holder โ€œGoโ€ Gauge E 7006-80E-3
157 R7S Gauges for testing contact-making 7006-62-4
158 G5.3 Lamp Holder โ€œGoโ€ Gauge 7006-73A-1
159 GX53 Lamp Holder โ€œGoโ€ Gauge A 7006-142A-1
160 GX53 Lamp Holder โ€œGoโ€ Gauge B 7006-142B-1
161 GX53 Lamp Holder โ€œGoโ€ Gauge C 7006-142C-1
162 GX53 Lamp Holder โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-142G-1
163 GX53 Lamp Holder โ€œNot Goโ€ Gauge 7006-142H-1
164 R7S Lamp Holder โ€œGoโ€ Gauge 7006-62-1
165 GX5 Lamp Holder โ€œNot Goโ€ Gauge 7006-142J-1
166 E5 Lamp Holder โ€œGoโ€ Gauge 7006-25F-1
167 E5 Lamp Holder โ€œNot Goโ€ Gauge 7006-25G-1
168 E10 Lamp Holder โ€œGoโ€ Gauge 7006-25-7
169 EP10 Lamp Holder โ€œGoโ€ Gauge 7006-37A-1
170 E10 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
171 EY10 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
172 EP10 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
173 EY10 Lamp Holder โ€œGoโ€ Gauge 7006-7A-1
174 E11 Lamp Holder Gauges A for testing contact-making 7006-6A-1
175 E11 Lamp Holder Gauges B for testing contact-making 7006-6B-1
176 E12 Lamp Holder โ€œGoโ€ Gauge 7006-25C-1
177 E12 Lamp Holder โ€œNot Goโ€ Gauge 7006-26B-1
178 E12 Lamp Holder Contact-making Gauge 7006-32A-1
179 E17 Lamp Holder โ€œGoโ€ Gauge 7006-25H-1
180 E17 Lamp Holder โ€œNot Goโ€ Gauge 7006-26C-1
181 E17 Lamp Holder Gauges for testing contact-making 7006-26E-1
182 E26 Lamp Holder โ€œGoโ€ Gauge 7006-25B-2
183 E26 Lamp Holder โ€œNot Goโ€ Gauge 7006-26A-2
184 E26d Lamp Holder โ€œNot Goโ€ Gauge 7006-26A-2
185 E26 Lamp Holder Gauges for testing contact-making 7006-25J-1
186 E26d Lamp Holder โ€œGoโ€ Gauge 7006-29K-1
187 E26d Lamp Holder Gauges for testing contact-making 7006-29G-3
188 E26d Lamp Holder Gauge for checking the radial position of the intermediate contact of lampholder 7006-29E-1
189 E26d Lamp Holder Gauge for testing the relative positions of the contacts in lampholder 7006-29F-1
190 E26d Lamp Holder Gauge for testing contact-making in metal-shell paper-lined lampholders 7006-29H-3
191 E26d Lamp Holder Plug gauge for testing protection against accidental contact 7006-29J-1
192 E26d Lamp Holder Gauge for testing unacceptable contact-making in lampholders 7006-29M-1
193 E39 Lamp Holder โ€œGoโ€ Gauge 7006-24E-1
194 E39 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
195 E39 Lamp Holder Gauges for testing contact-making 7006-24D-1
196 E39 Lamp Holder Gauge for testing maximum insertion torque in lampholders with shell-grip features 7006-24F-1
197 E39 Lamp Holder Gauge for testing minimum insertion torque in lampholders with shell-grip features 7006-24G-1
198 E40 Lamp Holder โ€œGoโ€ Gauge 7006-25-7
199 E40 Lamp Holder โ€œNot Goโ€ Gauge 7006-26-4
200 E40 Lamp Holder Gauges for testing contact-making 7006-23-3
201 E40 Lamp Holder Plug gauge for lampholders for testing protection against accidental contact 7006-24-3
202 Lamp Holder Accessories Torque Test Cap IEC 60238 Figure5
203 GX53 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge 7006-142-1
204 GX53 Lamp Cap โ€œNot Goโ€ Gauge 7006-142D-1
205 GX53 Lamp Cap โ€œGoโ€ and โ€œNot Goโ€ Gauge for checking keyways in caps 7006-142E-1
206 GX53 Lamp Cap โ€œNot Goโ€ Gauge for checking keyways in caps 7006-142F-1

E27 Lamp Cap Gauge Detail Display

E27 Lamp Cap Gauge FAQs

What is the E27 Lamp Cap Gauge 7006-51-2 and what does it test?
The E27 Lamp Cap Gauge 7006-51-2 is a precision Go/No-Go gauge designed to verify protection against accidental contact for E27/51ร—39 caps on finished lamps in accordance with IEC 60061-3. It ensures that live electrical parts remain inaccessible during normal handling or installation, preventing electric shock hazards. (See Testing Principle section above for the exact test method.)
How do you correctly use the E27 Lamp Cap Gauge 7006-51-2?
Simply push the finished E27 lamp fully into the gauge until it stops naturally. The test passes if surface W of the lamp cap does not protrude beyond surface V of the gauge. This quick handheld operation requires no additional tools and is ideal for production-line or laboratory verification of E27 Lamp Cap Gauge 7006-51-2 IEC 60061-3 compliance. (Refer to Product Features and carousel image #3 for a visual demonstration of the insertion test.)
What do surfaces V and W represent in the E27 Lamp Cap Gauge test?
Surface V is the critical reference plane on the gauge, while surface W is the corresponding surface on the lamp cap. According to IEC 60061-3, the test passes if surface W remains flush with or below surface V when the lamp is fully inserted. This confirms the cap geometry provides adequate protection against accidental contact with live parts.
Is the E27 Lamp Cap Gauge 7006-51-2 only suitable for finished lamps?
Yes. The 7006-51-2 gauge is specifically engineered for caps already mounted on finished lamps (E27/51ร—39 series). It is not intended for bare caps or lampholders. This makes it the standard tool used by lighting manufacturers and certification laboratories for final product safety validation under IEC 60061-3.
What is the difference between the 7006-51-2 and 7006-51A-2 gauges?
The 7006-51-2 checks protection against accidental contact on E27/51ร—39 caps on finished lamps, while the 7006-51A-2 is designed for standard E27 caps and focuses on protection during lamp insertion. Both follow IEC 60061-3 but serve slightly different dimensional and application requirements. Most manufacturers use the 7006-51-2 specifically for E27/51ร—39 variants on completed lamps.
How often should the E27 Lamp Cap Gauge 7006-51-2 be calibrated or verified?
For optimal accuracy, perform periodic dimensional verification every 6โ€“12 months or after 5,000โ€“10,000 test cycles, depending on usage volume. Each gauge ships with a factory traceable calibration certificate; third-party ISO 17025 accreditation is available upon request. (See Metrological Integrity & Validation section for detailed recommendations.)
Why is protection against accidental contact testing important for E27 lamps?
It is a mandatory safety requirement under IEC 60061-3 to ensure live parts inside the lamp cap remain inaccessible during normal use, installation, or maintenance. Passing the E27 Lamp Cap Gauge 7006-51-2 test significantly reduces electric shock risk, helps manufacturers achieve global market access, and prevents costly product recalls.
Can the E27 Lamp Cap Gauge 7006-51-2 be used on the production line?
Absolutely. Its compact, ergonomic handheld design and clear visual pass/fail reference surfaces (V and W) make it perfect for fast, high-volume in-line inspection. Operators require minimal training, and the hardened steel construction (HRC 58โ€“60) ensures reliable performance in demanding manufacturing environments. (See carousel image #6 for production-line usage example.)
What material is the E27 Lamp Cap Gauge made of and how durable is it?
The gauge is precision-machined from premium hardened steel with a hardness of HRC 58โ€“60, providing exceptional wear resistance and long-term dimensional stability. With proper care and periodic cleaning, it maintains IEC 60061-3 accuracy for thousands of test cycles.
Does the E27 Lamp Cap Gauge 7006-51-2 come with a calibration certificate?
Yes. Every unit is delivered with a complimentary factory traceable calibration certificate. We also offer optional third-party ISO 17025 accredited calibration reports for laboratories requiring formal traceability.

Related Products

Related News

KINGPO ISO 5356-1 Gauge delivers precise, repeatable testing for medical connectors, ensuring safety, compliance, and ease of use in device quality assurance.

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

In the realm of electrical safety, where materials must endure potential fire risks, the Kingpo KP-FT01 Glow Wire Tester emerges […]

Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]

ISO 5356-1:2015 is the internationally recognized standard titled Anaesthetic and respiratory equipment โ€” Conical connectors โ€” Part 1: Cones and […]

IEC 60309 connector variants differ by configuration, current rating, and environment. Choosing the right type ensures safety, reliability, and compliance.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Enhancing Electrical Safety with IEC 60309 Compliance Gauges 18 I see electrical safety as a top priority in every industrial […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.