EN 60360 Figure 3 E14/20 Lamp Cap | IEC 60360 Lamp Cap Temperature Rise Test Sleeve
The EN 60360 Figure 3 E14/20 Lamp Cap supports precise lamp cap temperature rise testing, offering stable nickel construction for lighting manufacturers and testing laboratories.
- Standard Compliance: Designed according to EN 60360 / IEC 60360 Figure 3 for E14/20 lamp cap temperature rise testing
- Application: Used for auxiliary temperature rise testing of tungsten filament lamps, discharge lamps, and related lighting products
- Lamp Cap Type: Suitable for E14/20 lamp cap temperature rise test applications
- Material: Nickel 99% min. for stable thermal performance and reliable test repeatability
- Thickness: 0.5 mm ยฑ 0.02 mm, supporting consistent test sleeve geometry
- Hardness: Vickers hardness 135 ยฑ 15 for mechanical stability during repeated testing
- Test Use: Applied with a draught-proof enclosure and temperature measurement system
- Certificate: Calibration certificate available upon request
- MOQ: 1 set
- Delivery Time: 25 working days
EN 60360 Figure 3 E14/20 Lamp Cap Description
EN 60360 Figure 3 – E14/20 Lamp Caps
The EN 60360 Figure 3 E14/20 Lamp Cap is a precision temperature rise test sleeve designed for lamps fitted with E14/20 caps. It supports standardized lamp cap temperature rise measurement in accordance with IEC 60360.Made from Nickel 99% min., this test sleeve provides stable thermal performance and reliable repeatability for lighting manufacturers, testing laboratories, and certification bodies.
Technical Parameters
| Item | Specification | Remark / Notes |
|---|---|---|
| Applicable Standard | EN 60360 / IEC 60360 | Lamp cap temperature rise measurement |
| Figure Reference | Figure 3 | E14/20 test sleeve |
| Product Type | Lamp cap temperature rise test sleeve | Auxiliary test accessory |
| Lamp Cap Type | E14/20 | Edison screw cap application |
| Material | Nickel 99% min. | Stable thermal performance |
| Thickness | 0.5 mm ยฑ 0.02 mm | Standard test sleeve thickness |
| Vickers Hardness | 135 ยฑ 15 | Mechanical durability |
| Test Environment | Draught-proof enclosure | Reduces airflow interference |
| Application | Lamp cap temperature rise test | For lighting safety evaluation |
| Certificate | Available upon request | Supports laboratory traceability |

Professional Construction & Technical Precision
The E14/20 Lamp Cap Temperature Rise Test Sleeve is precision-manufactured from high-purity nickel to ensure stable thermal conductivity and repeatable measurement conditions. Its controlled thickness and hardness help maintain consistent contact and mechanical stability during repeated laboratory testing.
The sleeve is designed for use with lamp cap temperature rise test systems. It helps laboratories reproduce the required test arrangement and obtain reliable temperature data for product safety assessment.
Testing Principle
The purpose of lamp cap temperature rise testing is to verify whether the lamp cap temperature remains within acceptable safety limits during operation. Excessive temperature rise may affect insulation performance, lamp holder reliability, and long-term product safety.
During testing, the lamp is operated under specified conditions inside a draught-proof enclosure. The E14/20 lamp cap test sleeve is used as part of the measurement arrangement to support stable and repeatable temperature rise evaluation.
Common Error Mitigation
To achieve accurate and repeatable test results, the following practices are recommended:
- Confirm that the sleeve corresponds to EN 60360 / IEC 60360 Figure 3 before testing.
- Ensure the test is conducted inside a suitable draught-proof enclosure.
- Check the sleeve surface before use and avoid damaged or deformed components.
- Verify correct thermocouple or temperature sensor positioning.
- Maintain stable test voltage, ambient temperature, and test duration.
- Record all key parameters, including lamp type, voltage, test time, ambient temperature, and measured temperature rise.

Primary Use Cases & Business Value
The EN 60360 Figure 3 E14/20 Lamp Cap provides a reliable solution for standardized lamp cap temperature rise testing. It helps manufacturers identify potential overheating risks during product development and supports laboratories in performing repeatable compliance testing.
By using a dedicated standard-based test sleeve instead of a general fixture, users can improve test consistency, reduce measurement deviation, and strengthen the credibility of test reports.
Industrial Applications & Lab Scenarios
- Lighting Manufacturers โ Lamp cap thermal performance verification during product development
- Third-Party Test Laboratories โ IEC / EN temperature rise compliance testing
- Certification Bodies โ Product safety evaluation and type approval support
- Quality Control Departments โ Routine inspection of lamp cap heating performance
- R&D Laboratories โ Thermal comparison of lamp structures and cap designs
Strategic Procurement Advantages & Global Support
- Designed for EN 60360 / IEC 60360 Figure 3 testing
- Suitable for E14/20 lamp cap temperature rise measurement
- Nickel 99% min. material for stable and repeatable test performance
- Controlled thickness and hardness for reliable laboratory use
- Compact structure, easy to integrate with existing lamp temperature rise test systems
- Calibration certificate support available for traceability requirements
- Suitable for lighting manufacturers, inspection agencies, and certification laboratories
Compliance & Regulatory Assurance
The EN 60360 Figure 3 E14/20 Lamp Cap is manufactured for lamp cap temperature rise testing according to EN / IEC 60360 requirements. It supports standardized test conditions for evaluating the thermal safety of lamps fitted with E14/20 caps.
- Factory Inspection: Each sleeve should be checked for dimensional accuracy, surface condition, and material consistency before delivery.
- Calibration Support: Calibration certificate can be supplied upon request for laboratory traceability.
- Routine Verification: Regular inspection is recommended to confirm that the sleeve remains free from deformation, surface damage, or oxidation.
Technical Inquiry & Expert Support
Contact our engineering team for technical drawings, calibration certificate requirements, or complete lamp cap temperature rise test solutions. Related IEC 60360 test sleeves for other lamp cap types can also be supplied according to laboratory requirements.
The Core Value We Deliver
- Accurate support for IEC 60360 lamp cap temperature rise testing
- Standard-based E14/20 test sleeve according to Figure 3
- Nickel construction for stable thermal and mechanical performance
- Suitable for professional lighting safety laboratories
- Reliable calibration, documentation, and technical support available
Detail Display
EN 60360 Figure 3 E14/20 Lamp Cap FAQs
Related Products
Related News
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
ISO 5356-1:2015 is the internationally recognized standard titled Anaesthetic and respiratory equipment โ Conical connectors โ Part 1: Cones and […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]
Enhancing Electrical Safety with IEC 60309 Compliance Gauges 18 I see electrical safety as a top priority in every industrial […]