Side view of ISO 80369-7 Female Ring Gauge for checking male Luer connectors
Working end detail of ISO 80369-7 Female Ring Gauge for Luer taper verification
ISO 80369-7 Female Ring Gauge angled view for male Luer connector verification
Opposite angle view of ISO 80369-7 Female Ring Gauge for male Luer connector inspection
Side view of ISO 80369-7 Female Ring Gauge for checking male Luer connectors
Working end detail of ISO 80369-7 Female Ring Gauge for Luer taper verification
ISO 80369-7 Female Ring Gauge angled view for male Luer connector verification
Opposite angle view of ISO 80369-7 Female Ring Gauge for male Luer connector inspection

ISO 80369-7 Female Ring Gauge for Male Luer Connector Verification

The ISO 80369-7 Female Ring Gauge is a precision dimensional gauge used for checking male Luer connectors in intravascular and hypodermic medical device applications. It provides a controlled female ring interface to help verify whether the male Luer connector sample matches the required Luer taper and mating condition according to ISO 80369-7 dimensional requirements.

  • Applicable Standard: ISO 80369-7 dimensional requirements for Luer connectors
  • Product Type: Female Ring Gauge / Luer Dimensional Gauge
  • Test Object: Male Luer connectors
  • Main Purpose: Dimensional and fit verification of the male Luer connector interface
  • Typical Check: Luer taper fit, insertion condition and mating geometry
  • Material / Hardness: Hardened steel configuration; HRC58–62 can be stated only if confirmed by the supplied product specification
  • Important Note: This is a dimensional / fit verification gauge, not an ISO 80369-20 leakage tester or Annex C reference connector
  • Supply Option: Individual female ring gauge or part of an ISO 80369-7 Luer gauge set

Product Overview

ISO 80369-7 Female Ring Gauge

The ISO 80369-7 Female Ring Gauge is used to verify the external mating geometry of male Luer connectors. Instead of applying leakage pressure, axial load or stress cracking conditions, this gauge helps the user check whether the male Luer connector fits correctly with a controlled female gauge interface.

This product should not be confused with the ISO 80369-7 Figure C.1, C.3 or C.5 female reference connectors. Those Annex C reference connectors are used in specific performance test configurations, while the Female Ring Gauge is mainly used for dimensional and fit verification based on Luer connector geometry.

For laboratories, medical device manufacturers and QC teams, this gauge is useful before formal functional testing. It helps identify whether a male Luer connector sample has an obvious dimensional or mating issue before using ISO 80369-20 leakage, air leakage or axial load test equipment.


Standard Background and Correct Positioning

ISO 80369-7 includes dimensional requirements for Luer connectors and provides Luer connector dimension figures and tables in Annex B. The Female Ring Gauge is best understood as a practical inspection gauge based on those Luer connector dimensional requirements.

It is different from ISO 80369-7 Annex C reference connectors:

Item Correct Understanding
Female Ring Gauge Dimensional / fit verification gauge for male Luer connectors
Annex C Reference Connectors Reference connectors used in specified ISO 80369-7 performance test configurations
ISO 80369-20 Test Equipment Test apparatus used for leakage, air leakage, axial load or related performance tests

This distinction is important for both purchasing and page SEO. Customers searching for a Female Ring Gauge usually need a dimensional inspection tool, not a complete test system.


What This Female Ring Gauge Checks

The Female Ring Gauge is used to check male Luer connector samples. The working end of the gauge provides a female ring / internal interface. During inspection, the male Luer connector is inserted into or mated with the gauge to evaluate whether the external Luer taper and mating condition are suitable.

Typical verification purposes include:

  • Checking the external Luer taper of a male Luer connector
  • Confirming basic mating fit before further functional testing
  • Supporting incoming inspection of male Luer connector components
  • Helping R&D teams compare connector samples during design verification
  • Supporting factory QC checks for production batches

This gauge does not replace a complete leakage tester, axial load tester or resistance-to-overriding test setup.


How It Is Used

Typical Use Procedure

  1. Confirm that the sample is a male Luer connector.
  2. Clean the sample and the Female Ring Gauge working interface before inspection.
  3. Insert or mate the male Luer connector with the female ring gauge interface according to the internal inspection procedure.
  4. Observe whether the connector fits the gauge as expected.
  5. Record the inspection result according to the laboratory or factory QC requirement.
  6. After inspection, clean the gauge and store it in a protective case.

Important Use Note

The Female Ring Gauge should be used only for dimensional or fit verification. If the customer needs leakage, sub-atmospheric pressure air leakage, axial load separation, unscrewing separation, stress cracking or resistance-to-overriding testing, the appropriate ISO 80369-20 test apparatus and ISO 80369-7 reference connector should be selected according to the test method.


Technical Features

  • Designed for ISO 80369-7 related male Luer connector dimensional and fit verification
  • Female ring gauge interface for checking male Luer connector mating geometry
  • Suitable for male Luer connector incoming inspection, R&D checking and factory QC
  • Precision-machined working interface for repeatable fit verification
  • Hardened steel construction can be supplied according to product specification
  • HRC58–62 hardness may be stated when confirmed by KINGPO’s product drawing or inspection document
  • Compact hand-held structure for convenient laboratory or production inspection
  • Available individually or as part of a Luer connector gauge set
  • Product datasheet, material information, dimensional confirmation or hardness confirmation can be provided where applicable

Operation and Handling Notes

The Female Ring Gauge is a precision inspection tool and should be handled carefully.

  • Confirm the sample is a male Luer connector before use.
  • Do not use this gauge as a leakage tester or force test fixture.
  • Keep the ring gauge interface clean and free from scratches.
  • Do not force an obviously incompatible or damaged connector into the gauge.
  • Avoid impact, corrosion or contamination during storage and use.
  • Store the gauge in a protective case after inspection.
  • Confirm documentation requirements before order placement if the gauge will be used in a regulated laboratory or internal QC system.

Who Needs This Gauge

Customer Type Typical Need
Male Luer connector manufacturers Routine dimensional and fit verification of male Luer connector samples
Syringe and needle manufacturers Incoming inspection and production QC of male Luer connector parts
IV cannula and infusion accessory manufacturers Checking male Luer connector mating condition before assembly or testing
Medical device R&D teams Comparing connector prototypes during design verification
Third-party testing laboratories Pre-checking customer samples before formal ISO 80369 testing
Factory QC laboratories Batch inspection and internal quality control
Certification support teams Preparing dimensional evidence before performance testing

Compliance & Regulatory Assurance

This ISO 80369-7 Female Ring Gauge is manufactured for dimensional and fit verification of male Luer connectors according to ISO 80369-7 related Luer connector requirements. It helps customers check the mating condition of male Luer connector samples before further functional testing.

KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.

Product Datasheet

ISO 80369-7 Female Ring Gauge

Download the PDF datasheet for product overview, dimensional verification purpose, use notes and technical inquiry support.
Download Datasheet

Technical Inquiry & Expert Support

The ISO 80369-7 Female Ring Gauge is a standard dimensional / fit verification gauge. To help KINGPO confirm the correct item and supporting documentation, please provide:

  • Required product: ISO 80369-7 Female Ring Gauge
  • Quantity required
  • Your sample type, especially male Luer slip or male Luer lock connector
  • Whether the gauge is required individually or as part of a Luer gauge set
  • Intended use, such as R&D checking, incoming inspection or production QC
  • Any material, hardness or dimensional confirmation requirement
  • Whether related ISO 80369-20 performance test equipment is also required

KINGPO can help review your sample type and inspection purpose before quotation to confirm whether the Female Ring Gauge or another ISO 80369-7 gauge is more suitable.

Difference from Related ISO 80369-7 Products

Related Product Difference
ISO 80369-7 Female Ring Gauge Dimensional / fit verification gauge for male Luer connectors
ISO 80369-7 Male Plug Gauge Dimensional / fit verification gauge for female Luer connectors
ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector Annex C reference connector used in specific male Luer connector test configurations
ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector Annex C female reference connector for male Luer connector performance test configurations
ISO 80369-7 Luer Gauge Set Complete set option for laboratories needing multiple Luer gauges and reference connectors
ISO 80369-20 Test Equipment Test apparatus for leakage, air leakage, axial load or other performance tests

This distinction helps customers avoid selecting an Annex C reference connector when they only need a dimensional / fit verification gauge.

ISO 80369-7 Female Ring Gauge

FAQ

What is the ISO 80369-7 Female Ring Gauge used for?
It is used for dimensional and fit verification of male Luer connectors. The gauge provides a controlled female ring interface to help check whether the male Luer connector sample has the expected mating geometry according to ISO 80369-7 related dimensional requirements.
Is the Female Ring Gauge the same as an Annex C reference connector?
No. The Female Ring Gauge is mainly a dimensional / fit verification gauge. ISO 80369-7 Annex C reference connectors, such as Figure C.1, C.3 and C.5, are used in specific performance test configurations and should not be treated as the same product.
What sample is checked by the Female Ring Gauge?
The Female Ring Gauge is used to check male Luer connector samples. If the sample is a female Luer connector, the ISO 80369-7 Male Plug Gauge is usually the more relevant dimensional / fit verification gauge.
Does this gauge perform leakage testing?
No. The Female Ring Gauge does not apply pressure or measure leakage. Leakage or air leakage testing requires the appropriate ISO 80369-20 test equipment and the correct reference connector according to the selected test method.
Why does the gauge look like a hand tool?
The handle is used for holding, inserting and protecting the precision working end. The actual gauge function is provided by the female ring / internal gauge interface at the front end, not by the handle.
Is HRC58–62 required by ISO 80369-7?
HRC58–62 should be treated as a KINGPO product material / hardness specification if confirmed by the product drawing or inspection document. It should not be presented as a general ISO 80369-7 requirement unless the applicable document specifically requires it.
Can it be supplied with documentation?
Yes. KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. If your laboratory has specific documentation requirements, please confirm them before order placement.
Can this gauge be supplied as part of a complete ISO 80369-7 gauge set?
Yes. The Female Ring Gauge can be supplied individually or as part of a broader ISO 80369-7 Luer gauge set, depending on the customer’s inspection and testing scope.

Related Products

Related News

KingPo supplied ISO 80369-7 Luer Gauges to Angiosistemy LLC in Russia. The gauges are used for laboratory testing of medical […]

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.

ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]

A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.
ISO 80369 test equipment checks medical connectors for compliance, preventing misconnections and ensuring patient safety in healthcare environments.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Scroll to Top