Flammability Test for Cables – IEC 60332 Vertical Flame Propagation Tester with IEC60695-11-2 Burner for Single Cable Flame Propagation Assessment
Flammability Test for Cables – Brass Burner Φ7 ± 0.05 mm per IEC60695-11-2 for Precise IEC 60332 Vertical Flame Testing
Flammability Test for Cables – Flame Calibration with 1000W Copper Head and K-Type Thermocouple for 45 ± 5 s Rise Time
Flammability Test for Cables – 1 m³ Combustion Chamber with Metallic Screen for Safe Single Cable Flame Propagation Testing
Flammability Test for Cables – IEC 60332 Vertical Flame Propagation Tester with IEC60695-11-2 Burner for Single Cable Flame Propagation Assessment
Flammability Test for Cables – Brass Burner Φ7 ± 0.05 mm per IEC60695-11-2 for Precise IEC 60332 Vertical Flame Testing
Flammability Test for Cables – Flame Calibration with 1000W Copper Head and K-Type Thermocouple for 45 ± 5 s Rise Time
Flammability Test for Cables – 1 m³ Combustion Chamber with Metallic Screen for Safe Single Cable Flame Propagation Testing

Flammability Test for Cables – IEC 60332 Vertical Flame Propagation Tester

Flammability Test for Cables evaluates vertical flame propagation on single insulated cables per IEC 60332-1 series using calibrated burner and controlled chamber for fire safety assessment.

  • Standard Compliance: IEC60332-1-1/1-2/1-3:2004 – flammability test for cables with vertical flame propagation
  • Burner Design: Brass IEC60695-11-2 Annex A/B, opening Φ7 ± 0.05 mm – propane-air mixture for stable flame
  • Flame Calibration: 45 ± 5 s rise from 100 ± 5°C to 700 ± 3°C with 1000W copper head
  • Sample Setup: Length 600 ± 25 mm, bottom distance 50 mm, supports at 550 mm interval
  • MOQ: 1
  • Price: To be quoted

Flammability Test for Cables Description

Flammability Test for Cables – IEC 60332 Vertical Flame Propagation Performance Assessment

The Flammability Test for Cables represents a high-precision fire performance evaluation system engineered by KingPo to rigorously determine the vertical flame propagation characteristics of single insulated cables and optical cables. Utilizing a standardized blast burner compliant with IEC60695-11-2 Annex A and B, the apparatus applies a controlled pre-mixed propane-air flame to the base of a vertically suspended cable specimen. It precisely quantifies flame spread distance, residual burning duration, and the occurrence of flaming droplets or particles in accordance with:

  • IEC 60332-1-1:2004 (test apparatus specification)
  • IEC 60332-1-2:2004 (pre-mixed flame test procedure)
  • IEC 60332-1-3:2004 (assessment of flaming droplets/particles)
  • IEC 60332-2-2 (alternative flame application methods)

This flammability test for cables is indispensable for manufacturers, certification bodies, and quality assurance teams seeking to validate insulation material integrity under vertical flame exposure—critical for power distribution cables, telecommunication lines, building wiring, and appliance interconnects where fire propagation resistance directly impacts life safety and regulatory compliance.

KingPo Factory Advantages

As an ISO9001 and CE-certified manufacturer with established global export channels, KingPo has successfully delivered more than 140 units of this flammability test for cables equipment to leading cable producers and accredited testing laboratories across China, Europe, and Southeast Asia since 2020. Every unit is supplied with traceable CNAS calibration certificates. The system includes lifetime free software upgrades and a guaranteed 48-hour.

Professional Construction & Technical Precision

The equipment incorporates advanced engineering features to deliver repeatable, standards-compliant results:

  • Burner Assembly — High-quality brass construction per IEC60695-11-2, with burner opening diameter Φ7 ± 0.05 mm and dual high-accuracy flowmeters ensuring propane flow of 650 ± 30 mL/min and air flow of 10 ± 0.5 L/min
  • Flame Calibration System — 1000 W copper block (Φ9 mm ± 0.01 mm, pre-drilling mass 10 ± 0.05 g) paired with Omega-armored K-type thermocouple, achieving temperature rise from 100 ± 5°C to 700 ± 3°C in exactly 45 ± 5 s
  • Ignition & Control — Fully automatic intake ignition with maximum delay of 0.1 s, combined with electrical push-button interface and 9999 × 0.1 s precision timing
  • Specimen Mounting — Vertical fixture supporting cable lengths of 600 ± 25 mm, lower edge positioned 50 mm above burner, with rigid horizontal supports spaced at 550 mm intervals
  • Combustion Enclosure — 1 m³ volume chamber equipped with protective metallic screen (H1200 × W300 × D450 mm), providing stable, enclosed conditions for safe and observable testing
  • Angle Adjustability — 0–90° continuous adjustment to accommodate diverse test configuratio

These design elements guarantee high reproducibility and traceability in every single cable flame propagation test.

Flammability Test for Cables – IEC 60332 Vertical Flame Propagation Tester with IEC60695-11-2 Burner for Single Cable Flame Propagation Assessment

Primary Use Cases & Business Value

This flammability test for cables delivers tangible benefits across multiple operational stages:

  • Material & Design Validation — Quantifies insulation resistance to vertical flame spread in power, control, and data cables
  • Regulatory Certification Support — Produces auditable test data required for IEC 60332-1 series compliance certification
  • In-Process Quality Assurance — Enables rapid batch verification to detect and eliminate propagation-prone insulation formulations
  • Risk Mitigation & Product Improvement — Provides actionable insights to enhance cable fire performance and reduce potential fire spread in end-use environments

Early identification of non-compliant behaviour accelerates design iteration, shortens time-to-market, and strengthens overall product safety credentials.

Compliance & Regulatory Assurance

The flammability test for cables equipment fully complies with IEC 60332-1-1:2004, IEC 60332-1-2:2004, IEC 60332-1-3:2004, IEC 60332-2-2, and GB/T 18380 series. Vertical flame propagation resistance is a key global safety requirement for cables.

The NIST (National Institute of Standards and Technology) provides extensive research on cable fire dynamics and material performance. The NFPA (National Fire Protection Association) regularly updates electrical safety codes (e.g., NFPA 70) to address flame risks in wiring. For detailed engineering analysis, technical papers on cable flame propagation and fire modeling are available on IEEE Xplore. Regular calibration ensures traceability and acceptance by certification bodies.

Procurement Benefits

  • Featuring intuitive electrical controls, automatic ignition sequencing, and a robust enclosed chamber, the flammability test for cables minimizes setup time and operator dependency while maximizing test repeatability. Each unit is accompanied by detailed technical documentation, CNAS-accredited calibration certificates, and lifetime software update entitlement.
  • Investing in this equipment elevates your cable fire safety validation capability, reduces non-conformance risks, and supports faster achievement of international market access. Contact us today for a tailored quotation and technical consultation—we guarantee a response within 24 hours with comprehensive specifications and customized pricing.
Flammability Test for Cables.pdf

Flammability Test for Cables Technical

Parameter Specification
Model Number Flammability Test for Cables
Burner Opening Φ7 ± 0.05 mm (brass, IEC60695-11-2 Annex A/B)
Gas Flow Propane 650 ± 30 mL/min + Air 10 ± 0.5 L/min
Flame Rise Time 45 ± 5 s (100 ± 5°C to 700 ± 3°C)
Burning Time 9999 × 0.1 s
Test Angle 0–90° adjustable
Sample Length 600 ± 25 mm, bottom distance 50 mm
Support Distance 550 mm
Combustion Chamber 1 m³

Technical Inquiry for Flammability Test for Cables

We provide high-precision flammability test for cables equipment direct from KingPo factory, ensuring reliable IEC 60332 vertical flame propagation testing.

The Core Value We Deliver to You

  • Precise Flame – IEC60695-11-2 burner with calibrated 45 s rise time
  • Safe Operation – 1 m³ chamber and automatic ignition delay ≤0.1 s
  • Factory Advantages – MOQ 1 unit, 15-day delivery, 1-year warranty, ISO9001 & CE
  • Complete Testing Support – Pair with our flame test series for full checks
  • Faster Certification – Reduce flame propagation risks through accurate testing

Take Action Now – Submit inquiry in 30 seconds for best price, stock status, and technical support within 24 hours!

Flammability Test for Cables Applications

Product Application Area Detailed Description

  • Power & Communication Cables – Single cable flame propagation resistance
  • Building Wiring – Insulation performance in vertical flame conditions
  • Appliance Cables – Compliance with IEC 60332-1 series standards
  • Certification Labs & QA – Flame spread and droplet testing
  • Cable Manufacturing – Batch quality control for flammability test for cables

Flammability Test for Cables Video

Flammability Test for Cables Details

Flammability Test for Cables FAQ

Does this equipment support both IEC 60332 and UL 1581 VW-1 testing?
Yes, it fully complies with IEC 60332-1 series and UL 1581 Sections 1080.1–1080.14 (VW-1 vertical flame test). It also covers UL13, UL444, UL1655 VW-1, and CSA FT-1/FT-2. The burner and procedure are compatible with both standards.
What are the pass/fail criteria for VW-1 or IEC 60332?
For VW-1: After 5 cycles (15 s flame + 15 s off), self-extinguish ≤60 s, Kraft paper flag burn ≤25%, and cotton below burner unignited. For IEC 60332-1: Flame must not exceed 540 mm from burner, and droplets must not ignite filter paper.
How do I calibrate the flame height and temperature?
Adjust flame to inner 55±5 mm / outer 180±10 mm using dual flowmeters. Calibrate rise time (100±5°C to 700±3°C in 45±5 s) with the included 1000 W copper block and K-type thermocouple. Do this every 3–6 months or after gas change.
What’s the exhaust setup like for the 4.32 m³ chamber?
Top exhaust opens automatically after test to vent gases outdoors; it stays closed during testing. Install with external ducting. The chamber uses aluminum frame + electrostatic spray for corrosion resistance.
Can it do vertical and horizontal tests (FT1/FT2, VW-1)?
Yes. It includes stainless steel supports for vertical (VW-1) and horizontal (FT1/FT2). Switch fixtures, adjust burner angle (90° horizontal / 20° vertical), and select mode. Vertical support aligns with observation window for easy viewing.
Is the test fully automatic or do I need to intervene a lot?
Ignition, flame cycles (on/off timing, repetitions), and duration are fully automatic. You just place the sample, start via button, and observe/record. Minor burner adjustments can be made through sealed glove ports.
Is the burner IEC or UL specific? Are parameters the same?
It meets both IEC60695-11-2 and UL 1581 (ASTM D 5025): vertical 500 W, horizontal 225 W, nozzle Ø0.90±0.03 mm, length 1.60±0.05 mm, nozzle-to-air 102 mm. Fully interchangeable.
How safe is the equipment? How is smoke and gas handled?
Sealed chamber with tempered glass window and glove ports prevents exposure. Post-test automatic exhaust vents gases outdoors. Corrosion-resistant materials and sealed design ensure lab safety.
How often should I calibrate, and is it costly?
Calibrate annually or after ~500 tests (burner, flowmeters, thermocouple, copper block). We provide CNAS-calibrated service with 48-hour on-site response during warranty. Cost is reasonable and often bundled in support.
Is it suitable for lab certification or production line testing?
Perfect for certification labs, R&D, and production sampling. MOQ 1 unit, delivery ~15 days, 1-year warranty + lifetime software updates, 48-hour support. We can customize for higher throughput if needed.

Related Products

Related News

Abstract The IEC 60332-1-2 Cable Flammability Test serves as a critical benchmark for evaluating the fire safety integrity of modern […]

Meet UL94 and IEC standards with the horizontal vertical flame tester. Follow step-by-step testing and compliance procedures for reliable fire safety results.
Ensure ISO 14117 compliance for AIMDs by using a Defibrillation Test Pulse Generator to meet safety standards and document reliable defibrillation immunity testing.
IP Testing Equipment simulates dust and water exposure, ensuring products resist harsh environments and avoid failures by meeting global standards.

Dongguan, China – 10 25, 2024 – In a significant advancement for food safety technology, Chao Zhang (also known as […]

For plastic insulation frames, given the high heat generated by the copper wires and iron core, if the flame retardant […]

Environmental test chamber solutions boost product reliability by simulating real-world stress, identifying weaknesses, and ensuring consistent performance.

Dynamic Compensation Implementation for High-Frequency Electrosurgical Unit Testing Using High-Frequency LCR or Network Analyzers Above MHz Shan Chao1, Qiang Xiaolong2, […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.