ISO 80369-7 Luer Gauge Set and Reference Connectors
The ISO 80369-7 Luer Gauge Set and Reference Connectors are used for Luer connector verification in intravascular and hypodermic medical device applications. KINGPO supplies ISO 80369-7 Figure C.1 to Figure C.6 reference connectors, Male Plug Gauge and Female Ring Gauge individually or as a complete set according to the customer’s sample type and test scope.
- Applicable Standard: ISO 80369-7
- Product Type: Luer reference connector set / dimensional gauge set
- Included Items: Figure C.1 to C.6 reference connectors, Male Plug Gauge and Female Ring Gauge
- Test Objects: Male and female Luer slip / Luer lock connectors
- Main Purpose: Luer connector verification, reference mating and dimensional / fit checking
- Typical Users: Medical device manufacturers, R&D laboratories, QC departments and third-party testing laboratories
- Supply Option: Individual connector, selected gauges or complete set
- Important Note: Functional tests such as liquid leakage, subatmospheric air leakage or axial load testing may require ISO 80369-20 test equipment
Product Overview
ISO 80369-7 Luer Gauge Set and Reference Connectors
The ISO 80369-7 Luer Gauge Set helps laboratories and manufacturers select the correct reference connector or dimensional gauge for Luer connector verification. It is useful when customers need to confirm whether the sample is a male Luer connector, female Luer connector, Luer slip connector or Luer lock connector.
The set covers ISO 80369-7 Figure C.1 to Figure C.6 reference connectors, as well as Male Plug Gauge and Female Ring Gauge for dimensional and fit checking. Each item can be supplied separately or combined into a set according to the customer’s test scope.
If the project requires liquid leakage, subatmospheric air leakage or axial load testing, suitable ISO 80369-20 test equipment should be selected together with the required ISO 80369-7 reference connector, dimensional gauge or fixture.
Quick Selection Guide
| Your Sample / Test Need | Recommended KINGPO Item | Typical Purpose |
|---|---|---|
| Male Luer connector | Figure C.1, Figure C.3, Figure C.5 or Female Ring Gauge | Reference mating or dimensional / fit verification for male Luer connectors |
| Female Luer connector | Figure C.2, Figure C.4, Figure C.6 or Male Plug Gauge | Reference mating or dimensional / fit verification for female Luer connectors |
| Male Luer connector dimensional check only | ISO 80369-7 Female Ring Gauge | Basic dimensional and fit verification of male Luer connectors |
| Female Luer connector dimensional check only | ISO 80369-7 Male Plug Gauge | Basic dimensional and fit verification of female Luer connectors |
| Liquid leakage, air leakage or axial load testing | ISO 80369-20 test equipment with suitable ISO 80369-7 reference connector | Functional performance testing using pressure, vacuum or force conditions |
This guide is intended for quick selection. The final item should be confirmed according to the connector type, sample geometry, test method and required standard clause.
Included ISO 80369-7 Reference Connectors and Gauges
| Item | Main Use | Test Object |
|---|---|---|
| ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector | Female Luer lock reference connector used in specific test configurations | Male Luer connectors |
| ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector | Male Luer slip reference connector used in specific test configurations | Female Luer connectors |
| ISO 80369-7 Figure C.3 Female Reference Connector | Female reference connector for male Luer lock connector testing | Male Luer lock connectors |
| ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector | Male Luer lock reference connector used in female Luer connector test configurations | Female Luer connectors |
| ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector | Female Luer slip reference connector used in male Luer connector test configurations | Male Luer connectors |
| ISO 80369-7 Figure C.6 Male Reference Connector | Reference connector for female Luer lock connector separation and overriding related tests | Female Luer lock connectors |
| ISO 80369-7 Male Plug Gauge | Dimensional and fit verification gauge | Female Luer connectors |
| ISO 80369-7 Female Ring Gauge | Dimensional and fit verification gauge | Male Luer connectors |
Which Item Do You Need: Reference Connector or Gauge?
Customers often confuse ISO 80369-7 reference connectors with plug / ring gauges. The difference is important when selecting the correct product.
| If You Need… | Choose… | Why |
|---|---|---|
| A mating connector for a specific ISO 80369-7 test setup | Figure C.1 to C.6 Reference Connector | These are used as reference mating parts in defined test configurations |
| A simple fit or dimensional check | Male Plug Gauge or Female Ring Gauge | These gauges help check whether the Luer connector fits the expected geometry |
| Leakage, air leakage or axial load testing | ISO 80369-20 Test Equipment | These tests require equipment that applies pressure, vacuum or force |
A reference connector creates the required mating interface for a test configuration. A dimensional gauge is mainly used to check whether the connector interface fits the expected Luer geometry. ISO 80369-20 equipment is required when the test involves pressure, leakage or mechanical loading conditions.
Selection Notes for Male and Female Luer Connectors
For Male Luer Connector Testing
If the sample is a male Luer connector, the required item may be a female reference connector or a Female Ring Gauge depending on the test purpose.
Typical related items include:
- ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector
- ISO 80369-7 Figure C.3 Female Reference Connector
- ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector
- ISO 80369-7 Female Ring Gauge
The Female Ring Gauge is mainly used for dimensional and fit verification of male Luer connectors. Figure C.1, C.3 and C.5 are reference connectors used in specific male Luer connector test configurations.
For Female Luer Connector Testing
If the sample is a female Luer connector, the required item may be a male reference connector or a Male Plug Gauge depending on the test purpose.
Typical related items include:
- ISO 80369-7 Figure C.2 Male Reference Luer Slip Connector
- ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector
- ISO 80369-7 Figure C.6 Male Reference Connector
- ISO 80369-7 Male Plug Gauge
The Male Plug Gauge is mainly used for dimensional and fit verification of female Luer connectors. Figure C.2, C.4 and C.6 are reference connectors used in specific female Luer connector test configurations.
Relationship Between ISO 80369-7 and ISO 80369-20
ISO 80369-7 is related to Luer connectors used in intravascular and hypodermic applications. It covers Luer connector requirements and related reference connector configurations. ISO 80369-20 provides common test methods for small-bore connector performance testing, including leakage, air leakage and axial load related methods.
In practical laboratory use, ISO 80369-7 reference connectors or dimensional gauges may be required together with ISO 80369-20 test equipment. For example, a customer may need a Figure C.2 or Figure C.4 reference connector together with a liquid leakage tester, or a Figure C.6 reference connector together with an axial load test setup.
The ISO 80369-7 Luer Gauge Set should therefore be understood as a reference connector and dimensional gauge solution. It is not a complete leakage or axial load test system by itself.
Related ISO 80369-20 Test Equipment
The ISO 80369-7 Luer Gauge Set provides reference connectors and dimensional gauges for Luer connector verification. When functional performance testing is required, such as liquid leakage, subatmospheric air leakage or axial load separation testing, the appropriate ISO 80369-20 test equipment should be selected according to the required test method.
KINGPO can support customers with both ISO 80369-7 reference connectors and ISO 80369-20 test equipment, helping laboratories build a more complete medical small-bore connector test solution.
| Related ISO 80369-20 Equipment | Test Purpose | Typical Use |
|---|---|---|
| ISO 80369-20 Liquid Leakage Tester | Annex B / Annex C liquid leakage testing | Used for checking liquid leakage performance of medical small-bore connectors under specified pressure-related test conditions |
| ISO 80369-20 Annex D Air Leakage Tester | Subatmospheric air leakage testing | Used for evaluating connector air leakage performance under negative-pressure / subatmospheric conditions |
| ISO 80369-20 Annex F Axial Load Tester | Axial load separation testing | Used for checking mechanical retention and separation behavior of medical small-bore connector assemblies under axial force |
| ISO 80369-20 Medical Small-Bore Connector Test Equipment | ISO 80369-20 test equipment selection | Series page for selecting liquid leakage, air leakage and axial load test equipment according to the required test scope |
Typical Applications
The ISO 80369-7 Luer Gauge Set is suitable for laboratories and manufacturers working with Luer connector verification and ISO 80369 related test preparation.
Typical applications include:
- Syringe Luer connector verification
- Needle hub connector checking
- IV cannula and infusion connector inspection
- Luer slip and Luer lock connector R&D validation
- Incoming inspection of connector components
- Factory QC for medical connector assemblies
- Third-party laboratory preparation before ISO 80369 related testing
- Connector comparison during design change or supplier evaluation
For customers handling multiple connector types, a complete ISO 80369-7 Luer Gauge Set can reduce the risk of selecting the wrong reference connector or dimensional gauge.
Technical Features
- Organized as a practical ISO 80369-7 selection set for laboratories handling multiple Luer connector types.
- Supports both reference mating configurations and basic dimensional / fit verification needs.
- Helps customers avoid selecting the wrong connector by separating male Luer, female Luer, Luer slip and Luer lock applications.
- Individual Figure C.1 to C.6 reference connectors can be supplied according to the required test configuration.
- Male Plug Gauge and Female Ring Gauge are available for dimensional and fit checking before further performance testing.
- Can be matched with ISO 80369-20 liquid leakage, air leakage or axial load test equipment when functional testing is required.
- Suitable for R&D verification, incoming inspection, production QC and third-party laboratory test preparation.
- Product datasheet, material information, dimensional confirmation or hardness information can be provided where applicable.
Configuration Notes Before Quotation
To help KINGPO confirm the correct ISO 80369-7 Luer gauge or reference connector configuration, please provide the following information:
- Required standard: ISO 80369-7
- Required item: complete set or individual connector / gauge
- Sample type: male Luer connector or female Luer connector
- Connector type: Luer slip or Luer lock
- Test purpose: reference mating, dimensional check, liquid leakage, air leakage, axial load or other verification
- Whether ISO 80369-20 test equipment is also required
- Whether customized fixtures or adapters are required
- Required documentation: datasheet, material information, dimensional confirmation, calibration or hardness information where applicable
- Quantity and project schedule
This information helps avoid selecting the wrong reference connector, dimensional gauge or ISO 80369-20 test equipment configuration.
Compliance & Regulatory Assurance
-
- Luer Gauge Set is supplied for Luer connector verification according to the customer’s selected ISO 80369-7 test scope and sample type. KINGPO can help confirm whether the project requires Annex C reference connectors, dimensional gauges, ISO 80369-20 test equipment or a combination of these items.
- Because connector testing may involve different mating interfaces, fixtures and documentation requirements, the final configuration should be confirmed before order placement. Product datasheet, configuration information, dimensional confirmation and documentation support can be provided where applicable.
- This page should not be interpreted as a claim that the Luer Gauge Set alone performs all ISO 80369 functional tests. For leakage, air leakage or axial load testing, suitable ISO 80369-20 equipment and test fixtures should be selected.
|
Product Datasheet
ISO 80369-7 Luer Gauge Set and Reference Connectors
Download the PDF datasheet for product overview, quick selection guide, included components, related ISO 80369-20 test equipment and technical inquiry support.
|
Download Datasheet |
Technical Inquiry & Expert Support
For ISO 80369-7 Luer connector verification, KINGPO can help confirm whether you need individual reference connectors, Male Plug Gauge, Female Ring Gauge, a complete Luer Gauge Set or related ISO 80369-20 test equipment.
- Connector type: Luer slip, Luer lock or other small-bore connector
- Sample gender: male connector, female connector or assembled connector
- Required test purpose: reference mating, dimensional check, leakage, air leakage or axial load
- Sample drawing, photos or interface dimensions, if available
- Required documentation: datasheet, dimensional confirmation, hardness or calibration information where applicable
Our team will review your sample and test scope before quotation, helping you select the correct ISO 80369-7 reference connector, dimensional gauge or complete Luer gauge configuration.
ISO 80369-7 Luer Gauge Set and Reference Connectors
FAQ
Related Products
Related News
KingPo supplied ISO 80369-7 Luer Gauges to Angiosistemy LLC in Russia. The gauges are used for laboratory testing of medical […]
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]