KP-1060 Plug Capacitor Discharge Tester
KP-1060 Plug Capacitor Discharge Tester ensures precise IEC-compliant residual voltage measurement with rapid, reliable results.
MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 30 working days
Payment Method: T/T
Supply Capacity: 30 units per month
Capacitor Discharge Tester Description
KP-1060 Capacitor Discharge Tester (Residual Voltage Tester)
The KP-1060 Capacitor Discharge Tester, also known as a Residual Voltage Tester or Plug Capacitor Discharge Tester, is a precision instrument designed to evaluate residual voltage in electrical equipment after disconnection from the power supply. It complies with key international safety standards, including IEC 60601-1 (Medical Electrical Equipment – General Requirements for Safety), IEC 60335-1 (Safety of Household and Similar Electrical Appliances), and their Chinese equivalents GB9706.1 and GB4706.1.
Capacitor Discharge Tester simulates real-world plug disconnection at the voltage peak (positive or negative polarity) using a high-impedance probe (100 ยฑ5 Mฮฉ, capacitance <25 pF) to measure residual voltage and energy decay accurately. It supports manual and automatic testing modes for various pole combinations (L-N, L-G, N-G, pin-to-enclosure, and accessible capacitors). An industrial computer with NI acquisition card (14-bit resolution, 48 kS/s sampling) controls the process, displays results, retains maximum values, and alarms if limits (e.g., >60V or >34V) are exceeded. It includes three standard calibration samples (targeting ~102V, ~70V, ~44V peak) for verification.
Capacitor Discharge Tester Technical Specifications / Data Sheet
- Output Voltage: AC 0โ300V, 50/60 Hz
- Maximum Output Current: โค10A
- Maximum Load Power: 3 kVA
- Power Supply Time: 1โ99 seconds, continuously adjustable
- Test Voltage Range: 10โ300V (resolution 0.1V)
- Test Time / Disconnection Delay: Selectable (e.g., after 1s or 2s); disconnection at voltage peak (ยฑ5% accuracy)
- Number of Measurements: 1โ99 times per combination
- Test Impedance: 100 ยฑ5 Mฮฉ (capacitance <25 pF)
- Polarity Options: Positive or reverse (normal/reversed)
- Acquisition System: Industrial computer control with NI capture card (14-bit resolution, 48 kS/s sampling rate)
- Test Modes: Manual (pole-by-pole, 10 tests per pair); Automatic (all three-pole combinations, 10 tests each)
- Alarm Thresholds: Automatic alarm if residual voltage exceeds 60V or 34V (per standard)
- Additional Features: Maximum voltage retention, multi-form testing (inter-pin, pin-to-housing, accessible capacitors), external test power supply required
- Dimensions: Approximately 3U standard chassis
- Power Consumption: <80W (host)
- Standards Compliance: IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1, GB9706.1, GB4706.1
- Accessories: Includes cables, manual, calibration certificate, and three standard samples
Plug Capacitor Discharge Tester Technical
| Parameter | Specification |
|---|---|
| Output Voltage | AC 0โ300 V, 50/60 Hz |
| Maximum Output Current | โค 10 A |
| Maximum Load Power | 3 kVA |
| Power Supply Time | 1โ99 seconds, continuously adjustable |
| Test Voltage Range | 10โ300 V (display resolution 0.1 V) |
| Test Time / Disconnection Delay | Selectable (e.g., 1 s or 2 s after power-off); disconnection time optional |
| Number of Measurements | 1โ99 times per combination (arbitrary value within range) |
| Test Impedance | 100 ยฑ 5 Mฮฉ, capacitance < 25 pF (some sources indicate < 2 pF or โ 25 pF) |
| Peak Detection & Disconnection Accuracy | Disconnects at voltage peak (ยฑ5% of supply voltage peak); positive or reverse polarity optional |
| Acquisition System | Industrial computer control + NI capture card: 14-bit resolution, 48 kS/s sampling rate |
| Test Modes | Manual (individual pole pairs, e.g., 10 tests per pair); Automatic (all three-pole combinations, 10 tests each) |
| Supported Tests | A. Residual voltage between power pins B. Residual voltage between power pins and enclosure C. Residual voltage & energy on accessible external capacitors |
| Alarm Function | Automatic alarm if residual voltage exceeds 60 V or 34 V |
| Maximum Value Retention | Automatically retains the highest measured residual voltage |
| Calibration Samples | Equipped with three standard inspection samples (target peaks โ102 V / 70 V / 44 V) |
| Power Supply | External test power supply required |
| Dimensions | Approx. 3U standard chassis (some references mention 4U rack mount) |
| Standards Compliance | IEC 60601-1, IEC 60335-1 (Clause 22.5), IEC 61010-1, IEC 62368-1, GB9706.1, GB4706.1 |
| Additional Features | High-impedance simulation of plug disconnection at peak voltage for accurate, consistent residual voltage/energy testing |
Call to Action
Ensure your products meet global safety standards with the reliable KP-1060 Capacitor Discharge Tester. Contact KingPo Technology today for a personalized quote, demonstration, or to place an order. Visit our website or email [email protected] to get started and protect your brand with precise, standards-compliant testing.
Capacitor Discharge Tester Applications
- Safety compliance testing for medical electrical equipment (e.g., diagnostic devices, patient monitors) to ensure residual voltage meets IEC 60601-1 limits after unplugging.
- Verification of household and similar appliances (e.g., kitchen tools, audio/video equipment, power tools) per IEC 60335-1 Clause 22.5.
- Residual voltage and energy discharge assessment for accessible capacitors in IT equipment, laboratory instruments, and other plug-connected devices.
- Quality control, product development, certification labs, and production line testing in industries requiring electrical safety validation.
Technical Parameters
How to use Capacitor Discharge Tester
Plug Capacitor Discharge Tester Detail Display
Capacitor Discharge Tester FAQs
Related Products
Related News
Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]
ISO 80369-7:2021 โ Dimensional and Performance Standards for Luer Connectors and Reference Gauges In medical device engineering, small-bore connector integrity […]