Place of Origin China Brand Name Kingpo
Certification iso9001 Ce Model Number KP-20653
Power Supply: Single Phase AC380V,50Hz Water Tank Size: 650×600×1450mm(L*W*H)
Drip Area: 1000×600mm(L*W*H), customizable Drip Height: 200mm~2850mm Adjustable
Highlight: Ingress Protection Test Equipment, Single phase IP Testing Equipment, Single phase Water Ingress Testing Equipment

IP Standard Codes

  • IPX1: Protected against falling water Equivalent to 3-5mm rainfall per minute for a duration of 10 minutes.
  • IPX2: Protected against falling water when tilted up to 15 degrees – Same as IPX1 but unit is tested in 4 fixed positions – tilted 15 degrees in each direction from normal operating position.
  • IPX3: Protected against spraying water – Water spraying up to 60 degrees from vertical at 10 liters/min at a pressure of 80-100kN/m2 for 5 min.
  • IPX4: Protected against splashing water – Same as IPX3 but water is sprayed at all angles.
  • IPX5: Protected against water jets – Water projected at all angles through a 6.3mm nozzle flow rate of 12.5 liters/min at a pressure of 30kN/m2 for 3 minutes from a distance of 3 meters.
  • IPX6: Protected against heavy seas – Water projected at all angles through a 12.5mm nozzle at a flow rate of 100 liters/min at a 100kN/m2 pressure for 3 minutes from a distance of 3 meters.
  • IPX7: Protected against water immersion – Immersion for 30 minutes at a depth of 1 meter.
  • IPX8: Protected against water submersion – Equipment suitable for continual submersion in water under conditions as specified by manufacturer.
  • IP1X: Protected against solid foreign objects of 50 mm diameter and greater.
  • IP2X: Protected against solid foreign objects of 12.5 mm diameter and greater.
  • IP3X: Protected against solid foreign objects of 2.5 mm diameter and greater.
  • IP4X: Protected against solid foreign objects of 1.0 mm diameter and greater.
  • IP5X: Dust-protected – Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety.
  • IP6X: Dust-tight – No ingress of dust.

Get Free Quote of Ingress Protection (IP) Testing Equipment

Parameters

SOLID INGRESS/ WATER INGRESS NO PROTECTION UNKNOWN PROTECTION >50 MM PROTECTION (HAND) >12.5 MM PROTECTION (FINGER) >2.5 MM PROTECTION (TOOL) >1 MM PROTECTION (WIRE) DUST PROTECTED DUST-TIGHT
No Protection IP00 IPX0 IP10 IP20 IP30 IP40 IP50 IP60
Unknown Protection IP0X IPXX IP1X IP2X IP3x IP4X IP5X IP6X
Dripping Water IP01 IPX1 IP11 IP21 IP31 IP41 IP51 IP61
Dripping Water with tilt up to 15o IP02 IPX2 IP12 IP22 IP32 IP42 IP52 IP62
Spraying Water IP03 IPX3 IP13 IP23 IP33 IP43 IP53 IP63
Splashing Water IP04 IPX4 IP14 IP24 IP34 IP44 IP54 IP64
Water Jet IP05 IPX5 IP15 IP25 IP35 IP45 IP55 IP65
Powerful Water Jet IP06 IPX6 IP16 IP26 IP36 IP46 IP56 IP66
Immersion at less than 1m depth IP07 IPX7 IP17 IP27 IP37 IP47 IP57 IP67
Immersion at depth of 1m or more IP08 IPX8 IP18 IP28 IP38 IP48 IP58 IP68

Specification Parameters

Project name Specification parameters
Equipment Power Supply Specifications Equipment power AC380V 50Hz 4kw
Sample Power Supply Specification AC220V 16A
LWGYD-4 flow sensor Flow range :0.667-4.167 L/min, pulse output
LWGYD-15 flow sensor Flow range :10.00-100.00 L/min, pulse output
Big pumps 380VAC 50Hz 2.2kw protection grade: IP55 insulation grade: F
Mini Pumps 380VAC 50Hz 0.55kw protection grade: IP55 insulation grade: F
Scope of waterproof test IPX1,IPX2,,IPX3,IPX4,,IPX4K,IPX4K,IPX5,IPX6,IPX6K,

IPX7,IPX8,JIS R1/R2,JIS S1/S2

IPX1-IPX2 Drop area :1000*1000 mm
Drop hole diameter :0.4 mm
Drop hole spacing :20 mm
Test flow :1~1.5 mm/min (IPX1),3~3.5(IPX2)
IPX3-IPX4 Swing radius R400mm ,R600mm ,R800mm ,R1000mm
Inner diameter of pendulum tube Φ18mm
Pinhole diameter of pendulum tube Φ0.4mm, hole spacing 50 mm ,0.07±0.0035 L/Min per hole
Swing Rainfall According to the test standard set on the console (water supply 0.63-10 L/Min)
Test time Set on console according to test criteria (range 1-9999 seconds)
Swing tube test angle 0-3500
Swing tube test speed About 4-60 degrees per second
Speed of swing tube turntable According to the standard, the pre-factory system has been set to 1 RPM, or 1 rpm
Custom testing Any set within the º of :0-350

Test speed :4-60 degrees per second set; unit: degrees per second

Test time :0-9999 seconds; set in seconds

Test flow rate :0.63-10.0 L/min set arbitrarily in L/min unit

Sprinkle water Number of fountains 121,φ0.5 holes
Test flow 10±0.5 L/min
Test time Set by test standard (range 1-9999 seconds) in seconds
Test pressure 50-150 kPa
IPX5-IPX6 nozzle aperture 6.3 mm (IPX5),12.5 mm (IPX6)
Water spray 12.5±0.625 L/min (IPX5),100±5 L/min (IPX6)
Test time Set by test standard (range 1-9999 seconds) in seconds
Test pressure Water flow regulation IPX5 about 30 kpa ,IPX6 about 100 kpa
IPX7 Test requirements The lowest point of the shell with 1. height less than 850 mm shall be less than 1000 mm; above the water surface

The highest point of the enclosure 2. a height greater than or equal to 850 mm shall be 150 mm; below the surface of the water

Test time 30 min
IPX4K Swing radius R200mm,R400mm,R600mm,R800mm
Inner diameter of pendulum tube Φ22mm
Pinhole diameter of pendulum tube Φ0.8mm 0.6 L/min±5 per cent per hole
Angle of pendulum test 360°(±180° actual ±175)
Test speed of pendulum tube s/Cycle 12
Swing Rainfall 7.2-30 L/min±5% set
Test time min 10(1 position 5 min,90°5)
Water pressure 400 kPa
Speed of turntable 1RPM
IPX6K Nozzle diameter Φ6.3mm
Test flow 75L/min±5 per cent
Test time 0-99999.9 s Set
Spray pressure 1000 kPa
Turnover Speed range Tilt 15° RPM 1-20
Adjust height mm 800-1700
Dimensions of Water Supply and Control System W1310mm×D890mm×H1600mm

Detail Display - Ingress Protection (IP) Testing Equipment

Related Products

Related News

IP testing equipment checks product resistance to dust and water, ensuring safety, reliability, and compliance with industry standards from KingPo.

IPX9K represents one of the highest levels of water ingress protection in the IEC 60529 and ISO 20653 standards. It […]

Quick FAQ What is a Dust Chamber used for? A Dust Test Chamber is used to simulate controlled dusty environments […]

Dust chamber testing procedures assess product durability by simulating dusty environments, ensuring compliance, reliability, and reduced failure risks.

IP (Ingress Protection) ratings are enclosure protection standards developed by the International Electrotechnical Commission (IEC), primarily assessing the ability of […]

A dust test chamber simulates dusty environments to assess product durability, ensuring devices meet standards and perform reliably in harsh conditions.
IP ratings explained: Understand each code, what the digits mean, and how to choose the right protection level for electronics in any environment.
KINGPO guides manufacturers through IP and IK protection testing for product certification, ensuring compliance, safety, and faster global market access.
Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.