IEC 60601 Programmable Leakage Current Tester โ€“ KingPo Medical Electrical Safety Test Equipment
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo 5.6-inch TFT Display and Control Interface
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo AC/AC+DC/PEAK/DC Measurement Modes
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo Excel Export via U-Disk
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo Medical Electrical Safety Test Equipment
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo 5.6-inch TFT Display and Control Interface
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo AC/AC+DC/PEAK/DC Measurement Modes
IEC 60601 Programmable Leakage Current Tester โ€“ KingPo Excel Export via U-Disk

IEC 60601-1 Programmable Leakage Current Tester | Medical Electrical Safety Test Equipment

IEC 60601-1 Programmable Leakage Current Tester performs medical electrical safety testing with multiple leakage current modes.

  • Standard Compliance: IEC60601-1, IEC61010-1, IEC60335-1, IEC60950-1, IEC60065, IEC60598-1, IEC60990 โ€“ medical and household electrical safety testing
  • Measurement Modes: AC, AC+DC, PEAK, DC โ€“ four detection methods
  • Current Ranges: 20 ฮผA / 200 ฮผA / 2 mA / 20 mA with programmable upper/lower limits
  • Display: 5.6-inch TFT (640ร—480) for clear setting and test parameters
  • Data Storage: Excel format export via U-disk with software upgrade support
  • Interfaces: RS232, PLC, optional LAN/RS485/USB and scan code gun
  • Auxiliary Power: Built-in isolated supply for medical equipment testing
  • MOQ: 1
  • Delivery Period: 30 working days

Programmable Leakage Current Tester Description

IEC 60601 Programmable Leakage Current Tester | Medical Electrical Safety Test Equipment

The IEC 60601 Programmable Leakage Current Tester | Medical Electrical Safety Test Equipment is a high-precision, multi-standard safety tester manufactured by KingPo. It is designed for automated leakage current (touch current and protective conductor current) measurement on medical electrical equipment and other electrical products in accordance with IEC60601-1 and multiple related international safety standards.

Technical Parameters

Parameter Specification Remark / Notes
Standard IEC60601-1, IEC61010-1, IEC60335-1, IEC60950-1, IEC60065, IEC60598-1, IEC60990 Multiple human body networks supported
Display 5.6-inch TFT (640ร—480) Eye-catching and information-rich interface
Leakage Current Modes AC, AC+DC, PEAK, DC Four detection methods
Current Ranges 20 ฮผA / 200 ฮผA / 2 mA / 20 mA Programmable upper/lower limits
Voltage Range 30.0 V โ€“ 300.0 V ยฑ(2% reading + 2 V) precision
Test Time 0.0 or 0.3โ€“999.9 s 0 = continuous test
Interval Time 0.0โ€“999.9 s 0 = interval off
Data Storage Excel format via U-disk Support for file conversion and scan code gun
Interfaces RS232, PLC standard; optional LAN/RS485/USB Easy integration into automated test systems
Power Supply AC 220 V ยฑ10%, 50 Hz, 500 W Single-phase laboratory power

 

Professional Construction & Technical Precision

The tester features a compact, robust enclosure with a high-resolution 5.6-inch TFT color display for clear, real-time visualization of test parameters and results. Precision measurement circuits support four leakage current modes with dedicated human body impedance networks that accurately simulate physiological response. The internal high-isolation auxiliary power supply ensures safe testing of medical devices without external interference.

Programmable test sequences, multi-step file management and U-disk Excel export capability enable efficient data handling in production or laboratory environments. Safety features include keyboard lock to prevent unauthorized changes, automatic pass/fail judgment and comprehensive interface options (RS232, PLC, optional LAN/RS485/USB) for seamless integration into automated test lines. This combination of hardware precision and software flexibility delivers repeatable, traceable and audit-ready leakage current measurements.

Testing Principle

The instrument applies a test voltage (30โ€“300 V) to the equipment under test and measures the resulting leakage current flowing through simulated human body networks. Four detection modes (AC, AC+DC, PEAK, DC) are available to capture different leakage characteristics. The system automatically compares measured values against programmable upper and lower limits and records results for compliance evaluation.

Common Error Mitigation

To ensure repeatable and accurate results, always verify that the correct human body network is selected for the applicable standard and that test leads are securely connected with no stray capacitance. Regular calibration of voltage and current channels, together with verification of auxiliary power isolation, prevents measurement drift and ensures compliance data remains defensible during audits.

Primary Use Cases & Business Value

The IEC 60601- Programmable Leakage Current Tester is used for safety verification of medical electrical equipment during design validation, production line testing and third-party certification. It enables manufacturers to confirm compliance with stringent leakage current limits, reduce patient safety risks and accelerate regulatory approval for medical devices.

Industrial Applications & Lab Scenarios

  • Medical device manufacturers โ€“ production-line leakage current testing of patient-contact equipment per IEC60601-1
  • Third-party certification laboratories โ€“ traceable compliance testing according to IEC60601-1 and multiple household/medical safety standards
  • R&D departments โ€“ precise evaluation and optimization of insulation and grounding designs for new medical products
  • Quality control teams โ€“ high-throughput batch testing of electrical medical devices and household appliances
  • Automated test system integrators โ€“ integration via PLC/RS232/LAN interfaces for fully automated production safety testing

Strategic Procurement Advantages & Global Support

  • High-Efficiency Testing: Featuring four leakage current modes, programmable multi-step sequences and 5.6-inch TFT display, this system delivers fast, repeatable medical safety test results with minimal operator intervention.
  • Certified Manufacturing: As an ISO 9001/14001/45001 and CE certified manufacturer with SGS, PSE, and RoHS credentials, KingPo ensures that every tester is built to the highest international quality benchmarks.
  • Reliability & Support: Each unit undergoes rigorous factory calibration in our Dongguan facility and is backed by a full one-year warranty, on-site installation guidance, and lifetime technical engineering support to ensure long-term laboratory ROI.

Compliance & Regulatory Assurance

This equipment is designed and manufactured in accordance with IEC60601-1 and multiple related standards (IEC61010-1, IEC60335-1, IEC60950-1, IEC60065, IEC60598-1, IEC60990) for leakage current testing of medical and household electrical equipment. It provides a standardized, traceable method to measure touch current and protective conductor current, ensuring products meet the required patient and user safety levels.

For detailed information on IEC60601-1 leakage current testing, please refer to the latest edition of IEC60601-1. Regular verification of measurement circuits and human body networks is recommended to maintain traceability.

Technical Inquiry for IEC 60601 Programmable Leakage Current Tester

KingPo specializes in electrical safety testing equipment. If you require precise IEC60601-1 leakage current testing for medical devices, our engineering team can provide technical support and configuration recommendations.

The Core Value We Deliver to You

  • Four leakage current modes (AC / AC+DC / PEAK / DC) with programmable limits
  • 5.6-inch TFT display and U-disk Excel data export
  • Built-in auxiliary power supply for medical equipment testing
  • Multiple interfaces including RS232, PLC and optional LAN/RS485/USB
  • Keyboard lock and multi-step file management for production efficiency

Tell us your medical device type or specific leakage current requirements โ€” our engineering team will reply with tailored recommendations within 24 hours.

Related Category

Category Item Specifications
Model Model No. CS9975-SIW
Leakage Current Parameters Test Voltage Range 30.0V๏ฝž300.0V
Voltage Precision ยฑ(2% reading + 2V)
Voltage Resolution 0.1V
Max External Isolated Power Supply 6000VA
Current Gears 20ฮผA, 200ฮผA, 2mA, 20mA
Detection Method AC, RMS, PEAK, DC
Current Upper Limit Setting Range 0.1ฮผA๏ฝž20.00mA
Current Lower Limit Setting Range 0.0ฮผA ๏ฝž Pre-set upper current limit
Applicable Safety Standards GB9706.1(IEC60601-1)

GB4793.1(IEC61010-1)

GB4706.1(IEC60335-1)

GB4943.1(IEC60950-1)

GB8898(IEC60065)

GB7000.1(IEC60598-1)

GB/T12113(IEC60990)

Voltage Rise Time Non-adjustable
Test Duration Range (0.3๏ฝž999.9)s; 0 = continuous continuous test mode
Test Interval Range (0.0๏ฝž999.9)s; 0 = interval function disabled
Leakage Current Meter Measuring Current Range 0.0ฮผA ๏ฝž 20.00 mA
Current Resolution 20ฮผA range: 0.1ฮผA

200ฮผA range: 0.1ฮผA

2mA range: 1ฮผA

20mA range: 10ฮผA

Measurement Accuracy
AC Accuracy Iโ‰ฅ5 ฮผA: ยฑ(2%rdg+0.5%fs)

Iโ‰ฅ50 ฮผA: ยฑ(2%rdg+0.5%fs)

DC Accuracy Iโ‰ฅ5 ฮผA: ยฑ(2%rdg+0.5%fs)

Iโ‰ฅ50 ฮผA: ยฑ(2%rdg+0.5%fs)

AC+DC Accuracy Iโ‰ฅ5 ฮผA: ยฑ(2%rdg+0.5%fs)

Iโ‰ฅ50 ฮผA: ยฑ(2%rdg+0.5%fs)

PEAK Accuracy Iโ‰ฅ50 ฮผA: ยฑ(2%rdg+2%fs)
Leakage Voltage Meter Voltage Measuring Range 30.0V๏ฝž300.0V
Voltage Precision ยฑ(2% reading + 2V)
Voltage Resolution 0.1V
Display Mode Root Mean Square (RMS) value
Timing Function Timing Range 0๏ฝž999.9s
Timing Resolution 0.1s
Timing Precision ยฑ(1% reading + 50ms)
System & Storage Memory Groups 30 groups
Max Test Steps per Group 99 steps
Power Supply Working Input Voltage 220Vยฑ10%, 50Hz
File Function USB Memory File Import & Export Supported
Export Test Data to USB Flash Drive Supported
Communication Interface Standard Interfaces RS232 interface, PLC interface

Detail Display

Programmable Leakage Current Tester FAQs

What types of equipment is the IEC 60601 Programmable Leakage Current Tester suitable for?
The tester is designed for medical electrical equipment, household appliances and other electrical products requiring leakage current safety verification per IEC60601-1 and related standards.
Which standards does the programmable leakage current tester comply with?
It fully supports IEC60601-1, IEC61010-1, IEC60335-1, IEC60950-1, IEC60065, IEC60598-1 and IEC60990 human body networks.
How many leakage current measurement modes does the IEC 60601 tester provide?
Four modes are available: AC, AC+DC, PEAK and DC, allowing comprehensive analysis of different leakage characteristics.
What current ranges are supported by the medical leakage current tester?
Four ranges are provided: 20 ฮผA, 200 ฮผA, 2 mA and 20 mA, each with programmable upper and lower limits.
Does the IEC 60601 leakage current tester support automated data export?
Yes. Test results can be saved directly in Excel format to a U-disk for easy reporting and traceability.
Can the tester be integrated into automated production lines?
Yes. It offers standard RS232 and PLC interfaces, with optional LAN/RS485/USB for full automation.
What maintenance is required for the programmable leakage current tester?
Periodic calibration of voltage and current channels, cleaning of test leads and verification of auxiliary power isolation ensure long-term accuracy.
What are the installation environment requirements for the IEC 60601 tester?
The instrument should be placed in a clean, stable laboratory with AC 220 V ยฑ10% power supply and proper grounding.
How frequently should the IEC 60601 Programmable Leakage Current Tester be calibrated?
Annual calibration of measurement circuits and human body networks is recommended to maintain traceability and compliance.
How can I request a quotation for the IEC 60601 Programmable Leakage Current Tester?
Provide your medical device type or specific leakage current test requirements; our engineering team will return a competitive quotation within 24 hours.

Related Products

Related News

Abstract & Technical Summary Per BS 1362:1973+A3:2021 general purpose fuse links specification, BS 1363-1:2023 13 A rewirable and non-rewirable fused […]

IEC 62368-1 Clause 9.6.2 Wireless Charging Foreign Object Temperature Rise Test Kit streamlines compliance, ensuring safe and certified wireless charging devices.
Ensure ISO 14117 compliance for AIMDs by using a Defibrillation Test Pulse Generator to meet safety standards and document reliable defibrillation immunity testing.
Ensure IEC 60601 compliance in 2026 with Defib-proof and Energy Reduction Tester for safer, faster medical device approval and reliable patient protection.

Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]

Compare KP8850 and QA-ES III ESU Analyzers for accuracy, workflow, compliance, and usability to choose the right ESU Analyzer for your clinical or lab needs.

Conflict of interest disclosure: This is a firstโ€‘party, engineeringโ€‘style review of the Kingpo KPโ€‘8850 ESU analyzer. We aim to be […]

Shan Chao 1 , Qiang Xiaolong 2 , Liu jiming 3 , Zhang Chao 3 . (1. Heilongjiang Institute for […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.