Implantable Surge Tester 140-380V for Medical Device Testing
Implantable Surge Tester 140-380V for Medical Device Testing

Implantable Surge Tester 140-380V for Medical Device Testing

The KP-1680S Implantable Surge Tester (140-380V) simulates electrical surges to ensure medical device safety and ISO14708-1 compliance.

  • Standard Compliance: ISO14708-1:2014, EN 45502-2-2:2008 – Direct reference for implantable device surge testing
  • Surge Voltage: 140V and 270V peak, adjustable
  • Rise Time: 1.5ms ≤ Tp ≤ 2.5ms
  • Polarity Control: Positive/Negative, alternating via USB
  • Control Modes: Manual knob or USB computer control with auto-trigger
  • MOQ: 1
    Price: To be quoted
    Standard Packaging: 600*600*500
    Delivery Period: 30 day
    Payment Method: T/T

Detail Information

Place of Origin China Brand Name Kingpo
Certification Iso9001 Ce Model Number KP-1680S-Test2
Rise Time: 1.5ms ≤ Tp ≤ 2.5ms Optional USB TestMinder: Computer Control With Auto-trigger Via USB
Warranty: One Year Product Name: Implantable Surge Tester Damped Sinus 140-380V
Front Panel Meter: Indicates Test Peak Open Circuit Voltage And Polarity Voltage Control: Manually, By Turning A Knob In The Front Panel Or Via USB
Polarity Control: Positive And Negative. Alternating Control Available With USB Voltage Meter Accuracy: ±4V
Highlight: Polarity Implantable Surge Tester, 140-380V Implantable Surge Tester, Implantable Surge Tester

Product Description

The KP-1680S-Test2 Implantable Surge Tester is a state-of-the-art solution designed for testing the reliability and safety of implantable medical devices. Engineered to simulate electrical surge conditions, this advanced tester ensures that devices such as pacemakers and defibrillators withstand real-world challenges, meeting stringent international standards like ISO14708-1:2014 and EN 45502-2-2:2008. With its user-friendly interface, robust design, and comprehensive data logging, the KP-1680S-Test2 is the ultimate choice for manufacturers and laboratories aiming to enhance patient safety and device performance.

Get Free Quote of Implantable Surge Tester 140-380V for Medical Device Testing

We provide high-precision Implantable Surge Tester 140-380V direct from KingPo factory, ensuring reliable defibrillation surge testing per ISO14708-1 & EN 45502.

The Core Value We Deliver to You

  • Exact standard compliance – 140V/270V peak with 1.5–2.5ms rise time
  • High Reliability – 20s recharge, ±4V accuracy for repeatable results
  • Factory Advantages – MOQ 1 unit, 15-day delivery, 1-year warranty, ISO9001 & CE
  • Complete Testing Support – Pair with our medical series for full checks
  • Faster Certification – Identify surge risks early, reduce failures

Take Action Now – Submit inquiry in 30 seconds for best price, stock status, and technical support within 24 hours!

Product Attributes

Attribute Value
Rise Time 1.5ms ≤ tp ≤ 2.5ms
Optional USB TestMinder Computer control with auto-trigger via USB
Warranty One year
Product Name Implantable Surge Tester Damped Sinus 140-380V
Front Panel Meter Indicates test peak open circuit voltage and polarity
Voltage Control Manually, by turning a knob in the front panel or via USB
Polarity Control Positive and Negative. Alternating control available with USB
Voltage Meter Accuracy ±4V

Key Features

  • Adjustable Surge Levels: Supports testing at 140V and 270V peak voltages, compliant with ISO14708-1:2014, EN 45502-2-1:2003, EN 45502-2-2:2008, and EN 45502-2-2-3:2010.
  • Multiple Testing Modes: Includes positive and negative polarity testing, selectable via a front panel switch or optional computer control for automated test sequences.
  • Truncated Exponential Waveform: Outputs precise pulse waveforms for defibrillation-proof testing of implantable devices, with internal resistor networks as per standard requirements.
  • Fast Recharge Cycle: Recharges and triggers the next pulse in 20 seconds, ensuring efficient testing workflows.
  • Comprehensive Data Logging: Records test results for thorough analysis, supporting compliance documentation and quality assurance.
  • Compact and Durable Design: Measures 600×600×500 mm, built to withstand a 6-inch drop, ideal for both laboratory and field testing.
  • Certified Quality: ISO9001 and CE certified, with calibration certificate included.

Applications

  • Implantable Medical Device Testing: Ensures pacemakers, defibrillators, and other implants meet surge resistance standards.
  • Compliance Testing: Validates devices against ISO14708-1:2014 (140V peak), EN 45502-2-2:2008 (270V peak), and other EN 45502 standards.
  • Research and Development: Helps engineers identify design weaknesses in implantable devices.
  • Production Line Testing: Streamlines quality control for medical device manufacturers.

Technical Specifications

Model KP-1680S-Test2
Surge Voltage 140V and 270V peak
Pulse Recharge Time 20 seconds
Testing Modes Positive/Negative polarity, manual/computer control
Dimensions 600×600×500 mm
Weight Approx. 15 kg
Certifications ISO9001, CE
Warranty 1 year
MOQ 1 unit
Price $7,000 (EXW)
Delivery Time 30 days
Payment Terms T/T
Supply Capacity 10,000 units

Why Choose KingPo's KP-1680S-Test2?

  • Standards Compliance: Meets ISO14708-1:2014, EN 45502-2-1:2003, EN 45502-2-2:2008, and EN 45502-2-2-3:2010 for reliable testing.
  • User-Friendly Interface: Simplifies test setup and real-time monitoring, reducing training time.
  • Robust and Versatile: Compact design suitable for lab and field use, with rugged construction for durability.
  • Trusted by Industry Leaders: Backed by KingPo’s reputation, with endorsements from SGS and TÜV Rheinland.

How It Works

The KP-1680S-Test2 generates a truncated exponential waveform to simulate electrical surges that implantable medical devices may encounter. The tester supports:

  1. Surge Simulation: Applies 140V or 270V peak surges to test device resilience.
  2. Polarity Switching: Allows positive and negative polarity testing via a front panel switch or computer control.
  3. Data Analysis: Logs surge parameters and device responses for compliance reporting.
  4. Automated Sequencing: Optional computer control automates test sequences per standard requirements.

Implantable Surge Tester 140-380V FAQs

How does the Implantable Surge Tester simulate real defibrillation surges?
It generates damped sinusoidal pulses at 140V/270V peak with 1.5–2.5ms rise time, matching ISO14708-1:2014 & EN 45502-2-2 requirements for implantable devices.
Can this tester handle both positive and negative polarity testing?
Yes – polarity is selectable via front panel switch or USB control, with alternating mode available for automated sequences.
What if my lab needs computer control – is USB integration reliable?
Yes – optional USB TestMinder provides auto-trigger and data logging, ideal for high-volume or scripted testing.
How does the ±4V voltage accuracy benefit compliance testing?
The high precision minimizes measurement errors, ensuring reliable surge withstand data for ISO14708-1 & EN 45502 submissions.
What is the recharge time and how does it affect workflow?
20 seconds recharge cycle allows fast, efficient testing without long waits, suitable for production line or lab use.
What warranty and support does KingPo offer?
1-year warranty plus lifetime technical support for long-term reliability.
How does this tester help reduce risks in implantable devices?
It identifies surge vulnerabilities early, preventing insulation breakdown or leakage in pacemakers/defibrillators during real defibrillation events.
Can the tester be used for custom surge levels in R&D?
Yes – manual knob and USB control allow adjustment beyond standard 140V/270V for prototype testing.
How long does a typical surge test cycle take?
A single cycle (setup + surge + recharge) takes under 1 minute, saving lab time compared to manual methods.
How to get a quote or sample for the Implantable Surge Tester 140-380V?
Submit the inquiry form or email [email protected] for pricing and fast support.

Related Products

Related News

Ensure ISO 14117 compliance for AIMDs by using a Defibrillation Test Pulse Generator to meet safety standards and document reliable defibrillation immunity testing.
Ensure IEC 60601 compliance in 2026 with Defib-proof and Energy Reduction Tester for safer, faster medical device approval and reliable patient protection.

The Defibrillation Immunity Testing Requirements for Active Implantable Medical Devices (AIMDs): Standards Breakdown, Visual Insights, and Recommendation for the KP-1050S […]

External defibrillators are performance‑critical devices. For third‑party calibration and certification laboratories—and for manufacturers’ QA/production teams—the “make or break” is whether […]

Conflict of interest disclosure: This is a first‑party, engineering‑style review of the Kingpo KP‑8850 ESU analyzer. We aim to be […]

Shan Chao 1 , Qiang Xiaolong 2 , Liu jiming 3 , Zhang Chao 3 . (1. Heilongjiang Institute for […]

IEC 60601-2-2 testing devices for neutral electrodes verify safety, compliance, and help secure medical device approval by measuring key parameters.
ISO 80369 test equipment checks medical connectors for compliance, preventing misconnections and ensuring patient safety in healthcare environments.