ISO 8637-2 Conical Gauge for Blood Socket Connector Testing
The KINGPO ISO 8637-2 Conical Gauge is designed for dimensional inspection of blood socket connectors used in extracorporeal blood purification systems. The KP-8637F3 features precision-defined 6:100 conical geometry, a specified 5 N inspection force, and hardened 440C stainless steel construction. It supports connector dimensional verification in medical device manufacturing, quality control and laboratory testing.
- Model: KP-8637F3
- Applicable Standard: ISO 8637-2
- Test Object: Blood Socket Connector
- Primary Use: Conical dimensional inspection and engagement verification
- Specified Inspection Force: 5 N
- Taper Ratio: 6:100
- Material: 440C Stainless Steel
- Hardness: HRC 58–60
- Surface Roughness: Ra ≤ 0.8 μm on critical surfaces
- Typical Applications: Extracorporeal blood circuit manufacturing, connector inspection and laboratory verification
ISO 8637-2 Conical Gauge
Product Overview
Reliable connections in extracorporeal blood circuits depend on accurately manufactured mating surfaces. Conical connectors must maintain their specified geometry to achieve the intended engagement with corresponding blood ports.
The KP-8637F3 Conical Gauge provides a precision-defined mating reference for inspecting the conical geometry of blood socket connectors associated with ISO 8637-2.
Its 6:100 taper geometry and specified 5 N inspection force support controlled assessment of dimensional engagement. By using a reference gauge with defined dimensions, laboratories and manufacturers can evaluate connector geometry against the applicable dimensional requirements.
The gauge is manufactured from 440C stainless steel, with a specified Rockwell hardness of HRC 58–60 and a surface roughness not exceeding Ra 0.8 μm on critical surfaces.
Designed as a mechanical inspection component, the KP-8637F3 does not require an electronic measuring system for its intended gauging function.
Technical Specifications
| Parameter | Specification |
|---|---|
| Product Name | Conical Gauge for Blood Socket Connector Testing |
| Model | KP-8637F3 |
| Applicable Standard | ISO 8637-2 |
| Test Object | Blood Socket Connector |
| Inspection Purpose | Conical dimensional and engagement inspection |
| Specified Force | 5 N |
| Taper Ratio | 6:100 |
| Material | 440C Stainless Steel |
| Rockwell Hardness | HRC 58–60 |
| Critical Surface Roughness | Ra ≤ 0.8 μm |
| Reference Geometry | Conical Reference Connector, Table 3 |
Conical Reference Dimensions
| Parameter | Specification |
|---|---|
| Minimum Gauge Length (e) | 10 mm minimum |
| Testing Dimension Length (f) | 1.24–1.25 mm |
| Reference Dimension Length (g) | 7 mm nominal |
| Taper Dimension (H) | 5.905–5.910 mm |
| Taper Dimension (J) | 6.325–6.330 mm |
| Reference Dimension (K) | 6.405 mm nominal |
| Taper Ratio (γ) | 6:100 |
The defined conical geometry provides a reference for dimensional inspection of blood socket connectors under the specified gauging conditions.
Conical Dimensional Inspection
The KP-8637F3 is used to examine the mating geometry of blood socket connectors. The inspection primarily concerns three characteristics:
Conical Geometry
The gauge incorporates a defined 6:100 taper, allowing the mating cone geometry to be evaluated against specified dimensional limits.
Engagement Position
The engagement between the reference cone and the connector is relevant to determining whether the conical interface falls within the permitted dimensional range.
Dimensional Consistency
A defined gauge geometry provides a consistent reference for inspection activities involving connector development, production verification and quality control.
Dimensional inspection is distinct from functional testing. Liquid leakage, air leakage, separation resistance and other connection performance characteristics require the appropriate test procedures and equipment.
The 5 N Inspection Force
The 5 N inspection force is an important test condition for the KP-8637F3.
The force applied during inspection affects the engagement between the gauge and the connector. Using a specified force helps establish a consistent inspection condition when evaluating connector geometry.
The 5 N value represents the inspection force, not the measuring range of a force tester.
Gauge engagement and dimensional acceptance should be assessed using the procedure required by the applicable ISO 8637-2 edition.
ISO 8637-2 Standard and Test Application
ISO 8637-2 specifies requirements for disposable extracorporeal blood and fluid circuits and associated accessories used with haemodialysis equipment.
These systems are used in extracorporeal blood treatment therapies, including haemodialysis, haemodiafiltration and haemofiltration.
Connector dimensional requirements help establish mechanical compatibility between blood circuit components and their intended mating interfaces.
The KP-8637F3 supports conical dimensional inspection associated with these requirements through its defined reference geometry and 5 N inspection condition.
The gauge is intended for dimensional verification and should not be used as a substitute for separate leakage or mechanical performance tests required for the complete connector assembly.
Typical Laboratory Applications
|
01
Blood Circuit Manufacturing
|
Dimensional inspection of blood socket connectors during production quality control and incoming component inspection. |
|
02
Medical Connector Development
|
Verification of conical geometry and mating engagement during connector design, prototyping and dimensional validation. |
|
03
Medical Device Testing Laboratories
|
Reference gauging for dimensional inspection of blood socket connectors under applicable ISO 8637-2 procedures. |
Compliance & Regulatory Assurance
The KP-8637F3 Conical Gauge is designed for dimensional inspection of blood socket connectors in accordance with the relevant requirements of ISO 8637-2. Its defined 6:100 taper geometry, 5 N inspection condition, and precision-machined 440C stainless steel construction support consistent evaluation of connector dimensions and engagement.
The gauge serves as a dimensional inspection reference within the applicable test procedure. Complete connector conformity assessment must also address any required leakage, mechanical integrity and connection performance tests specified by the relevant standard edition.
Technical Inquiry & Expert Support
For KP-8637F3 inquiries, please share your connector details and inspection requirements to help us confirm the appropriate gauge configuration.
| Applicable Standard | ISO 8637-2 edition and applicable inspection method. |
| Connector Details | Blood socket connector type, dimensions or technical drawing. |
| Inspection Conditions | Required conical geometry, 5 N gauging condition and inspection criteria. |
| Technical Documentation | Dimensional inspection records, material certificates or calibration documentation, as required. |
KINGPO can review your connector drawing and inspection conditions to help determine the appropriate gauge before quotation.
ISO 8637-2 Conical Gauge for Blood Socket Connector Testing
FAQ
Related Products
Related News
Abstract / Technical Summary Accurate dimensional verification is essential for industrial plugs and sockets to meet international safety standards. This […]
Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]
ISO 5356-1:2015 is the internationally recognized standard titled Anaesthetic and respiratory equipment — Conical connectors — Part 1: Cones and […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]
Enhancing Electrical Safety with IEC 60309 Compliance Gauges 20 I see electrical safety as a top priority in every industrial […]