IEC 60335-2-15 Kettle Horizontal and Vertical Movement Apparatus
IEC 60335-2-15 Kettle Movement Test Apparatus is designed for kettle handle durability testing according to IEC 60335-2-15 Clause 21.101. This horizontal and vertical movement apparatus performs repeated movement tests to evaluate whether the kettle handle and fixing structure remain secure after mechanical stress. The apparatus features a 400 mm ± 10 mm pivot distance, 5 mm rubber pad, PLC control, 7-inch HMI touch interface and servo motor drive for stable and repeatable testing.
- IEC 60335-2-15 Kettle Movement Test Apparatus designed for Clause 21.101 kettle handle durability testing
- Suitable for horizontal and vertical movement tests of kettles
- Used to evaluate kettle handle durability and securement strength
- Pivot point to handle grip centre distance: 400 mm ± 10 mm
- Rubber pad thickness: 5 mm
- Rubber hardness: 50 Shore ± 10 Shore
- Horizontal movement test: 90° arc, 2,500 cycles, 10 cycles/minute
- Vertical movement test: 120° motion, 5,000 cycles, 10 cycles/minute
- PLC intelligent control with 7-inch human-machine touch interface
- Servo motor drive for stable and repeatable movement control
IEC 60335-2-15 Kettle Horizontal and Vertical Movement Apparatus Overview
IEC 60335-2-15 Kettle Horizontal and Vertical Movement Apparatus Overview
The IEC 60335-2-15 Kettle Movement Test Apparatus is used to simulate repeated handling and pouring movements of kettles. During testing, the kettle is fixed at the handle grip area, and the apparatus performs controlled horizontal and vertical movement according to the required test condition.
This equipment is mainly used by household appliance manufacturers, electrical safety laboratories, certification preparation teams and quality control departments for kettle durability testing. It helps verify whether the handle, handle fixing parts and kettle body connection remain secure after repeated movement.
The system supports repeatable kettle movement testing for product development, type testing and production quality control.
Technical Parameters
Standard and Test Performance Information
| Parameter | Specification | Remark or Notes |
|---|---|---|
| Product name | IEC 60335-2-15 Kettle Movement Test Apparatus | Horizontal and vertical kettle handle durability test apparatus |
| Model | KP-3515A | Product model |
| Applicable standard | IEC 60335-2-15 Clause 21.101 | Kettle movement test requirement |
| Test object | Electric kettles | Especially handle and fixing structure |
| Test purpose | Handle durability and securement verification | Horizontal and vertical repeated movement |
| Rubber thickness | 5 mm | Contact pad for clamping area |
| Rubber hardness | 50 Shore ± 10 Shore | Rubber contact condition |
| Pivot distance | 400 mm ± 10 mm | Distance between pivot point and centre of handle grip area |
| Horizontal movement test | 90° arc, 2,500 cycles, 10 cycles/minute | Horizontal repeated movement test |
| Vertical movement test | 120° motion, 5,000 cycles, 10 cycles/minute | Vertical repeated movement test |
Control and Equipment Information
| Parameter | Specification | Remark or Notes |
|---|---|---|
| Control method | PLC intelligent integrated control | With 7-inch HMI touch interface |
| Drive mode | Servo motor | For stable horizontal and vertical movement |
| Overall dimensions | 1100 × 1320 × 1580 mm | W × D × H |
| Weight | 180 kg | Approximate equipment weight |
| Typical users | Appliance manufacturers, testing laboratories and QC departments | For IEC 60335-2-15 compliance preparation |
| Documentation support | Specification and inspection support available | Confirm calibration or documentation scope before order |
Testing Principle and Result Evaluation

The IEC 60335-2-15 Kettle Movement Test Apparatus applies defined horizontal and vertical movements to simulate repeated handling stress on kettle handles.
During the test, the kettle is mounted by the handle grip area. The distance between the pivot point and the centre of the grip area is set to 400 mm ± 10 mm. A rubber interface with 5 mm thickness and 50 Shore ± 10 Shore hardness is used to support the required contact condition.

The apparatus then performs the required horizontal and vertical movement sequence. For the horizontal movement test, the kettle is moved through a 90° arc for 2,500 cycles at 10 cycles per minute. For the vertical movement test, the kettle is moved through a 120° motion for 5,000 cycles at 10 cycles per minute.
After testing, the kettle handle, handle fixing area and related structural parts should be inspected. The result is normally acceptable when there is no breakage, cracking, loosening, detachment or other unsafe mechanical failure. Final evaluation should follow IEC 60335-2-15 Clause 21.101 and the laboratory acceptance criteria.
Specimen Preparation and Test Notes

Before using the IEC 60335-2-15 Kettle Movement Test Apparatus, the kettle sample should be inspected to confirm that the handle, body, fixing screws, grip area and related parts are in normal condition. Any pre-existing cracks, looseness or deformation should be recorded before the test.
The kettle should be fixed securely at the handle grip area according to the required test setup. The pivot distance, rubber pad condition, movement angle, cycle count and test speed should be confirmed before starting the test.
During testing, the operator should monitor whether the kettle remains properly fixed and whether the handle or fixing structure shows abnormal movement. After the test, the handle area should be checked carefully for cracks, loosening, deformation or separation from the kettle body.
Common Error Mitigation
Reliable kettle movement testing depends on correct sample mounting, pivot distance adjustment and stable movement control. Laboratories should avoid:
| ● Incorrect positioning of the kettle handle grip area | ● Wrong pivot distance setting |
| ● Using a worn or unsuitable rubber pad | ● Incorrect rubber hardness or rubber thickness |
| ● Setting the wrong movement angle | ● Setting the wrong number of cycles |
| ● Running the test at the wrong movement speed | ● Failing to tighten the handle fixture properly |
| ● Ignoring handle looseness during testing | ● Recording only pass/fail results without noting visible damage or loosening |
Maintenance and Documentation Support
|
The handle fixture, pivot mechanism, rubber pad, servo drive, moving arm and fastening parts should be inspected regularly. Worn rubber pads, loose fixtures or unstable movement may affect test repeatability. After testing, the working area should be cleaned, and the moving mechanism should be checked for abnormal noise, looseness or wear. The rubber contact pad should be replaced when it becomes worn, hardened, damaged or deformed. |
For formal laboratory use, recommended documentation includes:
● Equipment specification
● Inspection or calibration record ● Rubber pad thickness and hardness record ● Pivot distance setting record ● Horizontal movement angle and cycle record ● Vertical movement angle and cycle record ● Test speed record ● Sample mounting photo ● Handle and fixing area inspection record ● Final test report according to laboratory procedure |
Standards Compliance Notes
This IEC 60335-2-15 Kettle Movement Test Apparatus is designed to support IEC 60335-2-15 Clause 21.101 kettle horizontal and vertical movement testing. Final compliance should be evaluated according to the official standard and the laboratory’s test procedure.
The equipment should be described as a test apparatus for supporting IEC 60335-2-15 kettle horizontal and vertical movement testing, not as a product certification result. If formal documentation or calibration support is required, the certificate scope and covered parameters should be confirmed before ordering.
Technical Inquiry & Configuration Support
Before requesting a quotation, customers are recommended to provide the following information:
- Applicable standard: IEC 60335-2-15 Clause 21.101 or internal test method
- Kettle type and sample size
- Handle structure and grip area dimensions
- Required horizontal movement angle and cycle count
- Required vertical movement angle and cycle count
- Required pivot distance setting
- Local power supply
- Required documentation or calibration support
- Delivery schedule
- Packaging and shipping requirement
Based on this information, KingPo can confirm whether the KP-3515A IEC 60335-2-15 Kettle Movement Test Apparatus is suitable for the customer’s kettle handle durability testing requirement.
IEC 60335-2-15 Kettle Horizontal and Vertical Movement Apparatus
IEC 60335-2-15 Kettle Horizontal and Vertical Movement Apparatus FAQs
Related Products
Related News
KingPo supplied an IEC 60335-1 Clause 19 Battery Short Circuit Tester to TSK Corporation for a laboratory project in South […]
KingPo Eurofins IEC 60335 Test Equipment Delivered to Finland Espoo, Finland — Jun 2023 —A complete set of high-precision IEC 60335 […]
KingPo HCT IEC 60335 Test Equipment Delivered to Korea Seoul, Korea — Jun 2021 — High-precision KingPo HCT IEC 60335 test […]
KingPo Delivers IEC 60335 Test Equipment to Intertek Hong Kong and Korea Hong Kong & Seoul, March 2023 — KingPo […]
KingPo UL Vietnam IEC 60335 Test Equipment Delivered for IEC 62368-1 Compliance Hai Duong Province, Vietnam — KingPo is […]
Introduction: The Hidden Threat in Your Devices Every year, thousands of residential and industrial fires are traced back to a […]