ISO 18250-3 Figure C.3 Reference Connector
The ISO 18250-3 Figure C.3 Reference Connector is a stainless steel reference connector used for reservoir delivery system connector test setups. It is mainly applied when cross-port reservoir connectors need to be evaluated for leakage, stress cracking, unscrewing resistance and disconnection-by-unscrewing performance under the selected ISO 18250-3 requirements.
- Applicable Standard: ISO 18250-3 Figure C.3
- Product Type: Reference connector
- Test Sample: Cross-port reservoir connector / reservoir delivery system connector
- Application: Enteral reservoir connector leakage and unscrewing-related testing
- Material: Stainless steel
- Typical Test Use: Positive pressure liquid leakage, subatmospheric pressure air leakage, stress cracking, resistance to separation from unscrewing and disconnection by unscrewing
- Configuration Note: The required leakage equipment, unscrewing fixture and sample connection method should be confirmed according to the selected ISO 18250-3 test item.
Product Overview
Role of the Figure C.3 Reference Connector in Leakage and Unscrewing Tests
The ISO 18250-3 Figure C.3 Reference Connector is used as a defined reference connector in test configurations involving cross-port reservoir connectors. During testing, the customer’s sample connector is assembled with the Figure C.3 reference connector so that the connection interface can be evaluated under the required leakage, stress cracking or unscrewing-related conditions.
This product should not be treated as a general dimensional gauge only. It is part of a functional connector test setup where the mating condition, sealing performance and controlled disconnection behavior may affect the final evaluation result. The correct test fixture and connection method should therefore be confirmed before quotation.
KINGPO supplies the Figure C.3 reference connector as a precision-machined stainless steel component for ISO 18250-3 related connector testing. Depending on the selected test item, it may be used together with leakage test equipment, stress cracking test preparation accessories or unscrewing-related fixtures.
What This ISO 18250-3 Figure C.3 Connector Is Used For
The Figure C.3 reference connector is mainly used for test setups where a cross-port reservoir connector needs to be evaluated under leakage or unscrewing-related performance requirements. It provides a defined reference interface for checking whether the sample connector can maintain the required connection performance during laboratory verification.
Typical applications include:
- Cross-port reservoir connector verification
- Positive pressure liquid leakage test setup
- Subatmospheric pressure air leakage test setup
- Stress cracking related test preparation
- Resistance to separation from unscrewing
- Disconnection by unscrewing test setup
- Enteral reservoir connector product validation
- Laboratory quality control and pre-compliance checking
The exact test method, medium, pressure condition, unscrewing direction and fixture arrangement should be confirmed according to the applicable ISO 18250-3 test requirement.

Leakage and Unscrewing Test Setup Notes
Figure C.3 is normally used as part of a connector performance test setup rather than as a standalone test instrument. For leakage-related testing, the pressure source, test medium, sealing condition and connection method should be reviewed together with the sample structure.
For unscrewing-related tests, the fixture arrangement is important because the result may be affected by mating alignment, applied rotation, holding method and connector condition before testing. If the project involves both leakage and disconnection evaluation, the customer should confirm whether one reference connector is sufficient or whether additional accessories are required for different test steps.
Before quotation, it is helpful to confirm:
- Required ISO 18250-3 figure number
- Sample connector structure
- Intended test item
- Leakage medium and pressure condition, if applicable
- Unscrewing or disconnection test requirement
- Whether only the reference connector is needed
- Whether matching leakage or fixture equipment is required
- Documentation requirements for inspection or material information
Configuration and Documentation Notes
The Figure C.3 reference connector is made from stainless steel and intended for repeated laboratory handling when properly used, cleaned and stored. Because ISO 18250-3 connector testing may involve different leakage, stress cracking and unscrewing-related methods, the connector should be selected together with the required test item and sample structure.
Documentation requirements can be discussed before order. Depending on the project scope, dimensional inspection records, material information or other supporting documents may be prepared according to the agreed supply requirements.
Technical Features
| Item | Description |
|---|---|
| Standard Reference | ISO 18250-3 Figure C.3 |
| Connector Type | Reference connector |
| Typical Test Sample | Cross-port reservoir connector / reservoir delivery system connector |
| Main Application | Enteral reservoir connector leakage and unscrewing-related testing |
| Material | Stainless steel |
| Typical Test Setup | Leakage, stress cracking, unscrewing resistance and disconnection-by-unscrewing configurations |
| Supply Form | Single reference connector or part of an ISO 18250-3 connector configuration |
| Documentation | Dimensional or material documentation can be discussed before order |
Technical Inquiry & Expert Support
ISO 18250-3 connector testing may vary according to the sample structure, selected test item and required fixture arrangement. KINGPO supports configuration review for Figure C.3 reference connector applications, including leakage test setup considerations, unscrewing-related fixture selection and documentation requirements.
For projects involving cross-port reservoir connector verification, our team can assist in confirming the suitable ISO 18250-3 reference connector configuration before quotation.
Typical Users
This reference connector is suitable for:
- Medical device manufacturers developing reservoir delivery system connectors
- Enteral reservoir connector and accessory manufacturers
- Third-party medical device testing laboratories
- Product validation and quality control departments
- R&D teams evaluating connector sealing and disconnection behavior
- Laboratories requiring ISO 18250-3 related reference connectors and test fixtures
Related KINGPO ISO 18250 Test Equipment
| Related Product | When to Use |
| ISO 18250-3 Reference Connectors Selection Guide | For complete ISO 18250-3 Figure C.1 to C.6 reference connector selection, test purpose comparison and configuration guidance |
| ISO 18250-3 Figure C.4 Cross Reference Connector | For axial load separation and overriding resistance test configurations |
| ISO 18250-3 Figure C.5 Male Reference Connector | For test setups requiring a defined male reference connector |
| ISO 18250-3 Figure C.6 Female Reference Connector | For test setups requiring a defined female reference connector |
| ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector | For related cross-port reservoir connector test configurations |
| ISO 18250-1 Subatmospheric Pressure Air Leakage Tester | For air leakage testing where the selected ISO 18250 configuration requires leakage equipment |