ISO 18250-3 Figure C.5 male reference connector made of stainless steel for female enteral reservoir connector testing
Top detail of ISO 18250-3 Figure C.5 male reference connector showing mating surface and screw positions
Side view of ISO 18250-3 Figure C.5 male reference connector for female enteral reservoir connector testing
ISO 18250-3 Figure C.5 male reference connector made of stainless steel for female enteral reservoir connector testing
Top detail of ISO 18250-3 Figure C.5 male reference connector showing mating surface and screw positions
Side view of ISO 18250-3 Figure C.5 male reference connector for female enteral reservoir connector testing

ISO 18250-3 Figure C.5 Male Reference Connector

The ISO 18250-3 Figure C.5 Male Reference Connector is a stainless steel reference connector used for testing female enteral reservoir connectors in reservoir delivery system applications. It is designed for laboratory test setups where the connector interface needs to be evaluated for leakage, separation resistance, unscrewing resistance and overriding performance according to the selected ISO 18250-3 requirements.

  • Applicable Standard: ISO 18250-3 Figure C.5
  • Product Type: Male reference connector
  • Test Sample: Female enteral reservoir connector
  • Application: Enteral reservoir delivery system connector testing
  • Material: Stainless steel
  • Typical Test Use: Leakage, stress cracking, axial load separation, unscrewing separation and overriding related test setups
  • Quotation Note: Please confirm the required ISO 18250-3 figure number, sample connector type, test items and whether matching leakage or mechanical test equipment is required.

Product Overview

Role of the Figure C.5 Male Reference Connector in Testing

The ISO 18250-3 Figure C.5 Male Reference Connector is used as a standard mating connector when testing female enteral reservoir connectors. During the test setup, the reference connector is connected with the customer’s sample connector so that the interface can be evaluated under the required leakage or mechanical performance conditions.

Unlike a general dimensional gauge, this reference connector is part of a functional connector test setup. It helps laboratories, medical device manufacturers and quality verification teams check whether the tested female enteral reservoir connector can maintain proper connection performance under the selected ISO 18250-3 test requirements.

KINGPO supplies the Figure C.5 male reference connector as a precision-machined stainless steel component for ISO 18250-3 related enteral reservoir connector testing. The required test method, matching fixture and documentation should be confirmed before quotation.

What This ISO 18250-3 Figure C.5 Connector Is Used For

The Figure C.5 male reference connector is mainly used to test female enteral reservoir connectors. It is suitable for test setups where the sample connector must be assembled with a defined male reference connector before leakage or mechanical resistance evaluation.

Typical applications include:

  • Female enteral reservoir connector verification
  • Reservoir delivery system connector interface testing
  • Positive pressure liquid leakage test setup
  • Subatmospheric pressure air leakage test setup
  • Stress cracking related test preparation
  • Resistance to separation from axial load
  • Resistance to separation from unscrewing
  • Resistance to overriding test setup

The exact test procedure and acceptance criteria should be confirmed according to the applicable ISO 18250-3 clause and the customer’s product type.

ISO 18250-3 Figure C.5 male reference connector technical drawing for female enteral reservoir connector testing

Testing Setup Notes

This reference connector is normally not used alone. Depending on the required test item, it may need to be used together with leakage testing equipment, force application fixtures, torque fixtures or other ISO 18250 related test accessories.

For leakage testing, the customer should confirm whether the test requires positive pressure liquid leakage or subatmospheric pressure air leakage. For mechanical testing, the customer should confirm whether the requirement is related to axial separation, unscrewing separation or overriding resistance.

Before quotation, it is helpful to provide:

  • Required standard and edition
  • Required figure number, such as Figure C.5
  • Sample connector type and drawing if available
  • Required test items
  • Whether only the reference connector is needed
  • Whether a complete test setup is required
  • Whether dimensional inspection or material documentation is required

Configuration and Documentation Notes

The ISO 18250-3 Figure C.5 Male Reference Connector is made from stainless steel and manufactured according to the specified figure requirement. It is suitable for repeated laboratory use when properly handled, cleaned and stored.

Available documentation may be discussed before order, including dimensional inspection records, material information or other project-specific documents. KINGPO does not recommend assuming that a reference connector alone can complete all ISO 18250-3 tests. The required auxiliary equipment should be selected according to the exact test item.

If the customer is not sure whether Figure C.5 is the correct connector, please provide the sample connector type and intended test clause. KINGPO can help check whether Figure C.5 or another ISO 18250-3 reference connector is more suitable for the application.

Difference from Related ISO 18250-3 Connectors

Figure C.5 should be selected when the test sample is a female enteral reservoir connector and the test setup requires a male reference connector.

For related ISO 18250-3 test setups, other reference connectors may be required depending on the sample structure and test method. For example, a female reference connector may be needed when testing the corresponding male connector interface. Cross-port or other reservoir connector structures may require different ISO 18250-3 reference connector figures.

To avoid ordering the wrong tool, customers should confirm the required figure number and the mating direction before purchase.

Technical Features

Item Description
Standard Reference ISO 18250-3 Figure C.5
Connector Type Male reference connector
Test Sample Female enteral reservoir connector
Main Application Enteral reservoir delivery system connector testing
Material Stainless steel
Test Setup Use Leakage, separation, unscrewing and overriding related test setups
Supply Form Single reference connector or part of ISO 18250-3 connector configuration, depending on project requirements
Documentation Dimensional or material documentation can be discussed before order

Technical Inquiry & Expert Support

ISO 18250-3 connector test setups may vary according to the required figure number, mating connector structure and selected performance test. KINGPO supports configuration review for Figure C.5 male reference connector applications, including matching connector selection, leakage test setup considerations and documentation requirements.

For projects involving enteral reservoir connector verification, our team can assist in confirming the suitable reference connector configuration before quotation.

Typical Users

This reference connector is suitable for:

  • Medical device manufacturers developing enteral reservoir connectors
  • Third-party medical device testing laboratories
  • Quality control departments for connector verification
  • R&D teams validating new reservoir delivery system designs
  • Regulatory or pre-compliance testing projects requiring ISO 18250-3 related test tools

Related KINGPO ISO 18250 Test Equipment

Related Product When to Use
ISO 18250-3 Figure C.6 Female Reference Connector For test setups requiring the corresponding female reference connector
ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector For cross-port reservoir connector related test configurations
ISO 18250-3 Figure C.3 Reference Connector For ISO 18250-3 reservoir connector test setups requiring Figure C.3
ISO 18250-3 Figure C.4 Cross Reference Connector For related cross reference connector test configurations
ISO 18250-1 Subatmospheric Pressure Air Leakage Tester For air leakage testing when the selected test method requires matching leakage equipment
ISO 18250-3 Reference Connectors Selection Guide For complete ISO 18250-3 Figure C.1 to C.6 reference connector selection, test purpose comparison and configuration guidance

ISO 18250-3 Figure C.5 Male Reference Connector

FAQ

Is ISO 18250-3 Figure C.5 a male or female reference connector?
ISO 18250-3 Figure C.5 is a male reference connector. It is normally selected when the test sample is a female enteral reservoir connector and the test setup requires a defined male mating connector for leakage or mechanical performance evaluation.
What type of sample is tested with the Figure C.5 male reference connector?
This reference connector is used with female enteral reservoir connectors used in reservoir delivery system applications. Before ordering, the customer should confirm the sample connector structure, the required ISO 18250-3 figure number and the intended test item.
Is this product only a dimensional gauge?
No. It should not be treated only as a simple dimensional gauge. The Figure C.5 male reference connector is a standard mating connector used as part of a functional test setup. Depending on the test requirement, it may be used together with leakage testing equipment, force fixtures or torque-related fixtures.
Can the Figure C.5 connector be used for leakage testing?
Yes, it can be used in leakage-related test setups when the applicable ISO 18250-3 test method requires the Figure C.5 male reference connector. The pressure condition, medium, connection method and matching test equipment should be confirmed according to the selected test clause.
Do I need additional equipment to perform ISO 18250-3 tests?
In many cases, yes. The reference connector itself is only one part of the test setup. Leakage tests may require air or liquid leakage testing equipment, while separation, unscrewing or overriding tests may require force or torque application fixtures. KINGPO can help confirm the required configuration based on the customer’s test items.
Can KINGPO provide this connector as part of a complete ISO 18250-3 connector set?
Yes. The Figure C.5 male reference connector can be discussed as a single item or as part of a broader ISO 18250-3 reference connector configuration. Customers should provide the required figure numbers, sample connector types and test items before quotation.
What information should be provided before quotation?
Please provide the required standard and edition, figure number, sample connector type, intended test items and whether you need only the reference connector or a complete test setup. If available, a sample drawing or photo can help reduce the risk of selecting the wrong reference connector.
Can KINGPO provide inspection or documentation for the connector?
Documentation requirements should be confirmed before order. Depending on the project, dimensional inspection records, material information or other supporting documents may be discussed. KINGPO recommends confirming documentation requirements before production or shipment rather than after delivery.

Related Products

Related News

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.