UL 1017 Figure 7.1 Checkerboard Step and Base for floor cleaning appliance test setup
UL 1017 Section 7.2.8 Test Frame with polished composition-tile floor for flooul-1017-figure-7-1-checkerboard-step-and-baser cleaning appliance testing
UL 1017 Test Fixture Set with test frame and checkerboard step base in laboratory test setup
Angled view of UL 1017 Test Frame and Checkerboard Step Base for floor cleaning appliance evaluation
UL 1017 floor cleaning appliance test fixture set for vacuum cleaner and floor sweeper test setup
UL 1017 Figure 7.1 Checkerboard Step and Base for floor cleaning appliance test setup
UL 1017 Section 7.2.8 Test Frame with polished composition-tile floor for flooul-1017-figure-7-1-checkerboard-step-and-baser cleaning appliance testing
UL 1017 Test Fixture Set with test frame and checkerboard step base in laboratory test setup
Angled view of UL 1017 Test Frame and Checkerboard Step Base for floor cleaning appliance evaluation
UL 1017 floor cleaning appliance test fixture set for vacuum cleaner and floor sweeper test setup

UL 1017 Test Fixture Set with Test Frame and Checkerboard Step Base

The UL 1017 Test Fixture Set includes a test frame and a checkerboard step and base for floor cleaning appliance test setups. The test frame is related to UL 1017 11th Edition Section 7.2.8, while the checkerboard step and base is related to Section 7.2.18 and Figure 7.1.

This fixture set is designed for laboratories and manufacturers that need standard-related physical test fixtures for vacuum cleaners, floor sweepers, household floor finishing machines and related floor cleaning appliances.

  • Applicable standard: UL 1017 11th Edition
  • Product type: Mechanical test fixture set
  • Included fixtures: Test Frame; Checkerboard Step and Base
  • Fixture 1: Test Frame, related to UL 1017 Section 7.2.8
  • Fixture 2: Checkerboard Step and Base, related to UL 1017 Section 7.2.18, Figure 7.1
  • Frame size: 1500 × 1500 × 50 mm
  • Frame surface: Polished composition-tile floor
  • Test object: Vacuum cleaners, floor sweepers, household floor finishing machines and related floor cleaning appliances
  • Application: Laboratory test setup, product verification, quality control and certification preparation
  • Supply option: Complete set or separate fixture configuration according to customer requirement

UL 1017 Test Fixture Set Overview

The UL 1017 Test Fixture Set provides standard-related physical test conditions for floor cleaning appliance evaluation. The test frame offers a defined polished composition-tile floor surface as required by UL 1017 Section 7.2.8, while the checkerboard step and base supports the test configuration specified in UL 1017 Section 7.2.18 and Figure 7.1.

These fixtures are passive mechanical setup accessories. They do not perform automatic measurement, force control or data recording. Their main function is to help users establish consistent physical test conditions during product verification and laboratory testing.

The test frame and checkerboard step base can be supplied together as a complete fixture set or reviewed separately according to the customer’s UL 1017 test clause, laboratory layout and certification preparation requirements.

Technical Parameters

Parameter Specification Remark or Notes
Applicable Standard UL 1017 11th Edition Floor cleaning appliance safety standard
Product Type Mechanical test fixture set Physical setup accessory
Included Fixture 1 Test Frame Related to Section 7.2.8
Included Fixture 2 Checkerboard Step and Base Related to Section 7.2.18, Figure 7.1
Frame Dimensions 1500 × 1500 × 50 mm Including polished composition-tile floor
Frame Surface Polished composition-tile floor Standard-related floor test surface
Test Object Vacuum cleaners, floor sweepers, household floor finishing machines Floor cleaning appliances
Supply Mode Complete set or individual fixtures According to customer requirement
Documentation Dimensional inspection record available Upon request

Testing Principle

The UL 1017 Test Fixture Set is used to establish defined physical test conditions for floor cleaning appliance evaluation. The test frame provides a controlled floor surface area, while the checkerboard step and base creates the specific step configuration required by UL 1017 Figure 7.1.

During testing, the appliance is positioned or operated on the required fixture according to the applicable UL 1017 clause. The fixture helps keep the floor surface, step structure and setup condition consistent, so that product performance or safety behavior can be evaluated under repeatable laboratory conditions.

Because the fixture set is passive, test results depend on the appliance sample, operating method, fixture condition, applicable clause and laboratory judgment criteria.

Common Error Mitigation

To support repeatable test setup, users should confirm the applicable UL 1017 edition and specific test clause before ordering or using the fixture set.

The polished composition-tile floor and checkerboard step base should be clean, stable and free from visible damage or contamination. The frame should be placed on a level surface before the appliance is positioned for testing.

Operators should follow the exact setup, positioning and operating instructions defined in the relevant UL 1017 section. The fixture set should not be used as a universal floor platform or general-purpose test bench outside the specified test condition.

Applications and Use Cases

The UL 1017 Test Fixture Set is used by manufacturers and laboratories involved in floor cleaning appliance testing. It supports test setup for vacuum cleaners, floor sweepers, household floor finishing machines and related products according to UL 1017.

Typical applications include product development verification, internal quality control, laboratory pre-compliance testing, preparation for third-party certification and repeatable physical test setup across different floor cleaning appliance projects.

Key Advantages

Customized UL 1017 test frame and checkerboard step and base fixture before shipment.

  1. Complete fixture configuration:
    Includes both the UL 1017 Section 7.2.8 test frame and the Section 7.2.18 Figure 7.1 checkerboard step and base.
  2. Defined physical test surface:
    The test frame provides a 1500 × 1500 × 50 mm structure with polished composition-tile floor for standard-related floor test setup.
  3. Repeatable laboratory setup:
    Helps laboratories maintain consistent floor surface and step/base conditions during product verification and pre-compliance testing.
  4. Flexible supply option:
    The test frame and checkerboard step base can be supplied as a complete set or as individual fixtures according to the customer’s test plan.
  5. Documentation support:
    Dimensional inspection records or related quality documents can be provided according to order requirements.

Compliance and Test Setup Support

The UL 1017 Test Fixture Set is designed to support physical test setups related to UL 1017 11th Edition, especially Section 7.2.8 and Section 7.2.18 Figure 7.1.

It is a mechanical fixture set for preparing test conditions and does not replace full product compliance assessment, certification review or final laboratory judgment. Users should confirm the applicable standard edition, test clause, sample operation method and acceptance criteria with the responsible laboratory or certification body.

Dimensional Integrity and Validation

  • The fixtures should be periodically inspected for dimensional accuracy, surface condition and structural stability. Any visible damage, deformation, contamination or abnormal wear on the polished floor or checkerboard surface should be checked before further use.
  • Proper storage, handling and cleaning help maintain fixture condition and test repeatability over time. Dimensional inspection records or factory verification documents can be supplied according to customer requirements.
PDF

Download Product Catalog

UL 1017 Test Fixture Set Product Catalog

Product catalog for laboratory test fixtures used for UL 1017 related compliance and safety testing applications.

Technical Inquiry & Expert Support

KingPo supplies the UL 1017 Test Fixture Set for floor cleaning appliance testing. Our engineering team can help review whether you need the complete fixture set or individual components based on your UL 1017 test clause and laboratory setup.

Please Provide the Following Information

  • Applicable standard: UL 1017 11th Edition or internal test procedure
  • Required fixture: Test Frame, Checkerboard Step and Base, or complete fixture set
  • Related clause: Section 7.2.8, Section 7.2.18, Figure 7.1 or other clause requirement
  • Test object: Vacuum cleaner, floor sweeper, household floor finishing machine or related appliance
  • Fixture requirement: Frame size, floor surface, checkerboard step base configuration and drawing reference
  • Documentation: Inspection record, dimensional report or other quality document
  • Customization needs: Material, surface, marking, packaging or special laboratory layout requirement

Based on this information, KingPo can provide configuration suggestions, documentation support and quotation for your UL 1017 test fixture project.

UL 1017 Test Fixture Set Detail Display

UL 1017 Test Fixture Set FAQs

What is the UL 1017 Test Fixture Set used for?
The UL 1017 Test Fixture Set is used to prepare physical test setups for floor cleaning appliance evaluation. It includes a test frame and a checkerboard step and base for testing vacuum cleaners, floor sweepers, household floor finishing machines and related appliances according to the applicable UL 1017 test clause.
What fixtures are included in this set?
The set includes two standard-related fixtures: a test frame related to UL 1017 Section 7.2.8 and a checkerboard step and base related to UL 1017 Section 7.2.18 and Figure 7.1. Customers can order the complete fixture set or confirm individual fixture requirements before production.
What is the UL 1017 test frame used for?
The UL 1017 test frame provides a defined floor surface for floor cleaning appliance test setup. According to the provided configuration, it includes a polished composition-tile floor and supports Section 7.2.8 related testing. Final use should follow the applicable UL 1017 edition and laboratory procedure.
What is the checkerboard step and base used for?
The checkerboard step and base is used for UL 1017 Section 7.2.18 and Figure 7.1 related test setup. It provides the required physical step/base configuration for floor cleaning appliance evaluation. The final setup should be confirmed according to the standard clause and customer test method.
Which products can be tested with this fixture set?
This fixture set is suitable for floor cleaning appliances covered by UL 1017 related test setups, including vacuum cleaners, floor sweepers and household floor finishing machines. It may also support related internal laboratory evaluations when the customer’s test procedure requires similar physical floor or step fixtures.
Does the UL 1017 Test Fixture Set perform automatic testing?
No. This product is a passive mechanical test fixture set. It does not perform electrical measurement, force measurement, motion control or automatic data recording. Its purpose is to provide the required physical test surface and step/base configuration for repeatable UL 1017 laboratory test setup.
Can the test frame and checkerboard step base be ordered separately?
Yes. The test frame and checkerboard step and base can be supplied as a complete set or as individual fixtures. Before ordering, customers should confirm the applicable UL 1017 clause, required fixture type, drawing reference, appliance type and documentation requirements.
What should be confirmed before ordering this fixture set?
Customers should confirm the applicable UL 1017 edition, test clause, required fixture configuration, test object and documentation needs. For certification preparation, it is also recommended to confirm the fixture requirement with the responsible laboratory or certification body before finalizing the order.
What documentation can be provided with the fixture set?
Available documentation may include dimensional inspection records, factory verification records or related quality documents according to the order requirement. If the fixture set is used for third-party laboratory testing or certification preparation, the required documentation package should be confirmed before production.
How should the UL 1017 test fixtures be maintained?
The fixtures should be kept clean, stable and protected from impact, deformation, contamination and abnormal wear. The polished composition-tile floor and checkerboard step base should be inspected before use. If visible damage or surface deterioration is found, the fixture should be checked before further testing.

Related Products

Related News

KingPo has completed the delivery of customized UL 1017 test fixtures to Intertek for the testing of vacuum cleaners, blower […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.