UL 1017 Test Fixture Set with Test Frame and Checkerboard Step Base
The UL 1017 Test Fixture Set includes a test frame and a checkerboard step and base for floor cleaning appliance test setups. The test frame is related to UL 1017 11th Edition Section 7.2.8, while the checkerboard step and base is related to Section 7.2.18 and Figure 7.1.
This fixture set is designed for laboratories and manufacturers that need standard-related physical test fixtures for vacuum cleaners, floor sweepers, household floor finishing machines and related floor cleaning appliances.
- Applicable standard: UL 1017 11th Edition
- Product type: Mechanical test fixture set
- Included fixtures: Test Frame; Checkerboard Step and Base
- Fixture 1: Test Frame, related to UL 1017 Section 7.2.8
- Fixture 2: Checkerboard Step and Base, related to UL 1017 Section 7.2.18, Figure 7.1
- Frame size: 1500 × 1500 × 50 mm
- Frame surface: Polished composition-tile floor
- Test object: Vacuum cleaners, floor sweepers, household floor finishing machines and related floor cleaning appliances
- Application: Laboratory test setup, product verification, quality control and certification preparation
- Supply option: Complete set or separate fixture configuration according to customer requirement
UL 1017 Test Fixture Set Overview
The UL 1017 Test Fixture Set provides standard-related physical test conditions for floor cleaning appliance evaluation. The test frame offers a defined polished composition-tile floor surface as required by UL 1017 Section 7.2.8, while the checkerboard step and base supports the test configuration specified in UL 1017 Section 7.2.18 and Figure 7.1.
These fixtures are passive mechanical setup accessories. They do not perform automatic measurement, force control or data recording. Their main function is to help users establish consistent physical test conditions during product verification and laboratory testing.
The test frame and checkerboard step base can be supplied together as a complete fixture set or reviewed separately according to the customer’s UL 1017 test clause, laboratory layout and certification preparation requirements.
Technical Parameters
| Parameter | Specification | Remark or Notes |
|---|---|---|
| Applicable Standard | UL 1017 11th Edition | Floor cleaning appliance safety standard |
| Product Type | Mechanical test fixture set | Physical setup accessory |
| Included Fixture 1 | Test Frame | Related to Section 7.2.8 |
| Included Fixture 2 | Checkerboard Step and Base | Related to Section 7.2.18, Figure 7.1 |
| Frame Dimensions | 1500 × 1500 × 50 mm | Including polished composition-tile floor |
| Frame Surface | Polished composition-tile floor | Standard-related floor test surface |
| Test Object | Vacuum cleaners, floor sweepers, household floor finishing machines | Floor cleaning appliances |
| Supply Mode | Complete set or individual fixtures | According to customer requirement |
| Documentation | Dimensional inspection record available | Upon request |
Testing Principle
The UL 1017 Test Fixture Set is used to establish defined physical test conditions for floor cleaning appliance evaluation. The test frame provides a controlled floor surface area, while the checkerboard step and base creates the specific step configuration required by UL 1017 Figure 7.1.
During testing, the appliance is positioned or operated on the required fixture according to the applicable UL 1017 clause. The fixture helps keep the floor surface, step structure and setup condition consistent, so that product performance or safety behavior can be evaluated under repeatable laboratory conditions.
Because the fixture set is passive, test results depend on the appliance sample, operating method, fixture condition, applicable clause and laboratory judgment criteria.
Common Error Mitigation
To support repeatable test setup, users should confirm the applicable UL 1017 edition and specific test clause before ordering or using the fixture set.
The polished composition-tile floor and checkerboard step base should be clean, stable and free from visible damage or contamination. The frame should be placed on a level surface before the appliance is positioned for testing.
Operators should follow the exact setup, positioning and operating instructions defined in the relevant UL 1017 section. The fixture set should not be used as a universal floor platform or general-purpose test bench outside the specified test condition.
Applications and Use Cases
The UL 1017 Test Fixture Set is used by manufacturers and laboratories involved in floor cleaning appliance testing. It supports test setup for vacuum cleaners, floor sweepers, household floor finishing machines and related products according to UL 1017.
Typical applications include product development verification, internal quality control, laboratory pre-compliance testing, preparation for third-party certification and repeatable physical test setup across different floor cleaning appliance projects.
Key Advantages

- Complete fixture configuration:
Includes both the UL 1017 Section 7.2.8 test frame and the Section 7.2.18 Figure 7.1 checkerboard step and base. - Defined physical test surface:
The test frame provides a 1500 × 1500 × 50 mm structure with polished composition-tile floor for standard-related floor test setup. - Repeatable laboratory setup:
Helps laboratories maintain consistent floor surface and step/base conditions during product verification and pre-compliance testing. - Flexible supply option:
The test frame and checkerboard step base can be supplied as a complete set or as individual fixtures according to the customer’s test plan. - Documentation support:
Dimensional inspection records or related quality documents can be provided according to order requirements.
Compliance and Test Setup Support
The UL 1017 Test Fixture Set is designed to support physical test setups related to UL 1017 11th Edition, especially Section 7.2.8 and Section 7.2.18 Figure 7.1.
It is a mechanical fixture set for preparing test conditions and does not replace full product compliance assessment, certification review or final laboratory judgment. Users should confirm the applicable standard edition, test clause, sample operation method and acceptance criteria with the responsible laboratory or certification body.
Dimensional Integrity and Validation
- The fixtures should be periodically inspected for dimensional accuracy, surface condition and structural stability. Any visible damage, deformation, contamination or abnormal wear on the polished floor or checkerboard surface should be checked before further use.
- Proper storage, handling and cleaning help maintain fixture condition and test repeatability over time. Dimensional inspection records or factory verification documents can be supplied according to customer requirements.
Technical Inquiry & Expert Support
KingPo supplies the UL 1017 Test Fixture Set for floor cleaning appliance testing. Our engineering team can help review whether you need the complete fixture set or individual components based on your UL 1017 test clause and laboratory setup.
Please Provide the Following Information
- Applicable standard: UL 1017 11th Edition or internal test procedure
- Required fixture: Test Frame, Checkerboard Step and Base, or complete fixture set
- Related clause: Section 7.2.8, Section 7.2.18, Figure 7.1 or other clause requirement
- Test object: Vacuum cleaner, floor sweeper, household floor finishing machine or related appliance
- Fixture requirement: Frame size, floor surface, checkerboard step base configuration and drawing reference
- Documentation: Inspection record, dimensional report or other quality document
- Customization needs: Material, surface, marking, packaging or special laboratory layout requirement
Based on this information, KingPo can provide configuration suggestions, documentation support and quotation for your UL 1017 test fixture project.
UL 1017 Test Fixture Set Detail Display
UL 1017 Test Fixture Set FAQs
Related Products
Related News
KingPo has completed the delivery of customized UL 1017 test fixtures to Intertek for the testing of vacuum cleaners, blower […]