ISO 5356-1 Figure A.1 Gauge | HME Patient Port Connector Testing
The ISO 5356-1 Figure A.1 Gauge is a precision reference gauge designed for dimensional verification of HME patient port conical connectors in anaesthetic and respiratory equipment.
- Standard Compliance: ISO 5356-1 Figure A.1 โ exact gauge for HME patient port connector testing
- Material: High-hardness steel with HRC 58-62
- Test Functions: Dimensional verification of cones and sockets for leakage prevention and secure connection
- Application: Testing of 15 mm and 22 mm conical connectors used with HMEs and breathing systems
- Precision: Manufactured to tight tolerances for repeatable and traceable results
- MOQ: 1
- Delivery Period: 7 working days
ISO 5356-1 Figure A.1 Gauge Description
ISO 5356-1 Medical Gauge For Testing HME Patient Port Connector
The ISO 5356-1 Figure A.1 Gauge | HME Patient Port Connector Testing is a precision reference gauge manufactured by KingPo. It is specifically designed to verify the dimensional accuracy and interchangeability of HME patient port conical connectors in anaesthetic and respiratory equipment, in full accordance with ISO 5356-1 Figure A.1.
Technical Parameters
| Parameter | Specification | Remark / Notes |
|---|---|---|
| Standard | ISO 5356-1 Figure A.1 | Reference gauge for HME patient port conical connectors |
| Material | Hardened steel | High wear resistance and long-term dimensional stability |
| Hardness | HRC 58-62 | Ensures durability under repeated use in laboratory testing |
| Gauge Type | Plug / ring reference gauge | Verifies cone and socket dimensions for secure, leak-free connections |
| Application | 15 mm and 22 mm conical connectors | Used with HMEs and breathing systems in anaesthetic and respiratory equipment |
| Certification | ISO 17025 traceable | Supports laboratory accreditation and audit requirements |
The gauge is precision-machined from high-hardness steel (HRC 58-62) to achieve exact dimensional tolerances as specified in ISO 5356-1 Figure A.1. Critical contact surfaces are ground and polished to minimize friction variability while maintaining consistent fit characteristics.
The robust construction prevents deformation even after thousands of test cycles, ensuring repeatable verification of cone angle, diameter, and engagement length. All critical dimensions are controlled to guarantee reliable detection of non-compliant connectors that could lead to leakage or accidental disconnection.
Testing Principle
The gauge is mated with the HME patient port conical connector under controlled conditions to verify dimensional compliance. It checks cone and socket geometry to ensure secure, leak-free connections and proper interchangeability between components from different manufacturers, as required by ISO 5356-1.
Common Error Mitigation
To ensure repeatable and accurate results, always align the connector axially without lateral force and verify that the gauge is clean and free of debris before each test. Regular visual inspection and periodic recalibration help maintain measurement integrity and prevent false pass/fail outcomes.

Primary Use Cases & Business Value
The ISO 5356-1 Figure A.1 Gauge is used by medical device manufacturers and certification laboratories to verify dimensional accuracy and interchangeability of HME patient port connectors. It helps ensure patient safety by preventing leakage and accidental disconnection in critical breathing systems.
Industrial Applications & Lab Scenarios
- Respiratory device manufacturers โ dimensional verification of HME patient port connectors per ISO 5356-1
- Third-party certification laboratories โ traceable compliance testing of conical connectors
- R&D departments โ development and optimization of new HME and breathing system designs
- Quality control teams โ batch verification of conical connectors used in anaesthetic and respiratory equipment
- Regulatory compliance teams โ demonstration of interchangeability and safety requirements
Strategic Procurement Advantages & Global Support
- High-Efficiency Testing: Precision gauge enables fast, repeatable ISO 5356-1 Figure A.1 testing with minimal setup time.
- Certified Manufacturing: ISO 9001/14001/45001 and CE certified production with ISO 17025 traceability ensures laboratory-grade reliability.
- Reliability & Support: Each unit undergoes rigorous factory calibration in our Dongguan facility and is backed by a full one-year warranty, on-site installation guidance, and lifetime technical engineering support.
Compliance & Regulatory Assurance
This equipment is manufactured in full accordance with ISO 5356-1 Figure A.1 for testing HME patient port conical connectors. It provides a standardized, reproducible test method essential for demonstrating compliance with international requirements for dimensional accuracy, interchangeability and patient safety in anaesthetic and respiratory equipment.
For detailed information on test procedures, please refer to the latest edition of ISO 5356-1. Regular visual inspection and recalibration are recommended to maintain accuracy.
Technical Inquiry & Expert Support
KingPo provides validated ISO 5356-1 Figure A.1 gauges for HME patient port connector testing. Contact our medical engineering team for 1:1 dimensional configurations and setup support.
The Core Value We Deliver
- ISO 5356-1 Compliance: Exact replication of Figure A.1 geometry for conical connector testing.
- Optical Clarity & Durability: High-hardness steel (HRC 58-62) construction for long-term precision.
- Repeatable Results: Precision-machined to eliminate dimensional variance.
- Lab Ready: Seamless integration with standard HME and breathing system test setups.
- Fast Response: Get a tailored technical recommendation within 24 hours.
ISO 5356-1 Scope
This part of ISO 5356 specifies dimensional and gauging requirements for cones and sockets intended for connecting anaesthetic and respiratory equipment, e.g. in breathing systems, anaesthetic-gas scavenging systems and vaporizers.
This part of ISO 5356 gives requirements for the following conical connectors:
- – 8,5 mm size intended for use in paediatric breathing systems
- – 15 mm and 22 mm sizes intended for general use in breathing systems
- – 22 mm latching connectors (including performance requirements)
- – 23 mm size intended for use with vaporizers, but not for use in breathing systems
- – 30 mm size intended for the connection of a breathing system to an anaesthetic gas scavenging system.
This part of ISO 5356 does not specify the medical devices and accessories on which these connections are to be provided. Requirements for the application of conical connectors are not included in this part of ISO 5356, but are or will be given in the relevant International Standards for specific medical devices and accessories.
NOTE: Requirements for screw-threaded weight-bearing conical connectors are specified in ISO 5356-2.
15mm ringย gauge

15mm plug gauge

22mm ring gaugeย 
22mm plug gauge

Detail Display
ISO 5356-1 Figure A.1 Gauge FAQs
Related Products
Related News
How to Troubleshoot Common Faults in Water Pump Testing Equipment: Practical Operation Guide for ISO 9906 Compliance Introduction Operators […]
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
Abstract & Technical Summary Navigating Australia’s heavy-duty electrical landscape requires strict adherence to the AS/NZS 3123 standard, which governs polyphase […]
NE Contact Impedance Tester for Contact Resistance Accuracy NE Contact Impedance Tester In the world of electrical testing equipment, the […]
ISO 5356-1:2015 is the internationally recognized standard titled Anaesthetic and respiratory equipment โ Conical connectors โ Part 1: Cones and […]