Showing Slide 1 of 3
300W Battery Testing Machine For For Charging / Discharging / Voltage Testing
This 300W Battery Testing Machine efficiently performs charging, discharging, and voltage tests with high precision and reliability.
MOQ: 1
Price: To be quoted
Standard Packaging: safety carton pack or plywood box
Delivery Period: 35 working days
Payment Method: T/T
Supply Capacity: 3 sets per month
Products Categories
Get A Free Quote
Detail Information
| Place of Origin | China | Brand Name | KingPo |
| Certification | Iso9001 Ce | Model Number | BTS-60V5A |
| Constant Voltage Range: | 0.3V~60V | Current Output Range/channel: | 0.025A~5A |
| Power Output Range/channel: | 300W | Current Response Time: | Maximum Current Rising Time 20ms |
| Data Record Frequency: | 10Hz | Single Cycle Working Steps: | 254 |
| Highlight: | Battery Testing System, Battery Test Chamber, 300W Battery Testing Machine | ||
Technical Parameters
| BTS-60V5A Battery tester | ||||||||||||||||
| Model Number: | BTS- | 60 | V | 5 | A | Battery tester | Material code: | CT-4016 | -60V5A | – | NTA | – | P | |||
| items | Parameter | |||||||||||||||
| Input power | AC 380V ±10% / 60Hz | |||||||||||||||
| Input active power | 6278 | W | ||||||||||||||
| resolution ratio | AD:16bit;DA:16bit | |||||||||||||||
| Input impedance | ≥100kΩ | |||||||||||||||
| voltage | Constant voltage range | 0.3V~60V | ||||||||||||||
| Minimum discharge voltage | 3V | |||||||||||||||
| accuracy | ± 0.1% of FS | |||||||||||||||
| stability | ± 0.1% of FS | |||||||||||||||
| current | Output range/channel | 0.025A~5A | ||||||||||||||
| accuracy | ± 0.1% of FS | |||||||||||||||
| Constant voltage cut-off current | 0.01A | |||||||||||||||
| stability | ± 0.1% of FS | |||||||||||||||
| Power | Output range/channel | 300W | ||||||||||||||
| stability | ±0.2% of FS | |||||||||||||||
| time | Current response time | maximum current rising time20ms | ||||||||||||||
| working step time range | ≤(365*24)h/working step | |||||||||||||||
| Data record | Record data conditions | Minimum time interval:100ms | ||||||||||||||
| Minimum voltage interval:120mV | ||||||||||||||||
| Minimum current interval:10mA | ||||||||||||||||
| Record frequency | 10Hz | |||||||||||||||
| Charge | Charge mode | constant-current charge,constant-voltage charge,constant voltage and current charge | ||||||||||||||
| cut-off conditions | Voltage,current,relative time,capacity,-△V | |||||||||||||||
| discharge | Discharge mode | constant current discharge, constant watt discharge | ||||||||||||||
| cut-off conditions | Voltage,current,relative time,capacity,-△V | |||||||||||||||
| Impulse mode | Charge | Constant current,Constant power | ||||||||||||||
| Discharge | Constant current,Constant power | |||||||||||||||
| Minimum impulse width | 500ms | |||||||||||||||
| Number of pulses | one single pulse working step can support 32 different pulses | |||||||||||||||
| Continuous switch of charge and discharge | one pulse working step can continuously switch from charge to discharge | |||||||||||||||
| cut-off conditions | Voltage,relative time | |||||||||||||||
| DCIR test | Support customized picking up point to perform DCIR calculation | |||||||||||||||
| cycle | Loop test range | 1~65535 times | ||||||||||||||
| Single cycle working steps | 254 | |||||||||||||||
| Loop nest | Nested loop function,max 3 layers | |||||||||||||||
| Protection | ● Data Protection | |||||||||||||||
| ● off-line test | ||||||||||||||||
| ● security conditions can be set including voltage upper/lower limit,current upper/lower limit and delay time | ||||||||||||||||
| ●anti reverse connection | ||||||||||||||||
| IP Protection Class | IP20 | |||||||||||||||
| Channel feature | constant current and voltage source ;double closed-loop; | |||||||||||||||
| Channel control mode | independent | |||||||||||||||
| Current/voltage detection sampling | four-wire connection | |||||||||||||||
| noise | <85dB | |||||||||||||||
| data base | MySQL centralized management of test datas | |||||||||||||||
| upper computer communication mode | TCP/IP | |||||||||||||||
| Server disk Configuration | 500GB | |||||||||||||||
| Data output mode | EXCEL 2003,2010,TXT | |||||||||||||||
| Server operating system | Windows 7 | |||||||||||||||
| communication interface | ethernet | |||||||||||||||
| Working environment requirement | ||||||||||||||||
| item | parameter | |||||||||||||||
| working temp. range | 0℃~40℃(within25±10℃,ensured accuracy:precision drift0.005% of FS /℃) | |||||||||||||||
| Storage temp. range | -10℃~50℃ | |||||||||||||||
| Working environment relative humidity range | ≤70% RH(no water vapor condensation) | |||||||||||||||
| Storage environment relative humidity range | ≤80% RH(no water vapor condensation) | |||||||||||||||
| Clamp specification and size | ||||||||||||||||
| item | parameter | |||||||||||||||
| Clamp type | Polymer clamp | |||||||||||||||
| Pic | ![]() |
![]() |
![]() |
|||||||||||||
| Alligator clamp | Polymer clamp | cable feet clamp | ||||||||||||||
| Pictures are for reference only,real objects shall prevail.Choose one | ||||||||||||||||
| Cabinet size/unit(W*D*H)(mm) | 30U(24”),730*600*1520 | |||||||||||||||
| Equipment pic | Pictures are for reference only,real objects shall prevail. | |||||||||||||||
| Auxiliary channel | type | Temperature,voltage | ||||||||||||||
| Temp. range | -25℃~110℃ | |||||||||||||||
| Temp. range | ±1℃ | |||||||||||||||
| Temp. resolution ratio | 0.1℃ | |||||||||||||||
| Voltage range | -5V~5V | |||||||||||||||
| Voltage accuracy | ± 0.1% of FS | |||||||||||||||
| Available auxiliary temp.channel/channel | customized(248 channel at most) | |||||||||||||||
| Available auxiliary voltage channel/channel | customized(248 channel at most) | |||||||||||||||
| Protaction condition of Auxiliary channel | ● security conditions of Auxiliary channel can be set including temperature upper/lower limit,voltage upper/lower limit and delay time,voltage difference of single cell | |||||||||||||||
| Note:incompatible with battery that has protection plate with soft start function. | ||||||||||||||||
Get Free Quote of 300W Battery Testing Machine For For Charging / Discharging / Voltage Testing
Related Products
Related News
An 8K Signal Generator streamlines display calibration, ensuring precise results, broad compatibility, and compliance with UHD standards for modern displays.
Enhancing Electrical Safety with IEC 60309 Compliance Gauges 3 I see electrical safety as a top priority in every industrial […]