ISO 5151 Air Enthalpy Calorimeter 60K BTU – Dual Code Computer Control System for Air Conditioner Performance Testing
Dual Code Air Enthalpy Calorimeter Test Chamber with Indoor and Outdoor Sections for Air Conditioner Capacity Testing
ISO 5151 Air Enthalpy Calorimeter 60K BTU – Dual Code Computer Control System for Air Conditioner Performance Testing
Dual Code Air Enthalpy Calorimeter Test Chamber with Indoor and Outdoor Sections for Air Conditioner Capacity Testing

ISO 5151 60K BTU Air Enthalpy Calorimeter for Air Conditioner Testing

The ISO 5151 Air Enthalpy Calorimeter is a professional HVAC performance test system designed for measuring the cooling capacity, heating capacity, airflow rate, electrical input and energy efficiency of air conditioners under controlled laboratory conditions.

The system uses indoor and outdoor environmental chambers, airflow measurement modules, temperature and humidity sensors, electrical parameter monitoring and computer-based data acquisition to calculate air-side enthalpy difference and determine air conditioner performance according to ISO 5151-related test methods.

  • Applicable standard: ISO 5151
  • Test object: Non-ducted air conditioners and air-to-air heat pump products
  • Capacity range: 6,000–60,000 BTU/h
  • Test configuration: Dual-station air enthalpy calorimeter system
  • Indoor airflow range: 300–4,000 m³/h
  • Outdoor airflow range: 200–2,000 m³/h
  • Measured parameters: Temperature, humidity, airflow, voltage, current, power, frequency and power factor
  • Applications: HVAC laboratories, air conditioner manufacturers, certification testing institutions and R&D centers
  • MOQ: 1 set
  • Delivery time: Around 3 months, depending on final configuration

Air Enthalpy Calorimeter Description

ISO 5151 60K BTU Dual-Station Air Enthalpy Calorimeter for Air Conditioner Performance Testing

The ISO 5151 Air Enthalpy Calorimeter is a professional HVAC performance test system designed to evaluate the cooling capacity, heating capacity, airflow rate, electrical input and energy efficiency of air conditioners under controlled laboratory conditions.

By measuring air temperature, humidity, airflow rate and electrical parameters, the system calculates the air-side enthalpy difference and determines the actual cooling or heating performance of the unit under test. It provides a repeatable laboratory platform for performance rating, product development, certification preparation and quality verification.

The system is suitable for ISO 5151-related testing of non-ducted air conditioners and air-to-air heat pump products, including split units, window units, freestanding units, cassette-type units and inverter air conditioners. For other HVAC product types, the final chamber configuration and test method should be reviewed according to the applicable standard and customer requirements.

System Configuration and Measurement Capability

The calorimeter combines indoor and outdoor environmental chambers, airflow measurement devices, temperature and humidity sensors, electrical parameter monitoring and computer-based control software to form a complete HVAC performance test platform.

Indoor and Outdoor Environmental Chambers

The system includes two controlled environmental chambers:

  • Indoor Chamber
    Simulates indoor air conditions for cooling and heating capacity evaluation.
  • Outdoor Chamber
    Reproduces outdoor ambient conditions required for standard air conditioner performance testing.

This configuration allows the test unit to operate under controlled indoor and outdoor conditions, helping laboratories obtain stable and repeatable performance data.

Dual-Station Test Design

The system is designed with dual-station testing capability to improve laboratory efficiency.

It can support:

  • Two single-phase air conditioners up to 30,000 BTU/h tested independently
  • One air conditioner up to 60,000 BTU/h tested using a single station

This design is suitable for laboratories that need to test different residential air conditioner capacities while maintaining flexible use of chamber resources.

Airflow Measurement

The system integrates airflow measurement modules for both indoor and outdoor test chambers.

Chamber Airflow Range
Indoor Chamber 300–4,000 m³/h
Outdoor Chamber 200–2,000 m³/h

Airflow measurement is used together with temperature and humidity data to calculate air-side enthalpy difference and determine cooling or heating capacity.

Electrical Parameter Monitoring

The system records electrical parameters of the air conditioner under test, including voltage, current, power, frequency and power factor.

Parameter Measurement Range
Voltage 0–300 V
Current 0–20 A
Power 0–5 kW
Frequency 50 / 60 Hz
Power Factor 0–1

These values are recorded by the computerized data acquisition system and used for performance and energy efficiency calculation.

Computerized Control and Data Acquisition

The air enthalpy calorimeter uses a computer-based control platform for test condition management, data collection and performance calculation.

Key functions include:

  • Real-time monitoring of temperature, humidity, airflow and electrical parameters
  • Automatic data logging during the test process
  • Cooling and heating capacity calculation
  • EER and COP calculation according to the selected test method
  • Graphical data display and report output
  • Test condition control for repeatable laboratory operation

This automated workflow reduces manual recording errors and helps laboratories maintain consistent test procedures.

Air Enthalpy Calorimeter Technical

Test Capacity and Configuration

Parameter Specification
Applicable Standard ISO 5151 related air conditioner performance testing
Test Object Air conditioners and air-to-air heat pump products
Cooling Capacity Range 6,000–60,000 BTU/h
Heating Capacity Range 6,000–60,000 BTU/h
Test Configuration Dual-station air enthalpy calorimeter system
Station A Capacity 6,000–60,000 BTU/h
Station B Capacity 6,000–30,000 BTU/h
Test Chamber Type Indoor chamber + outdoor chamber
Applicable AC Types Split units, window units, freestanding units, cassette-type units and inverter air conditioners
Maximum Window Unit Size W1000 × D800 × H1000 mm
Maximum Split Unit Size W1000 × D500 × H2000 mm

Airflow and Electrical Measurement

Parameter Specification
Indoor Airflow Range 300–4,000 m³/h
Outdoor Airflow Range 200–2,000 m³/h
Voltage Measurement 0–300 V
Current Measurement 0–20 A
Power Measurement 0–5 kW
Frequency 50 / 60 Hz
Power Factor 0–1
Control System Computer automatic control
Data Acquisition Temperature, humidity, airflow and electrical parameters

 

Get Free Quote for ISO 5151 Air Enthalpy Calorimeter

We supply dual code air enthalpy calorimeter systems designed for professional HVAC performance laboratories.

The Core Value We Deliver to You

  • Complete HVAC testing solution for ISO 5151
  • Dual station testing improves laboratory efficiency
  • Computerized control for automatic measurement
  • Wide capacity range up to 60,000 BTU/h
  • Engineering support for laboratory setup

Submit an inquiry to receive technical specifications, quotation, and project consultation within 24 hours.

Applications and Laboratory Value

The ISO 5151 Air Enthalpy Calorimeter is suitable for HVAC manufacturers, third-party testing laboratories, certification support laboratories and R&D centers.

Typical applications include:

  1. Air Conditioner Performance Testing
    Measures cooling and heating capacity under controlled indoor and outdoor test conditions.
  2. Energy Efficiency Evaluation
    Supports calculation of performance indicators such as EER, COP and electrical input.
  3. Product Development and Engineering Validation
    Helps engineering teams compare compressor, heat exchanger, fan and system control performance during product development.
  4. Production Quality Verification
    Supports batch performance checking and product consistency verification before shipment.
  5. Certification Preparation
    Provides laboratory test data and performance documentation for standard-related evaluation.

Standards and Calibration Support

The system is designed for ISO 5151-related air conditioner performance testing. It can also be configured according to customer laboratory requirements for related air conditioner performance test methods.

Typical standard references may include:

  • ISO 5151 — Non-ducted air conditioners and heat pumps — Testing and rating for performance
  • GB/T 7725 — Room air conditioners
  • Other regional or customer-specified HVAC performance test methods, subject to final configuration review

To maintain measurement reliability, periodic verification or calibration of airflow sensors, temperature sensors, humidity sensors and electrical measurement instruments is recommended.


Procurement Value

For laboratories establishing or upgrading HVAC performance testing capability, the ISO 5151 Air Enthalpy Calorimeter provides a complete and repeatable platform for air conditioner capacity and energy efficiency evaluation.

Key benefits include:

  • Cooling and heating capacity measurement under controlled conditions
  • Dual-station design for improved laboratory productivity
  • Integrated airflow, environmental and electrical measurement
  • Automated data acquisition and report generation
  • Flexible configuration for different residential air conditioner capacities
  • Suitable for R&D, quality control and certification preparation

Air Enthalpy Calorimeter Detail

What is an air enthalpy calorimeter used for?

What is an air enthalpy calorimeter used for?
It measures the cooling and heating capacity of air conditioners by calculating the enthalpy difference of air passing through the system.
What is an air enthalpy calorimeter used for?
The system is mainly designed for ISO 5151 air conditioner performance testing.
What is the maximum testing capacity?
The system supports testing up to 60,000 BTU/h cooling capacity.
Can two air conditioners be tested simultaneously?
Yes, the dual station system allows testing two units up to 30,000 BTU/h each.
What parameters are measured?
Cooling capacity, heating capacity, airflow, voltage, current, power, frequency, and EER/COP.
What types of air conditioners can be tested?
Split, window, freestanding, ceiling box, duct type, and inverter air conditioners.
What airflow ranges are supported?
Indoor airflow up to 4000 m³/h and outdoor airflow up to 2000 m³/h.
What is the delivery time?
Typical delivery time is around 3 months depending on system configuration.
How can I request a quotation?
Submit an inquiry or contact KingPo sales for system configuration and pricing.
Is installation support available?
Yes, installation and commissioning support can be provided.

Related Products

Related News

Abstract / Technical Summary Learning how to test an EV charger tester is essential for manufacturers and laboratories performing EV […]

Abstract & Technical Summary Energy efficiency testing systems integrate high-precision power analysis, thermal performance modeling, and standardized testing methodologies to […]

IEC60456 Water Supply System streamlines compliance with automated controls, reliable data logging, and multi-station testing for accurate results.
IEC 61855 Automatic Airflow Performance Measurement streamlines hair dryer compliance with accurate, automated testing and audit-ready reports every time.
IEC 61591:2014 compliance ensures Range Hood Air Performance Air Volume Testing System delivers accurate, reliable results for certification and market access.
Vacuum Cleaner Air Performance Testing System automates IEC 60312 compliance, delivering accurate, repeatable results for faster certification and market entry.
Ensure ISO 14117 compliance for AIMDs by using a Defibrillation Test Pulse Generator to meet safety standards and document reliable defibrillation immunity testing.

Dongguan, China – 10 25, 2024 – In a significant advancement for food safety technology, Chao Zhang (also known as […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.