Neatly flat-folded stack of additive-free cellulose paper for IEC 60695 glow wire testing, showing multiple layers on laboratory bench
Thick multi-layer folded additive-free cellulose paper prepared as wrapping tissue for glow wire flammability test
Partially unfolded view of IEC tissue paper showing individual sheets and serrated edge for glow wire test use
Wave-folded cellulose paper placed on dark laboratory work surface for glow wire fire hazard evaluation
Neatly flat-folded stack of additive-free cellulose paper for IEC 60695 glow wire testing, showing multiple layers on laboratory bench
Thick multi-layer folded additive-free cellulose paper prepared as wrapping tissue for glow wire flammability test
Partially unfolded view of IEC tissue paper showing individual sheets and serrated edge for glow wire test use
Wave-folded cellulose paper placed on dark laboratory work surface for glow wire fire hazard evaluation

IEC 60695-2-10 Additive-Free Cellulose Paper for Glow Wire Test

Additive-Free Cellulose Paper is used with glow wire test equipment as IEC tissue paper / wrapping tissue for IEC 60695 glow wire flammability testing. It helps laboratories observe whether flaming particles, burning droplets or molten material from the test specimen ignite the specified paper layer during fire hazard evaluation.

  • Standard Test Application: Designed for use as wrapping tissue in IEC 60695 glow wire test setups
  • Material Type: Additive-free cellulose paper for consistent ignition observation during flammability testing
  • Typical Specification Range: 12 g/m² to 30 g/m², depending on selected configuration
  • Test Function: Helps evaluate whether flaming particles, molten drops or burning debris ignite the tissue layer
  • Testing Compatibility: Suitable for glow wire testing machines and related IEC 60695 fire hazard test procedures
  • Laboratory Use: Applied in routine glow wire flammability testing, material evaluation and quality documentation
  • Consumable Format: Supplied as glow wire test tissue paper / wrapping tissue for repeated laboratory use
  • Related Accessories: Type K thermocouple, U-type glow wire head and silver foil can be supplied separately when required

Additive-Free Cellulose Paper Description

IEC Tissue Paper , Glow Wire Test Consumable / Accessories for Flaming

Additive-Free Cellulose Paper for Glow Wire Test is a consumable tissue paper used in IEC 60695 glow wire testing. During the test, the paper is placed below the test specimen to help evaluate whether falling particles, molten drops or flaming debris can ignite the surrounding combustible layer.

The paper is commonly used with glow wire testing machines for electrical and electronic products, insulating materials, plastic components, household appliance parts, connectors, switches and other components requiring fire hazard evaluation. Its purpose is not to test the paper itself, but to provide a controlled observation layer during the glow wire test.

This IEC tissue paper is suitable for laboratories that require clean, additive-free cellulose paper for repeatable glow wire test observation and documentation. The available paper specification is generally selected according to the applicable test method and customer testing procedure.

Technical Parameters

Parameter Specification Remark or Notes
Product Name Additive-Free Cellulose Paper For glow wire test applications
Standard Application IEC 60695-2-10 glow wire test procedure Also used with related IEC 60695 glow wire test methods
Common Product Name IEC tissue paper / glow wire test wrapping tissue Consumable for glow wire flammability testing
Material Cellulose paper Additive-free type available according to customer requirement
Typical Grammage Range 12 g/m² to 30 g/m² Confirm according to selected configuration
Test Use Observation of ignition caused by flaming particles, molten drops or burning debris Used below the test specimen in glow wire test setup
Compatible Equipment Glow wire testing machine For IEC 60695 glow wire test applications
Packaging Carton box or laboratory consumable packaging Confirm before order
Related Consumables Type K thermocouple, U-type glow wire head, 0.06 mm silver foil Available separately if required

 

Common Error Mitigation

To maintain reliable glow wire test observation, laboratories should use the specified Additive-Free Cellulose Paper instead of ordinary tissue paper. The paper type, grammage and placement method should be confirmed according to the applicable IEC 60695 test procedure.

Before testing, keep the paper clean, dry and free from oil, dust or handling contamination. Moisture absorption or surface contamination may affect ignition behavior and reduce result consistency.

Each test should use fresh cellulose paper. Reusing paper or using incorrectly positioned paper may affect the observation of molten drops, flaming particles and ignition of the wrapping tissue layer.

Testing Principle

During a glow wire test, the test specimen is exposed to a heated glow wire under controlled conditions. Additive-Free Cellulose Paper is placed below the specimen as a wrapping tissue layer to observe whether flaming particles, molten drops or burning debris ignite the paper.

The observation helps laboratories evaluate fire hazard behavior beyond the specimen itself. If falling material ignites the tissue layer, the result may affect the assessment according to the applicable IEC 60695 test method.

This paper is a consumable accessory, not the main testing instrument. It should be used together with a properly configured glow wire testing machine, suitable glow wire head, temperature measurement system and other required test accessories.

Applications and Use Cases

Additive-Free Cellulose Paper is used in laboratories and production quality control environments where glow wire flammability testing is required.

Typical applications include:

  • IEC 60695 glow wire flammability testing
  • Fire hazard evaluation of electrical and electronic components
  • Testing of insulating materials, plastic parts and molded components
  • Household appliance component safety testing
  • Switch, connector and terminal block material testing
  • Quality inspection for electrical product certification preparation
  • Routine consumable replacement for glow wire testing machines

Compliance & Regulatory Assurance

This additive-free cellulose paper is prepared for use as wrapping tissue in IEC 60695-2-10 glow wire test procedures. It supports laboratories in observing whether molten drops, flaming particles or burning debris ignite the tissue layer during glow wire fire hazard evaluation.

Download Product Documentation

Technical Inquiry & Expert Support

KingPo can provide Additive-Free Cellulose Paper for glow wire test applications, together with related consumables such as thermocouples, U-type glow wire heads and silver foil. For quotation or configuration confirmation, please provide the applicable standard, required paper specification, testing machine model and expected order quantity.

The Core Value We Deliver

  • Additive-Free Cellulose Paper for IEC 60695 glow wire test applications
  • Suitable wrapping tissue for observing ignition from molten drops or flaming particles
  • Typical 12 g/m² to 30 g/m² specification range for laboratory selection
  • Supports repeatable glow wire test setup and quality documentation
  • Available with related glow wire test consumables and accessories

IEC 60695-2-10 Additive-Free Cellulose Paper for Glow Wire Test

IEC 60695-2-10 Additive-Free Cellulose Paper for Glow Wire Test FAQs

What is Additive-Free Cellulose Paper used for in glow wire testing?
Additive-Free Cellulose Paper is used as IEC tissue paper or wrapping tissue in glow wire flammability testing. It is placed below the test specimen to observe whether flaming particles, molten drops or burning debris ignite the paper during the test.
Is this paper used with a glow wire testing machine?
Yes. This cellulose paper is intended for use with glow wire testing machines in IEC 60695 fire hazard testing. It is a consumable accessory and should be used together with the glow wire apparatus, suitable test fixtures and required temperature measurement accessories.
Which standards are related to this product?
The main application is IEC 60695-2-10 glow wire apparatus and common test procedure. It is also relevant to related IEC 60695-2-11, IEC 60695-2-12 and IEC 60695-2-13 glow wire test methods where wrapping tissue or ignition observation may be required.
What is the typical grammage of this glow wire test paper?
The available specification range is typically 12 g/m² to 30 g/m². The exact paper grammage should be selected according to the applicable test standard, laboratory procedure and customer requirement before ordering.
Is Additive-Free Cellulose Paper the same as ordinary tissue paper?
No. Ordinary tissue paper may contain additives, coatings or properties unsuitable for controlled laboratory testing. Additive-Free Cellulose Paper is supplied for glow wire test applications where clean, consistent wrapping tissue is required for ignition observation.
Does this product include the glow wire tester?
No. This product is a consumable paper for glow wire testing, not the glow wire testing machine itself. It can be supplied together with related accessories such as Type K thermocouples, U-type glow wire heads and silver foil when required.
What industries commonly use this paper?
It is commonly used by electrical and electronic product manufacturers, material testing laboratories, household appliance testing labs, certification support laboratories and quality inspection institutions performing IEC 60695 glow wire flammability tests.
Why is wrapping tissue used in glow wire testing?
Wrapping tissue helps evaluate whether material falling from the test specimen can ignite a surrounding combustible layer. This observation is important in glow wire fire hazard assessment, especially when flaming particles or molten drops occur during the test.
How should the paper be stored before testing?
The paper should be stored in a clean, dry environment and protected from moisture, dust, oil and mechanical damage. Laboratories should follow the applicable test standard and internal conditioning procedure before formal testing.
What information should be provided before ordering?
Customers should provide the applicable IEC 60695 test method, required paper grammage, expected quantity, glow wire tester model and whether related consumables such as thermocouples, U-type glow wire heads or silver foil are also required.

Related Products

Related News

——IEC 60695-11-3 / IEC 60950 / UL94 500W Flame Test Practice and Cable Flammability Standard Comparison In the flammability safety […]

What are the key differences between glow wire tests and other wire insulation tests for electrical? Compare fire resistance focus with insulation performance.

KingPo HCT IEC 60335 Test Equipment Delivered to Korea Seoul, Korea — Jun 2021 — High-precision KingPo HCT IEC 60335 test […]

The Glow Wire Tester is a critical instrument in the rigorous landscape of electrical safety compliance, where a ‘Pass’ or […]

Introduction: The Hidden Threat in Your Devices Every year, thousands of residential and industrial fires are traced back to a […]

The glow wire test (GWT) is a cornerstone fire hazard assessment method in electrical and electronic product safety, as defined […]

Key Takeaways IEC 60695 series standardizes fire hazard testing for electrotechnical products using glow-wire (GWEPT/GWFI/GWIT), needle flame, and 50W/500W horizontal/vertical […]

Glow Wire Tester checks if electronics resist fire, ensuring your devices meet safety standards and protect your home from electrical fire hazards.
Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.