Standardized specimen holder used in EN ISO 1182 Non-Combustibility Test Apparatus
EN ISO 1182 Non-Combustibility Test Apparatus for building material fire testing
Close-up view of vertical tube furnace in EN ISO 1182 Non-Combustibility Test Apparatus
Standardized specimen holder used in EN ISO 1182 Non-Combustibility Test Apparatus
EN ISO 1182 Non-Combustibility Test Apparatus for building material fire testing
Close-up view of vertical tube furnace in EN ISO 1182 Non-Combustibility Test Apparatus

EN ISO 1182 Non-Combustibility Test Apparatus

The EN ISO 1182 Non-Combustibility Test Apparatus enables manufacturers and testing laboratories to determine the non-combustibility of building materials by exposing specimens to 750°C in a vertical tube furnace, in accordance with EN ISO 1182.

  • Standard Compliance: Fully compliant with EN ISO 1182 for non-combustibility testing of building materials
  • Vertical Tube Furnace: Designed to maintain a stable temperature of 750°C during testing
  • Precise Temperature Monitoring: Equipped with thermocouples to monitor both furnace and specimen temperatures
  • Specimen Holder: Standardized holder with a weight of 15 g ± 2 g
  • Stable Power Supply: Includes voltage stabilizer to ensure consistent test conditions
  • User-Friendly Operation: Easy-to-operate control system with direct result display
  • MOQ: 1 set
  • Delivery Time: 30 working days

EN ISO 1182 Non-Combustibility Test Apparatus Description

Non-Combustibility Test (EN ISO 1182)

The EN ISO 1182 Non-Combustibility Test Apparatus evaluates the combustibility of building materials by placing a specimen in a vertical tube furnace preheated to 750°C. The test observes whether the material sustains flaming and records any temperature rise to determine its non-combustibility performance.

This non-combustibility test furnace is essential for classifying construction products into fire performance categories such as A1 and A2. It helps manufacturers, testing laboratories, and certification bodies assess the fire safety of materials used in walls, ceilings, insulation, and other building applications under standardized high-temperature conditions.

Technical Parameters

Parameter Specification Remark / Notes
Applicable Standard EN ISO 1182 Non-combustibility test for building materials
Furnace Type Vertical tube furnace Φ95 mm × Φ75 mm × 150 mm
Test Temperature 750°C
Specimen Holder Weight 15 g ± 2 g Standardized
Thermocouple Insulated shield, Φ3 mm nickel-chrome For furnace and specimen temperature monitoring
Power Supply AC 220V ±10%, 50Hz With voltage stabilizer
Timer 0–99 hours
Thermometer Range 0–1000°C Accuracy ±5%

 

Professional Construction & Technical Precision

The EN ISO 1182 Non-Combustibility Test Apparatus features a vertical tube furnace designed to maintain a stable temperature of 750°C. The furnace construction, combined with precise thermocouple placement, ensures accurate monitoring of both the furnace environment and the specimen temperature throughout the test.

The equipment includes a standardized specimen holder and a stable power supply system with voltage regulation. These features help laboratories achieve consistent and repeatable test conditions, which are critical for reliable non-combustibility evaluation of building materials.

Testing Principle

In the EN ISO 1182 test, a specimen is placed into a vertical tube furnace preheated to 750°C. The test observes whether the material exhibits sustained flaming and records any temperature rise above the furnace temperature using thermocouples. Materials that do not sustain flaming and show limited temperature rise are classified as non-combustible.

This method provides a standardized way to assess the inherent combustibility of building materials, independent of their thickness or density.

Common Error Mitigation

To obtain accurate and consistent non-combustibility test results, the following practices are recommended:

  • Ensure the furnace reaches and maintains a stable temperature of 750°C before inserting the specimen.
  • Use properly prepared and conditioned specimens according to the standard requirements.
  • Correctly position the thermocouples to accurately monitor both furnace and specimen temperatures.
  • Avoid drafts or airflow disturbances around the furnace during testing.
  • Regularly calibrate the temperature measurement system and timer to maintain accuracy.

Applications & Use Cases

Laboratory technician operating EN ISO 1182 Non-Combustibility Test Apparatus
EN ISO 1182 Non-Combustibility Test Apparatus

The EN ISO 1182 Non-Combustibility Test Apparatus helps building material manufacturers and testing laboratories determine the non-combustibility of construction products. It supports fire safety classification, product development, and regulatory compliance for materials used in walls, ceilings, insulation, and other building applications.

  • Building material manufacturers — Conducting non-combustibility testing of construction products such as insulation, wall panels, and ceiling boards to support A1 and A2 fire classification in accordance with EN ISO 1182.
  • Testing laboratories — Performing EN ISO 1182 compliance testing and issuing formal reports on the non-combustibility performance of building materials under 750°C furnace conditions.
  • Certification bodies — Assessing and verifying the non-combustibility of building materials as part of A1 and A2 fire classification, supporting regulatory approval for construction products.
  • Research institutions and material developers — Studying the combustion behavior of new building materials, composites, and coatings under the standardized 750°C conditions of the EN ISO 1182 vertical tube furnace.
  • Quality control departments — Carrying out routine non-combustibility verification during production to ensure batch consistency and maintain compliance with fire performance requirements.

Key Advantages

This EN ISO 1182 Non-Combustibility Test Apparatus is designed to meet EN ISO 1182 requirements for determining the non-combustibility of building materials. It provides manufacturers and testing laboratories with a reliable method to evaluate whether construction products sustain combustion at 750°C, supporting A1 and A2 fire classification.

The equipment features a stable vertical tube furnace with precise temperature control at 750°C, standardized specimen holders, and accurate thermocouple monitoring. These capabilities enable consistent and repeatable test results, while its user-friendly design with direct result display helps laboratories perform reliable non-combustibility evaluation with reduced operational complexity.

Compliance & Calibration Support

This EN ISO 1182 Non-Combustibility Test Apparatus is designed to perform tests in full accordance with EN ISO 1182. It supports laboratories in determining the non-combustibility of building materials for fire classification purposes.

Metrological Integrity & Validation

  • The temperature measurement system and timer should be periodically calibrated.
  • Regular inspection of the furnace and thermocouples is recommended to maintain test accuracy.
  • Proper maintenance helps ensure stable furnace temperature and reliable test conditions.

Download Product Documentation

Technical Inquiry & Expert Support

KingPo supplies EN ISO 1182 Non-Combustibility Test Apparatuses for building material fire testing. Our team can provide guidance on equipment operation, test setup, and compliance with non-combustibility testing standards. For technical specifications or quotations, please contact us.

The Core Value We Deliver

  • Reliable EN ISO 1182 non-combustibility testing for building materials
  • Stable 750°C vertical tube furnace with precise temperature monitoring
  • Supports fire classification of construction products for A1 and A2 ratings
  • Easy operation with direct result display
  • Technical support for equipment use and standard application

EN ISO 1182 Non-Combustibility Test Apparatus Detail Display

EN ISO 1182 Non-Combustibility Test Apparatus FAQs

What is the EN ISO 1182 Non-Combustibility Test Apparatus used for?
The EN ISO 1182 Non-Combustibility Test Apparatus is used to determine whether building materials are non-combustible by exposing specimens to a temperature of 750°C in a vertical tube furnace and observing their reaction.
Which standard does this Non-Combustibility Test Apparatus comply with?
This apparatus is designed to fully comply with EN ISO 1182 for determining the non-combustibility of building materials and is widely used for fire classification of construction products.
What temperature is used during the EN ISO 1182 test?
The test is conducted at a furnace temperature of 750°C. The specimen is exposed to this temperature, and any sustained flaming or temperature rise is recorded to assess combustibility.
What does the EN ISO 1182 test measure?
The test measures whether a building material sustains flaming and records any temperature rise above the furnace temperature. Materials that do not exhibit sustained flaming and show limited temperature rise are classified as non-combustible.
Who typically uses the EN ISO 1182 Non-Combustibility Test Apparatus?
It is commonly used by building material manufacturers, testing laboratories, certification bodies, and research institutions involved in fire safety evaluation and classification of construction products.
What types of materials can be tested with this apparatus?
This non-combustibility test furnace is suitable for testing both homogeneous products and substantial components of non-homogeneous building materials, such as insulation, panels, and other construction products.
How is the test performed in the EN ISO 1182 apparatus?
A specimen is placed into a vertical tube furnace preheated to 750°C. The test observes whether the material sustains flaming and uses thermocouples to monitor temperature changes throughout the test duration.
How can accurate and consistent test results be ensured?
Accurate results require stable furnace temperature at 750°C, correct specimen preparation, proper thermocouple placement, and regular calibration of the temperature measurement system and timer.
Is the EN ISO 1182 test mandatory for building materials?
While not always mandatory, the EN ISO 1182 test is frequently required for achieving A1 and A2 fire classifications in many European and international building regulations and certification schemes.
What fire classifications does the EN ISO 1182 test support?
This test is used to support fire classification of building materials, particularly for A1 and A2 ratings, as part of the European reaction to fire classification system (EN 13501-1)

Related Products

Related News

Application and Technical Analysis of Glow Wire Test Apparatus in Flame Retardancy Performance Testi for electrical and electronic products and plastics.

——IEC 60695-11-3 / IEC 60950 / UL94 500W Flame Test Practice and Cable Flammability Standard Comparison In the flammability safety […]

Abstract The IEC 60332-1-2 Cable Flammability Test serves as a critical benchmark for evaluating the fire safety integrity of modern […]

Meet UL94 and IEC standards with the horizontal vertical flame tester. Follow step-by-step testing and compliance procedures for reliable fire safety results.
Vertical Flame Tester offers stricter cable safety by simulating severe fire risks, while horizontal testers suit low-risk checks. Choose based on your application.
A Needle Flame Tester evaluates material fire resistance by applying a small, controlled flame to test ignition and self-extinguishing properties.

For plastic insulation frames, given the high heat generated by the copper wires and iron core, if the flame retardant […]

In an era where product safety is paramount, flammability and flame retardant testing have become indispensable across multiple high-stakes industries: […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.