ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing
ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing

ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing

ISO 80369-2 Socket Gauge ensures precise R1 cone connector verification with durable construction for reliable medical safety compliance.

  • Standard Compliance: ISO 80369-2 Figure C.1 โ€“ exact socket reference gauge for R1 cone connectors
  • Material: High-hardness steel with HRC 58-62
  • Test Functions: Leakage, separation from unscrewing, stress cracking and non-interconnectable characteristics
  • Application: Testing of small-bore medical connectors for patient safety
  • Precision: Manufactured to exact dimensional tolerances per ISO 80369-2
  • MOQ: 1 / Delivery Period: 7 working days

ISO 80369-2 Figure C.1 Socket Gauge Description

ISO 80369-2 Figure C.1 Socket Gauge | R1 Cone Connector Testing

The ISO 80369-2 Figure C.1 Socket Gauge | R1 Cone Connector Testing is a precision reference connector manufactured by KingPo. It is specifically designed as a socket gauge for verifying the performance and safety of R1 cone connectors in small-bore medical connection systems, fully compliant with ISO 80369-2 Figure C.1.

Technical Parameters

Parameter Specification Remark / Notes
Standard ISO 80369-2 Figure C.1 Socket reference gauge for R1 cone connectors
Material Hardened steel High wear resistance and long-term dimensional stability
Hardness HRC 58-62 Ensures durability under repeated testing cycles
Gauge Type Socket reference connector Used to test leakage, unscrewing separation, stress cracking and non-interconnectability
Manufacturing Tolerance Exact dimensions per ISO 80369-2 Figure C.1 Guarantees repeatable and traceable test results
Certification ISO 17025 traceable calibration certificate Supports laboratory accreditation and audit requirements

 

Professional Construction & Technical Precision

The socket gauge is precision-machined from high-hardness steel (HRC 58-62) to achieve exact dimensional tolerances as specified in ISO 80369-2 Figure C.1. The internal geometry is carefully controlled to simulate real-world connection conditions while maintaining consistent contact surfaces for reliable leakage, separation, and stress cracking tests.

All critical surfaces are ground and polished to minimize friction variability and ensure long-term dimensional stability even after thousands of test cycles. The robust construction and surface finish prevent deformation or wear that could compromise test accuracy.

Testing Principle

The gauge is mated with the R1 cone connector under controlled conditions to evaluate leakage, resistance to unscrewing separation, susceptibility to stress cracking, and prevention of misconnections with other small-bore connectors as defined in ISO 80369-2.

Common Error Mitigation

To ensure repeatable results, always align the connector axially without lateral force and verify that the gauge is clean and free of debris before each test. Regular visual inspection and periodic recalibration help maintain measurement integrity and prevent false pass/fail outcomes.

ISO 80369-2 Figure C.1 Socket Gauge for R1 Cone Connector Testing

Primary Use Cases & Business Value

The ISO 80369-2 Figure C.1 Socket Gauge is used by medical device manufacturers and certification laboratories to verify the safety and performance of R1 cone connectors in small-bore medical systems. It helps ensure patient safety by preventing misconnections, leakage, and mechanical failures in critical fluid and gas delivery applications.

Industrial Applications & Lab Scenarios

  • Medical device manufacturers โ€“ performance and safety validation of R1 cone connectors per ISO 80369-2
  • Third-party certification laboratories โ€“ traceable compliance testing of small-bore medical connectors
  • R&D departments โ€“ development and optimization of new connector designs to eliminate misconnections
  • Quality control teams โ€“ batch verification of connectors used in enteral, respiratory and infusion systems
  • Regulatory compliance teams โ€“ demonstration of non-interconnectability and mechanical integrity requirements

Strategic Procurement Advantages & Global Support

  • High-Efficiency Testing: Precision socket gauge enables fast, repeatable ISO 80369-2 Figure C.1 testing with minimal setup time.
  • Certified Manufacturing: ISO 9001/14001/45001 and CE certified production with ISO 17025 traceability ensures laboratory-grade reliability.
  • Reliability & Support: Each unit undergoes rigorous factory calibration in our Dongguan facility and is backed by a full one-year warranty, on-site installation guidance, and lifetime technical engineering support.

Compliance & Regulatory Assurance

This equipment is manufactured in full accordance with ISO 80369-2 Figure C.1 for testing R1 cone connectors in small-bore medical connection systems. It provides a standardized, reproducible test method essential for demonstrating compliance with international requirements for leakage prevention, mechanical integrity and non-interconnectability.

For detailed information on testing procedures, please refer to the latest edition of ISO 80369-2. Regular visual inspection and recalibration are recommended to maintain accuracy.

Technical Inquiry for ISO 80369-2 Figure C.1 Socket Gauge

The Core Value We Deliver to You

  • Exact replication of ISO 80369-2 Figure C.1 geometry for accurate R1 cone connector testing
  • High-hardness steel (HRC 58-62) construction for long-term dimensional stability
  • ISO 17025 traceable calibration certificate included
  • Designed for leakage, separation, stress cracking and non-interconnectability tests
  • Ideal for both product development and regulatory compliance testing

Tell us your connector type or test requirements โ€” our engineering team will reply with tailored recommendations within 24 hours. Submit Technical Inquiry

FAQ

What is the ISO 80369-2 Figure C.1 Socket Gauge used for?
It serves as the socket reference connector to test R1 cone connectors for leakage, unscrewing separation, stress cracking, and non-interconnectability.
Which standards does this gauge comply with?
Fully compliant with ISO 80369-2:2024 (respiratory connectors), includes ISO 17025 calibration certificate.
What material is the gauge made from?
Hardened steel with HRC58-62 hardness for precision, durability, and wear resistance.
What is the MOQ for this socket gauge?
MOQ is 1 unit, suitable for labs, R&D, or compliance testing. Bulk discounts available.
How long is the typical delivery time?
Standard: 7 working days after order. Expedited options for urgent needs.
Does it support customization?
Yesโ€”contact for any special calibration or modifications.
What tests does it enable on R1 cone connectors?
Leakage under pressure, separation by unscrewing, stress cracking, and non-interconnectable performance.
How does it support respiratory device safety?
By verifying connectors resist failures and misconnections in low-pressure breathing systems (up to 15 kPa).
What warranty and support are provided?
Factory support with calibration assistance and reliable after-sales for ongoing use.
How does this gauge reduce compliance costs?
In-house accurate testing avoids repeated third-party fees, speeds validation, and ensures durable performance.

Related Products

Related News

The Ultimate Guide to ISO 80369 Luer Gauge Testing ensures your connectors meet safety standards, prevent misconnections, and maintain compliance with reliable testing procedures.
Manufacturers perform glow wire tests by heating a wire and applying it to electrical components to assess fire resistance and meet safety standards.
KP-1065S Pulse Voltage Generator boosts surge testing efficiency, safety, and IEC 62368-1 compliance for advanced electronics and production lines.

For plastic insulation frames, given the high heat generated by the copper wires and iron core, if the flame retardant […]

Shan Chao 1 , Qiang Xiaolong 2 , Liu jiming 3 , Zhang Chao 3 . (1. Heilongjiang Institute for […]

A LUER GAUGE checks medical device connectors for secure fit, preventing leaks and ensuring patient safety in clinical settings.

You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]

Abstract Thermage, a non-invasive radiofrequency (RF) skin tightening technology, is widely used in medical aesthetics. With operating frequencies increasing to […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.