ISO 80369-7 Figure C.3 Female Reference Connector
The ISO 80369-7 Figure C.3 Female Reference Connector is a standard reference connector used for testing male Luer lock connectors in intravascular and hypodermic medical device applications. It provides the specified female reference interface for ISO 80369-7 related Luer lock connector evaluations.
- Applicable Standard: ISO 80369-7 Figure C.3 / Annex C
- Product Type: Female Reference Connector
- Test Object: Male Luer lock connectors
- Typical Use: Reference mating connector for ISO 80369-7 related Luer lock connector testing
- Thread Note: Double-start, right-hand thread of 2.5 mm pitch
- Important Limitation: Figure C.3 should be used only for the applicable test configuration and should not be treated as a universal female reference connector
- Supply Option: Individual Figure C.3 connector or part of the complete ISO 80369-7 Luer Gauge Set
- Related Equipment: Used with applicable ISO 80369-20 test setups when performance testing is required
Product Overview
ISO 80369-7 Figure C.3 Female Reference Connector
The ISO 80369-7 Figure C.3 Female Reference Connector is used as a controlled mating component when evaluating male Luer lock connectors. It should not be confused with the ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector, Figure C.5 Female Reference Luer Slip Connector, or the ISO 80369-7 Female Ring Gauge.
In a typical test setup, the male Luer lock connector sample is mated with the Figure C.3 female reference connector. The assembled connection is then used in the applicable ISO 80369 test procedure according to the required evaluation item and sample structure.
This page is intended for customers who specifically require Figure C.3 for a male Luer lock connector test configuration. Customers who need multiple ISO 80369-7 reference connectors should consider the complete ISO 80369-7 Luer Gauge Set.
Key Drawing Notes and Use Limitation
Figure C.3 has its own geometry and use limitation, so it should not be treated as interchangeable with C.1, C.5 or a female ring gauge. The official Figure C.3 drawing notes include a double-start right-hand thread and a specific limitation for certain non-interconnectable characteristic evaluations.
| Item | Figure C.3 Note |
|---|---|
| Figure Number | ISO 80369-7 Figure C.3 |
| Reference Connector Type | Female reference connector |
| Test Object | Male Luer lock connectors |
| Thread Note | Double-start, right-hand thread of 2.5 mm pitch |
| Edge / Radius Note | Radius or chamfer not to exceed 0.5 mm |
| Important Limitation | This reference connector cannot be used for the test of non-interconnectable characteristics against its collar outside diameter because the corresponding defined range is wide and one single reference connector is not representative. |
| Dimension Unit | Millimetres unless otherwise indicated |
The Figure C.3 reference connector should be selected according to the required figure number and the test method. If the test item involves a specific collar outside diameter or non-interconnectable characteristic evaluation, the correct reference configuration should be confirmed before testing.

How It Is Used and What It Tests
Typical Use Procedure
- Confirm that the sample is a male Luer lock connector and that ISO 80369-7 Figure C.3 is the required reference connector.
- Mate the male Luer lock sample with the Figure C.3 female reference connector.
- Install the assembled connection into the applicable ISO 80369 test setup.
- Apply the required test condition according to the selected procedure.
- Record the result and inspect the connection according to the applicable test requirement.
- After testing, clean and protect the reference connector to avoid scratches, contamination or thread damage.
Typical Test Applications
The Figure C.3 connector is mainly used in ISO 80369-7 test configurations where a female reference connector is required for evaluating male Luer lock connectors. Typical applications may include:
- Male Luer lock connector mating evaluation
- Separation from unscrewing related test configurations
- Resistance to overriding evaluation where applicable
- Stress cracking related connector evaluation where the selected procedure requires Figure C.3
- Non-interconnectable characteristic evaluation only when the test configuration allows this reference connector
- Laboratory confirmation of male Luer lock connector fit and engagement
The exact test item should be confirmed according to the applicable ISO 80369-7 clause and ISO 80369-20 test method. The Figure C.3 connector itself is a reference connector, not a complete test apparatus.
Technical Features
- Designed according to ISO 80369-7 Figure C.3 reference connector geometry
- Female reference connector for male Luer lock connector testing
- Threaded reference interface for Luer lock connector evaluation
- Double-start, right-hand thread configuration according to the Figure C.3 drawing note
- Precision-machined mating surface for repeatable connector engagement
- Hardened steel or stainless steel configuration can be supplied according to the product specification.
- Material information, dimensional confirmation or hardness confirmation can be provided where applicable.
- Available individually or as part of the complete ISO 80369-7 Luer Gauge Set
- Suitable for R&D validation, laboratory testing and factory quality control
- Can be used with suitable ISO 80369-20 test equipment when performance testing is required
Operation and Handling Notes
The Figure C.3 connector should be handled as a precision reference component.
- Confirm the required figure number before testing.
- Do not replace Figure C.3 with Figure C.1, Figure C.5 or a female ring gauge unless the selected procedure clearly allows it.
- Confirm whether the tested sample is a male Luer lock connector.
- Check that the thread engagement is clean and free from visible damage.
- Do not force the connector onto an incompatible or damaged sample.
- Avoid impact, corrosion or contamination during storage and use.
- Store the connector in a protective case after testing.
- Confirm documentation requirements before order placement if the connector will be used in a regulated laboratory environment.
Compliance & Regulatory Assurance
This ISO 80369-7 Figure C.3 Female Reference Connector is manufactured according to the Figure C.3 reference connector geometry for male Luer lock connector testing. It supports ISO 80369-7 related connector evaluations when used with the appropriate test setup and procedure.
KINGPO can provide product datasheet, material information, dimensional confirmation or hardness confirmation where applicable. Please confirm any documentation requirement before order placement.
|
Product Datasheet
ISO 80369-7 Figure C.3 Female Reference ConnectorDownload the PDF datasheet for product overview, key drawing notes, use limitation, operation notes and technical inquiry support.
|
Download Datasheet |
Technical Inquiry & Expert Support
The ISO 80369-7 Figure C.3 Female Reference Connector is a standard reference connector manufactured according to the specified figure. To help KINGPO provide the correct item and supporting information, please include the following details when sending an inquiry:
- Required product: ISO 80369-7 Figure C.3 Female Reference Connector
- Quantity required
- Whether you need this connector individually or as part of the complete ISO 80369-7 C.1–C.6 Luer Gauge Set
- Your sample type, especially male Luer lock connector
- Intended test application, such as Luer lock mating evaluation, separation resistance or overriding resistance
- Whether related ISO 80369-20 test equipment is also required
- Any documentation requirement, such as dimensional report, material information or hardness confirmation
KINGPO can help review your connector type and test purpose before quotation to confirm whether Figure C.3 is the correct reference connector for your ISO 80369-7 test setup.
Related KINGPO ISO 80369 Products
| Related Product | Suggested Anchor Text |
|---|---|
| ISO 80369-7 Luer Gauge Set | ISO 80369-7 Luer Gauge Set |
| ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector | ISO 80369-7 Figure C.1 Female Reference Luer Lock Connector |
| ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector | ISO 80369-7 Figure C.5 Female Reference Luer Slip Connector |
| ISO 80369-7 Female Ring Gauge | ISO 80369-7 Female Ring Gauge |
| ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector | ISO 80369-7 Figure C.4 Male Reference Luer Lock Connector |
| ISO 80369-20 Liquid Leakage Tester | ISO 80369-20 Liquid Leakage Tester |
| ISO 80369-20 Annex D Air Leakage Tester | ISO 80369-20 Annex D Air Leakage Tester |
| ISO 80369-20 Annex F Axial Load Tester | ISO 80369-20 Annex F Axial Load Tester |
ISO 80369-7 Figure C.3 Female Reference Connector
FAQ
Related Products
Related News
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]