IEC 60601-2-3 Figure 201.102 Test Probe
The IEC 60601-2-3 Figure 201.102 Test Probe is used for dielectric strength testing of short-wave therapy equipment applicators. It provides a defined 8 mm metal contact surface with a smooth hemispherical end for repeatable insulation verification.
This probe is a mechanical contact accessory and should be used together with suitable dielectric strength test equipment and a controlled laboratory high-voltage test procedure.
- Designed for IEC 60601-2-3 Figure 201.102 dielectric strength test setup
- Used for short-wave therapy equipment applicator insulation verification
- Suitable for capacitive and inductive applicators
- 8 mm metal probe provides a defined and repeatable contact surface
- Smooth hemispherical end helps reduce sharp-edge contact effects
- Insulated handle supports safer positioning during high-voltage test preparation
- Compact mechanical structure for R&D, laboratory and production inspection use
- Product specification and dimensional information available for documentation support
IEC 60601-2-3 Figure 201.102 Test Probe Overview
The IEC 60601-2-3 Figure 201.102 Test Probe provides a standardized contact method for dielectric strength testing of short-wave therapy equipment applicators. It is used when the test procedure requires a defined probe geometry instead of a general metal rod or improvised contact tool.
With its 8 mm metal probe and smooth hemispherical end, the probe helps reduce contact variation during high-voltage insulation testing. It supports consistent applicator surface contact, repeatable test setup and clearer documentation for IEC 60601-2-3 related verification.
This test probe is suitable for medical device manufacturers, R&D teams, quality control departments and third-party laboratories performing applicator insulation checks, pre-compliance testing or routine production inspection.
Technical Parameters
Standard and Application Information
| Item | Specification | Remark or Notes |
|---|---|---|
| Product name | IEC 60601-2-3 Figure 201.102 Test Probe | Standard contact probe for applicator dielectric strength testing |
| Applicable standard | IEC 60601-2-3 Figure 201.102 | Main standard reference |
| Related clause | IEC 60601-2-3 Clause 201.8.8.3 | For short-wave therapy equipment applicator insulation verification |
| Product type | Dielectric strength test probe | Mechanical contact accessory |
| Test object | Short-wave therapy equipment applicators | Used on applicator surfaces according to the test procedure |
| Applicable applicators | Capacitive and inductive applicators | Confirm applicator structure before testing |
| Test purpose | Dielectric strength and insulation performance verification | Used with dielectric strength test equipment |
| Supporting equipment | Dielectric strength tester or high-voltage test system | The probe itself does not generate voltage |
Probe Geometry and Configuration
| Item | Specification | Remark or Notes |
| Probe diameter | 8 mm | Defined metal contact diameter |
| Probe end | Smooth hemispherical metal end | Helps maintain controlled surface contact |
| Total length | 100 mm | Standard probe length |
| Insulated handle diameter | Ø30 mm | Supports safer manual handling during test setup |
| Insulated handle length | 100 mm | For stable positioning and grip |
| Structure | Metal contact probe with insulated handle | Compact mechanical test accessory |
| Documentation | Product specification and dimensional information available | According to customer order requirement |
| Typical use stage | R&D verification, pre-compliance testing, production inspection and laboratory testing | Suitable for manufacturer and laboratory use |
Testing Principle and Standard Method

During testing, the IEC 60601-2-3 Figure 201.102 Test Probe is applied to the specified surface of the short-wave therapy equipment applicator. The dielectric strength test voltage is then applied between the probe and the relevant internal conductive part, electrode or connection point according to the selected test method.
The test verifies whether the applicator insulation can withstand the required voltage stress without dielectric breakdown. Final voltage, test duration, ramping method, connection position, breakdown judgment and post-test inspection should follow the applicable IEC 60601-2-3 edition and laboratory quality procedure.
The probe itself does not determine the pass or fail result. Test reliability depends on the complete setup, including dielectric strength tester performance, sample condition, probe position, contact surface condition, voltage setting and acceptance criteria.
Applications and Use Cases
The IEC 60601-2-3 Figure 201.102 Test Probe is used for short-wave therapy equipment safety evaluation, applicator insulation design validation, IEC 60601-2-3 pre-compliance testing, production quality inspection and third-party laboratory verification.
Typical users include medical device manufacturers, R&D teams, QA departments, inspection institutions, certification support teams and testing laboratories preparing for IEC 60601-2-3 related compliance testing.
This probe is especially useful when the test method requires a defined 8 mm contact probe rather than an improvised metal contact tool.
Operation and Test Notes
Before testing, operators should confirm the applicable IEC 60601-2-3 edition, test clause, applicator type, test voltage, test duration, connection method and acceptance criteria. The probe should be applied only to the specified test position defined by the laboratory procedure.
Because dielectric strength testing involves high voltage, the probe should only be used by trained personnel. The test area should be controlled, and users should follow the safety instructions of the dielectric strength tester and the laboratory high-voltage procedure.
Dimensional Verification and Maintenance
For formal compliance testing or routine quality control, periodic dimensional verification is recommended. The 8 mm probe diameter, smooth hemispherical end, total length and insulated handle condition should be checked according to the laboratory quality system.
The metal probe end should remain clean, smooth and free from corrosion, oil, dust or residue. After use, the probe should be cleaned and stored in a dry protective condition.
If deformation, tip damage, surface scratching, corrosion or insulation damage is found, the probe should not be used for formal dielectric strength testing until its condition has been confirmed.
Compliance & Regulatory Assurance
The IEC 60601-2-3 Figure 201.102 Test Probe helps laboratories establish a consistent contact condition for dielectric strength testing of short-wave therapy equipment applicators.
It is a mechanical contact accessory and does not replace full medical electrical equipment compliance assessment, risk management review, electrical safety testing, usability evaluation or final certification decision. For formal compliance testing, users should confirm the applicable standard edition, sample condition, dielectric strength test equipment, probe position, connection method and acceptance criteria with the responsible laboratory or certification body.
Metrological Integrity and Validation
- Product specification and dimensional information can be provided according to order requirements.
- Regular dimensional verification is recommended for frequent laboratory or production quality control use.
- The 8 mm probe diameter, smooth hemispherical end, total length and insulated handle condition should be checked according to the laboratory quality system.
- The probe should be protected from impact, deformation, corrosion and surface damage.
- If visible damage, abnormal wear, corrosion or insulation damage is found, the probe should be rechecked before formal dielectric strength testing.
- For compliance testing, users should keep relevant test records, dielectric strength tester calibration records and probe inspection records according to their internal quality system.
Download Product Documentation
Download the IEC 60601-2-3 Figure 201.102 Test Probe catalog with product overview, technical parameters, application notes and inquiry information.
Technical Inquiry & Expert Support
KingPo supplies the IEC 60601-2-3 Figure 201.102 Test Probe for dielectric strength testing of short-wave therapy equipment applicators. Our engineering team can help review whether this probe and the related documentation package match your IEC 60601-2-3 test clause, applicator type and laboratory dielectric strength test setup.
Please Provide the Following Information:
- Applicable standard: IEC 60601-2-3 or internal test procedure
- Related clause: Figure 201.102, Clause 201.8.8.3 or other dielectric strength test requirement
- Test object: Short-wave therapy equipment applicator
- Applicator type: Capacitive applicator, inductive applicator or other applicator structure
- Test requirement: Dielectric strength test voltage, test duration, connection method and acceptance criteria
- Test equipment: Dielectric strength tester model or laboratory high-voltage test system
- Probe requirement: 8 mm metal probe, smooth hemispherical end, insulated handle or drawing reference
- Documentation: Product specification, dimensional confirmation, inspection record or other quality document
- Customization needs: Marking, packaging, storage case, documentation package or special laboratory requirement
Based on this information, KingPo can provide product confirmation, documentation support and quotation for your IEC 60601-2-3 Figure 201.102 Test Probe requirement.
IEC 60601-2-3 Figure 201.102 Test Probe
IEC 60601-2-3 Figure 201.102 Test Probe FAQs
Related Products
Related News
Abstract / Technical Summary Selecting the right energy efficiency testing equipment is essential for appliance manufacturers to meet IEC, GB, […]
Abstract & Technical Summary Under the UK’s BS 7671 IET Wiring Regulations (18th Edition), electrical safety and circuit protection rely […]
The Ultimate Guide to Desktop Temperature Humidity Chamber in 2026: Precision High-Low Cycling, Environmental Adaptability, and Reliability Verification – A […]
Abstract Thermage, a non-invasive radiofrequency (RF) skin tightening technology, is widely used in medical aesthetics. With operating frequencies increasing to […]
KingPo completed the delivery of a customized HME Moisture Loss Measurement System to UL Solutions Suzhou Laboratory on March 23, […]