: Cone Tool for Medical Beds โ€“ KingPo Stainless Steel Cone Tool with Exact Weight and Surface Finish per BS EN 50637:2017 Figure 201.102a
Cone Tool for Medical Beds โ€“ KingPo BS EN 50637:2017 Precision Stainless Steel Test Tool Weighing 3.3 ยฑ 0.05 kg with 1.6 ฮผm Surface Roughness for Gap and Clearance Testing
Cone Tool for Medical Beds โ€“ KingPo Professional Safety Gap Test Tool for Childrenโ€™s Medical Beds and Pediatric Equipment
: Cone Tool for Medical Beds โ€“ KingPo Stainless Steel Cone Tool with Exact Weight and Surface Finish per BS EN 50637:2017 Figure 201.102a
Cone Tool for Medical Beds โ€“ KingPo BS EN 50637:2017 Precision Stainless Steel Test Tool Weighing 3.3 ยฑ 0.05 kg with 1.6 ฮผm Surface Roughness for Gap and Clearance Testing
Cone Tool for Medical Beds โ€“ KingPo Professional Safety Gap Test Tool for Childrenโ€™s Medical Beds and Pediatric Equipment

Cone Tool for Medical Beds โ€“ BS EN 50637:2017 Precision Safety Test Tool

Cone Tool for Medical Beds โ€“ precision stainless steel test tool manufactured to BS EN 50637:2017 Figure 201.102a for verifying safety gaps and clearance in childrenโ€™s medical beds. With a controlled weight of 3.3 ยฑ 0.05 kg and surface roughness of 1.6 ฮผm, it ensures accurate and repeatable safety testing.

  • Material: High-quality stainless steel
  • Total Weight: 3.3 ยฑ 0.05 kg
  • Surface Roughness: 1.6 ฮผm
  • Standard Compliance: BS EN 50637:2017 Figure 201.102a
  • Design: Precision cone shape for gap and clearance verification
  • Application: Safety testing of childrenโ€™s medical beds and similar equipment
  • Warranty: 1 year
  • MOQ: 1
  • Delivery Period: 7 working days

Cone Tool for Medical Beds Description

Cone Tool -medical Beds For Children, BS EN 50637:2017-Figure 201.102a

The Cone Tool for Medical Beds is a professional stainless steel test tool manufactured by KingPo in strict accordance with BS EN 50637:2017 Figure 201.102a. It is specifically designed for verifying safety gaps, clearances and entrapment hazards in childrenโ€™s medical beds and similar pediatric equipment.

With a precisely controlled weight of 3.3 ยฑ 0.05 kg and a surface roughness of 1.6 ฮผm, the tool provides consistent and repeatable test results that help manufacturers ensure compliance with the highest safety standards for pediatric medical devices. The cone geometry allows accurate simulation of real-world finger or limb entrapment scenarios, making it an essential tool for both product development and final quality inspection.

KingPo Factory Advantages

KingPo is an ISO9001 and CE certified manufacturer specializing in medical device test tools and safety testing equipment. We have supplied numerous BS EN 50637 cone tools to leading medical bed manufacturers and accredited laboratories worldwide. All units undergo rigorous dimensional and weight verification before shipment and are delivered with calibration certificates (additional cost), on-site installation guidance, a full one-year warranty and rapid 48-hour technical response from our Dongguan facility.

Cone Tool -medical beds for children-BS EN 50637-2017-Figure 201.102a

Professional Construction & Technical Precision

Key features include:

  • Precision-machined stainless steel construction with excellent corrosion resistance
  • Controlled total weight of 3.3 ยฑ 0.05 kg for repeatable testing
  • Surface roughness strictly maintained at 1.6 ฮผm to simulate realistic contact conditions
  • Cone geometry exactly matching BS EN 50637:2017 Figure 201.102a requirements
  • Compact and durable design suitable for laboratory and production floor use

These technical elements ensure the highest level of accuracy, repeatability and compliance with pediatric medical bed safety standards.

Technical Specifications

Parameter Specification Remark / Notes
Material Stainless Steel High-grade, corrosion-resistant, durable
Total Weight 3.3 ยฑ 0.05 kg Precision tolerance for repeatable safety gap testing
Surface Roughness 1.6 ฮผm Meets exact BS EN 50637:2017 requirement
Standard BS EN 50637:2017 Figure 201.102a Exact cone geometry for childrenโ€™s medical bed testing
Application Safety gap and clearance verification Designed for entrapment hazard testing

 

Primary Use Cases & Business Value

The cone tool for medical beds supports critical stages:

  • Product Development โ€“ Verify gap and clearance safety during design of childrenโ€™s medical beds
  • Certification Testing โ€“ Generate data for BS EN 50637:2017 compliance
  • Quality Control โ€“ Batch verification of safety gaps in production
  • Failure Analysis โ€“ Identify entrapment risks in existing pediatric equipment

It improves patient safety, reduces liability risks and accelerates certification for childrenโ€™s medical beds.

Procurement Benefits

The precision weight tolerance and surface finish deliver consistent, repeatable test results with minimal variation. The robust stainless steel construction ensures long-term durability and easy cleaning. This cone tool for medical beds strengthens safety gap verification, fully supports BS EN 50637:2017 and minimizes quality risks. Contact us today for your quote โ€“ we will respond within 24 hours with detailed technical specifications and pricing.

Cone Tool for Medical Beds Applications

  • Childrenโ€™s Medical Beds โ€“ Safety gap and entrapment testing per BS EN 50637:2017
  • Pediatric Hospital Equipment โ€“ Clearance verification for cots and beds
  • Production Quality Assurance โ€“ Batch testing of pediatric furniture
  • Certification Laboratories โ€“ Compliance verification for medical devices

Product Description

This equipment is strictly designed and manufactured in accordance with BS EN 50637:2017 Figure 201.102a for safety testing of childrenโ€™s medical beds. It provides a precise tool for accurate measurement of gaps and clearances, thereby ensuring patient safety and regulatory compliance in pediatric medical applications.

For a technical overview of the BS EN 50637:2017 standard for medical beds for children, refer to the British Standards technical reference.

Calibration certificates are available at additional cost. Regular verification of weight and surface roughness is recommended to maintain traceability.

Technical Inquiry for Cone Tool for Medical Beds

KingPo specializes in medical device safety test tools. If you require precise gap and clearance testing for childrenโ€™s medical beds according to BS EN 50637:2017, our engineering team can provide customized support and technical advice.

The Core Value We Deliver to You

  • Precision stainless steel construction with controlled weight 3.3 ยฑ 0.05 kg
  • Surface roughness exactly 1.6 ฮผm per standard
  • Exact geometry matching BS EN 50637:2017 Figure 201.102a
  • Compact, durable design for laboratory and production use
  • Reliable compliance with pediatric medical bed safety standards

Tell us your quantity, specific requirements or any customization needs โ€” our engineering team will reply with tailored recommendations within 24 hours.

Detail Display

Cone Tool for Medical Beds FAQs

What is the purpose of the cone tool for medical beds?
The cone tool for medical beds is used to verify safety gaps and clearance dimensions in childrenโ€™s medical beds and similar pediatric equipment according to BS EN 50637:2017 Figure 201.102a, helping prevent entrapment hazards.
Which standard does the cone tool for medical beds comply with?
The tool is manufactured exactly to BS EN 50637:2017 Figure 201.102a for safety testing of childrenโ€™s medical beds.
What is the weight specification of the cone tool for medical beds?
The cone tool for medical beds has a precisely controlled weight of 3.3 ยฑ 0.05 kg, ensuring repeatable and traceable test results.
What is the surface roughness of the cone tool for medical beds?
The surface roughness is maintained at 1.6 ฮผm to simulate realistic contact conditions as required by the standard.
What material is the cone tool for medical beds made of?
The tool is made of high-quality stainless steel, providing excellent corrosion resistance and long-term durability.
Is the cone tool for medical beds suitable for production line testing?
Yes. Its compact design, precise weight tolerance and durable construction make it ideal for both laboratory certification and routine production quality control.
How should the cone tool for medical beds be maintained?
Regular inspection of surface roughness and weight, combined with cleaning after each use, ensures continued accuracy and compliance with BS EN 50637:2017.
Can the cone tool for medical beds be customized?
Yes. We support minor customizations such as engraving or special packaging upon request. Please share your specific needs and we will provide a tailored solution.
How can I request a quotation for the cone tool for medical beds?
Contact our engineering team with your quantity or any special requirements. We will provide a competitive quote within 24 hours.
What is the delivery time for the cone tool for medical beds?
Standard delivery is 7 working days after order confirmation, with expedited options available upon request.

Related Products

Related News

Salt fog and salt spray test differ in exposure method and aggressiveness. Salt spray test offers rapid, direct corrosion assessment for quality control.
A Video Signal Generator creates test patterns to check display quality, color accuracy, and compliance, ensuring reliable video system performance.
Ensure ISO 14117 compliance for AIMDs by using a Defibrillation Test Pulse Generator to meet safety standards and document reliable defibrillation immunity testing.
Ensure IEC 60601 compliance in 2026 with Defib-proof and Energy Reduction Tester for safer, faster medical device approval and reliable patient protection.

ISO 5356-1:2015 is the internationally recognized standard titled Anaesthetic and respiratory equipment โ€” Conical connectors โ€” Part 1: Cones and […]

Shan Chao 1 , Qiang Xiaolong 2 , Liu jiming 3 , Zhang Chao 3 . (1. Heilongjiang Institute for […]

Abstract Thermage, a non-invasive radiofrequency (RF) skin tightening technology, is widely used in medical aesthetics. With operating frequencies increasing to […]

Dynamic Compensation Implementation for High-Frequency Electrosurgical Unit Testing Using High-Frequency LCR or Network Analyzers Above MHz Shan Chao1, Qiang Xiaolong2, […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.