IEC 62368-1 Clause 9.6 Wireless Power Receiver for FOD Temperature Rise Testing
The KP-368W is an IEC 62368-1 Clause 9.6 wireless power receiver used for wireless power transmitter FOD temperature rise testing. It provides receiver/load simulation for evaluating metallic foreign object heating under defined receiver positions and power levels.
It is suitable for safety laboratories, certification preparation, R&D verification and wireless charger manufacturers requiring repeatable IEC 62368-1 test conditions.
-
- Applicable Standard: IEC 62368-1 Clause 9.6
- Test Type: FOD temperature rise test
- Function: Wireless power receiver and load simulator
- Test Conditions: No receiver, contact, 2 mm and 5 mm spacing
Power Levels: 15 W, 10 W, 7.5 W, 5 W and external load - Input Range: 4.5–9 V, 0–3 A
Impedance Range: 1.5 Ω–9999.9 Ω - Recognition Mode: QC2.0 / QC3.0
- Typical DUT: Wireless power transmitters and wireless chargers
Product Overview
In IEC 62368-1 Clause 9.6 testing, the wireless power transmitter is the DUT, while the KP-368W works as the receiver/load-side device. It helps create controlled receiver-side operating conditions so engineers can evaluate how the transmitter responds when metallic foreign objects are placed on or near the charging surface.
The receiver condition is important because foreign object heating behavior may change when the receiver is absent, in direct contact with the object, or separated by defined distances such as 2 mm or 5 mm. By selecting the required power level and load condition, the KP-368W supports repeatable comparison during R&D testing, pre-compliance evaluation and laboratory verification.
This product should be used together with the required foreign metallic objects, spacing accessories and temperature measurement instruments according to the applicable IEC 62368-1 edition and laboratory test procedure.
Technical Specifications
Main specifications are organized below for quick laboratory and purchasing review.
| Model | KP-368W |
| Applicable Standard | IEC 62368-1 Edition 3, Clause 9.6 |
| Usage | Wireless charge / wireless power transmitter FOD temperature rise testing |
| Input Voltage | 4.5–9 V |
| Voltage Resolution | 0.01 V |
| Voltage Accuracy | ±(0.2% + 1 digit) |
| Input Current | 0–3 A |
| Current Resolution | 0.001 A |
| Current Accuracy | ±(0.8% + 3 digits) |
| Impedance Range | 1.5 Ω–9999.9 Ω |
| Temperature Range | -10℃ to 100℃ |
| Time Range | 0–99H59M59S |
| Frequency | 2 Hz |
| Recognition Mode | QC2.0 / QC3.0 |
| Power Levels | 15 W / 10 W / 7.5 W / 5 W / external loads |
| Weight | 118 g |
Specifications are based on the KP-368W configuration. Please confirm the applicable standard edition, transmitter power rating, receiver condition and accessory requirements before quotation.

What This Wireless Power Receiver Does in the Test Setup
Receiver and Load Simulation
The KP-368W works as the receiver/load-side device in the IEC 62368-1 Clause 9.6 test setup, helping engineers create repeatable receiver-side operating conditions.
Power and Load Configuration
The device supports 15 W, 10 W, 7.5 W, 5 W and external load conditions for wireless power transmitter evaluation under different rated power requirements.
Receiver Position Support
It can be used for test arrangements involving no receiver, receiver contact, 2 mm spacing and 5 mm spacing conditions, depending on the laboratory procedure.
QC Recognition and Monitoring Reference
QC2.0 / QC3.0 recognition, temperature range and time reference functions help support wireless charging behavior checks during R&D and pre-compliance evaluation.
IEC 62368-1 Clause 9.6 Test Arrangement
In a typical IEC 62368-1 Clause 9.6 wireless power transmitter test, the transmitter is evaluated with metallic foreign objects and receiver positions. The transmitter is normally operated at the required test power condition while the temperature of foreign objects is monitored.
Foreign Object Without Receiver
A metallic foreign object is placed on the transmitter without the receiver. This condition checks whether the transmitter can detect the object or prevent unsafe heating when no valid receiver is present.
Receiver in Direct Contact
The receiver is placed in direct contact with the foreign object. This arrangement evaluates the heating behavior when the receiver and foreign object are close together on the charging surface.
Receiver Positioned 2 mm Away
The receiver is positioned 2 mm from the metallic foreign object. This condition simulates a small separation between the receiver and the object during wireless power transfer.
Receiver Positioned 5 mm Away
The receiver is positioned 5 mm from the foreign object. This condition helps evaluate whether unsafe temperature rise may still occur under a larger separation distance.
The transmitter should be operated under the required test power condition according to the applicable standard edition and laboratory test plan.
Why IEC 62368-1 Clause 9.6 Testing Is Required
IEC 62368-1 Clause 9.6 focuses on the safety risks associated with wireless power transmitters. During wireless charging, metallic foreign objects placed on or near the charging surface may be heated by the electromagnetic field. The test helps evaluate whether the transmitter can control this heating risk under defined receiver and foreign object conditions.
Metallic Foreign Object Heating Risk
Coins, rings, keys, metal foils or other conductive objects may be accidentally placed on the charging surface and become heated if power transfer is not properly controlled.
FOD and Power Control Verification
The test helps check whether the transmitter can identify abnormal foreign object conditions, reduce output power, stop power transfer or limit unsafe temperature rise.
Receiver Position Conditions
Different receiver positions, including no receiver, direct contact, 2 mm spacing and 5 mm spacing, help evaluate heating behavior under foreseeable use scenarios.
Compliance Preparation
Manufacturers can use this test during product development, FOD adjustment and pre-compliance verification before formal certification testing.

Typical Applications
Certification Laboratory Testing
Used as receiver/load-side equipment for IEC 62368-1 Clause 9.6 wireless power transmitter test arrangements.
Manufacturer R&D Verification
Supports wireless charger development, FOD response checking, load behavior verification and pre-compliance preparation.
FOD Function Evaluation
Helps evaluate metallic foreign object heating behavior when the receiver is absent, in contact, or positioned at defined spacing distances.
Wireless Charger Safety Assessment
Suitable for wireless power transmitters, wireless chargers and ICT/AV products with wireless charging functions.
Difference from Related FOD Test Equipment
The KP-368W should be understood as the receiver/load-side device in the IEC 62368-1 Clause 9.6 wireless power transmitter test setup. A complete FOD temperature rise test may also require metallic foreign objects, spacing accessories and temperature measurement instruments.
KP-368W Wireless Power Receiver
Provides receiver/load simulation for checking wireless transmitter behavior under Clause 9.6 test conditions.
Foreign Metallic Objects
Simulate conductive objects such as steel disk, aluminium ring or aluminium foil that may be heated by the transmitter.
Spacers for Receiver Positioning
Used to control receiver distance from the foreign object, such as 2 mm and 5 mm spacing conditions.
Temperature Measurement Accessories
Thermocouples, thermometers or data loggers may be required to monitor temperature rise during the FOD test.

Configuration Notes Before Quotation
IEC 62368-1 Clause 9.6 testing may require different accessories depending on the product under test and the laboratory procedure. To recommend the correct configuration, please confirm the following information before quotation.
| Information to Confirm | Why It Matters |
|---|---|
| Applicable standard edition | Confirms whether the test plan follows the required IEC 62368-1 version and Clause 9.6 interpretation. |
| Wireless transmitter rated power | Determines the suitable receiver/load condition and required power level. |
| Required receiver arrangement | Confirms whether no receiver, contact, 2 mm spacing or 5 mm spacing conditions are needed. |
| Foreign metallic objects | Confirms whether steel disk, aluminium ring, aluminium foil or other defined objects are required. |
| Temperature measurement method | Confirms whether thermocouple, thermometer, data logger or an existing lab system will be used. |
| Documentation requirement | Helps prepare product specification, inspection record or calibration-related support if required. |
Compliance & Regulatory Assurance
- The KP-368W is designed for IEC 62368-1 Clause 9.6 wireless power transmitter FOD temperature rise testing. It helps laboratories and manufacturers verify receiver/load conditions, foreign object heating behavior and wireless charging safety performance during R&D, pre-compliance and laboratory evaluation.
- Before ordering, the applicable standard edition, transmitter power rating, receiver arrangement, foreign object type, temperature measurement method and documentation requirements should be confirmed. Technical datasheets and configuration support can be provided according to project needs.
IEC 62368-1 Clause 9.6 Wireless Power Receiver Datasheet
KP-368W datasheet with FOD temperature rise test setup, receiver/load simulation details, technical specifications and IEC 62368-1 Clause 9.6 configuration notes.
Technical Inquiry & Expert Support
KingPo supplies the KP-368W Wireless Power Receiver for IEC 62368-1 Clause 9.6 FOD temperature rise testing. Our engineering team can help confirm whether the receiver/load setup, power level and accessories match your test requirement.
Please Provide the Following Information
IEC 62368-1 Clause 9.6
Wireless power transmitter or wireless charger
FOD temperature rise evaluation
15 W, 10 W, 7.5 W, 5 W or external load
No receiver, contact, 2 mm spacing or 5 mm spacing
Steel disk, aluminium ring, aluminium foil or specified metallic object
Thermocouple, thermometer or data logger
Required quantity, delivery schedule and quotation deadline
Based on this information, KingPo can provide configuration confirmation, documentation support and quotation for your IEC 62368-1 Clause 9.6 wireless power transmitter FOD temperature rise test setup.
IEC 62368-1 Clause 9.6 Wireless Power Receiver
FAQ
Related Products
Related News
Quick Answer Leakage current testing devices are used to measure unintended current that may flow from live parts, insulation systems, […]
Abstract & Technical Summary IEC 62368-1 foreign object detection (FOD) testing assesses wireless power transmitter safeguards against excessive metal object […]