


IEC 60335-2-3 Clause 5.9 Test Iron
The IEC 60335-2-3 Clause 5.9 Test Iron is a standard test iron used to provide defined general test conditions for electric iron testing. It is designed with a weight of 1300 g ± 50 g, a soleplate area of 200 cm² ± 10%, and a soleplate temperature of 250 °C ± 10 °C.
- Designed for IEC 60335-2-3 Clause 5.9 general test conditions
- Used for electric iron testing and laboratory test preparation
- Iron weight: 1300 g ± 50 g
- Soleplate area: 200 cm² ± 10%
- Soleplate temperature: 250 °C ± 10 °C
- Provides repeatable heating and contact conditions during testing
- Electric heating structure for soleplate temperature control
- Wooden handle for manual handling during test preparation
- Suitable for appliance manufacturers, testing laboratories and QC departments
- Product specification and inspection support available according to order requirement
IEC 60335-2-3 Clause 5.9 Test Iron Overview
The IEC 60335-2-3 Clause 5.9 Test Iron is used when electric iron test procedures require a defined iron mass, soleplate area and soleplate temperature. It helps laboratories avoid variation caused by ordinary household irons with inconsistent weight, contact area or heating performance.
This product is intended for IEC 60335-2-3 related electric iron testing, product development verification, quality control inspection and certification preparation. Its standardized physical and thermal conditions support repeatable test setup and clearer documentation.
Applicable Standard and Test Method
The test iron is designed for IEC 60335-2-3 Clause 5.9 related general conditions for the tests. It is used when the test procedure requires an iron having specified weight, soleplate area and soleplate temperature.
During testing, the iron should be prepared according to the applicable IEC 60335-2-3 test clause and laboratory procedure. The soleplate temperature, contact position, test duration, sample condition and post-test evaluation should follow the relevant standard requirement.
The final compliance result depends on the complete test setup, tested product, operating condition, temperature verification, test method and acceptance criteria defined by the applicable standard.
Technical Parameters
Standard and Product Information
| Parameter | Specification | Remark or Notes |
|---|---|---|
| Product name | IEC 60335-2-3 Clause 5.9 Test Iron | Standard test iron for electric iron testing |
| Applicable standard | IEC 60335-2-3 Clause 5.9 | General conditions for the tests |
| Product type | Electric test iron | Standard test accessory |
| Test object | Electric irons and related appliance test setups | Confirm according to the applicable test clause |
| Test purpose | General test condition support | Used for standard-based electric iron testing |
| Iron weight | 1300 g ± 50 g | According to IEC 60335-2-3 Clause 5.9 requirement |
| Soleplate area | 200 cm² ± 10% | Contact area for test condition preparation |
| Soleplate temperature | 250 °C ± 10 °C | Temperature condition for applicable test setup |
| Handle type | Wooden handle | For manual handling during preparation |
| Typical users | Appliance manufacturers, testing laboratories and QC departments | For compliance preparation and routine verification |
Ordering and Use Information
| Parameter | Specification | Remark or Notes |
| Application field | Electric iron testing | IEC 60335-2-3 related test procedure |
| Use stage | R&D verification, type testing preparation and laboratory testing | According to customer test plan |
| Heating function | Electric heating structure | For maintaining required soleplate temperature |
| Documentation | Product specification and inspection support available | According to order requirement |
| Packaging | Safety carton pack or plywood box | Confirm according to shipment requirement |
| Quantity | 1 set or according to project requirement | Confirm before quotation |
Testing Principle and Result Evaluation
The IEC 60335-2-3 Clause 5.9 Test Iron provides a defined heating and contact condition for electric iron testing. Before testing, the iron weight, soleplate area and soleplate temperature should be confirmed, and the soleplate should be stabilized at 250 °C ± 10 °C.
During testing, the heated test iron is applied to the specified position according to the relevant IEC 60335-2-3 test procedure. The contact method, test duration, sample condition and observation items should follow the applicable clause.
The result is normally acceptable when the tested sample shows no unsafe condition such as ignition, hazardous deformation, insulation failure, exposed live parts or safety-related functional failure. If burning, melting, abnormal damage or other non-compliance occurs, the result should be evaluated according to the relevant standard clause and laboratory acceptance criteria.
Common Error Mitigation
Reliable electric iron testing depends on the complete test procedure, not only the test iron itself. Incorrect temperature control, unstable placement or use of an iron outside the specified mass range may affect test repeatability.
To reduce test variation, laboratories should avoid the following issues:
- Using a non-standard commercial iron instead of the specified test iron
- Testing before the soleplate temperature is stable
- Ignoring the 1300 g ± 50 g weight requirement
- Using an iron with unsuitable or damaged soleplate surface
- Applying the iron at an incorrect position or angle
- Failing to verify temperature before the test
- Recording results without following the applicable acceptance criteria
Applications and Use Cases

The IEC 60335-2-3 Clause 5.9 Test Iron is used in appliance safety laboratories and production quality control environments for electric iron testing.
Typical applications include:
- General test condition preparation for IEC 60335-2-3 Clause 5.9
- Electric iron safety testing and verification
- Product development validation and certification preparation
- Production quality control for electric iron products
- Third-party laboratory test setup and documentation support
Operation and Test Notes
Before testing, users should confirm the applicable IEC 60335-2-3 clause, required iron weight, soleplate area, soleplate temperature, test duration and sample condition. The test iron should be clean, stable and suitable for the intended test procedure.
The soleplate temperature should be verified according to the laboratory procedure before formal testing. The iron should be handled carefully during heating and test operation to avoid accidental burns, unstable placement or incorrect contact with the test sample.
Maintenance and Documentation Support
After testing, the iron should be allowed to cool down safely and stored in a dry, protected condition. The soleplate surface, power cord, handle and temperature control structure should be inspected regularly for damage, looseness, contamination or abnormal heating behavior.
For formal testing, laboratories should keep relevant records such as product specification, weight verification record, soleplate temperature verification record, inspection record and test result. KingPo can provide product documentation support according to order requirements.
Standards Compliance Notes
This product is intended to support testing according to IEC 60335-2-3 Clause 5.9 for electric irons. The specified test conditions include an iron weight of 1300 g ± 50 g, a soleplate area of 200 cm² ± 10%, and a soleplate temperature of 250 °C ± 10 °C.
The final compliance result depends on the tested product, test setup, temperature verification, contact condition, test duration, operation procedure and post-test evaluation. The test iron itself should not be described as independently certified equipment unless a specific calibration certificate or inspection document is provided.
Download IEC 60335-2-3 Clause 5.9 Test Iron Product Catalog
Download the KINGPO product catalog for the IEC 60335-2-3 Clause 5.9 test iron, including product information, application notes and configuration reference details for electric iron testing.
Technical Inquiry and Configuration Support
KingPo supplies the IEC 60335-2-3 Clause 5.9 Test Iron for electric iron testing and laboratory test preparation. Our engineering team can help confirm whether the test iron configuration matches your IEC 60335-2-3 test requirement and laboratory procedure.
Please Provide the Following Information:
- Applicable standard: IEC 60335-2-3 Clause 5.9 or internal laboratory test procedure
- Test object: Electric iron or related appliance test setup
- Test requirement: General conditions for the tests, temperature verification or compliance preparation
- Required iron weight: 1300 g ± 50 g or other project requirement
- Required soleplate area: 200 cm² ± 10% or customer-specific requirement
- Required soleplate temperature: 250 °C ± 10 °C or other specified condition
- Documentation requirement: Product specification, inspection record or calibration support
- Quantity requirement: Number of test irons required
- Project timeline: Required delivery schedule and quotation deadline
Based on this information, KingPo can provide product confirmation, documentation support and quotation for your IEC 60335-2-3 Clause 5.9 Test Iron requirement.
IEC 60335-2-3 Clause 5.9 Test Iron
IEC 60335-2-3 Clause 5.9 Test Iron FAQs
Related Products
Related News
KingPo supplied an IEC 60335-1 Clause 19 Battery Short Circuit Tester to TSK Corporation for a laboratory project in South […]
KingPo Eurofins IEC 60335 Test Equipment Delivered to Finland Espoo, Finland — Jun 2023 —A complete set of high-precision IEC 60335 […]
KingPo HCT IEC 60335 Test Equipment Delivered to Korea Seoul, Korea — Jun 2021 — High-precision KingPo HCT IEC 60335 test […]
KingPo Delivers IEC 60335 Test Equipment to Intertek Hong Kong and Korea Hong Kong & Seoul, March 2023 — KingPo […]
KingPo UL Vietnam IEC 60335 Test Equipment Delivered for IEC 62368-1 Compliance Hai Duong Province, Vietnam — KingPo is […]
As service robots (Service Robots) are increasingly deployed in commercial, public, and healthcare environments, human-robot interaction safety, mobility-related hazards, and […]