UL 2580 Clause 26 Short Circuit Tester with 2000A high-current circuit and temperature chamber for lithium battery external short circuit testing.
Open chamber view of the UL 2580 Clause 26 Short Circuit Tester showing the battery short circuit test setup inside the temperature controlled chamber.
Interior view of the UL 2580 Clause 26 Short Circuit Tester showing battery wiring fixtures and test connections for external short circuit testing.
UL 2580 Clause 26 Short Circuit Tester with 2000A high-current circuit and temperature chamber for lithium battery external short circuit testing.
Open chamber view of the UL 2580 Clause 26 Short Circuit Tester showing the battery short circuit test setup inside the temperature controlled chamber.
Interior view of the UL 2580 Clause 26 Short Circuit Tester showing battery wiring fixtures and test connections for external short circuit testing.

UL 2580 Clause 26 Short Circuit Tester

The UL 2580 Clause 26 Short Circuit Tester is a temperature controlled external short circuit testing system for lithium battery and battery pack safety evaluation. It provides high-current short circuit capability up to 2000A, chamber temperature control, current / voltage / temperature monitoring and safety protection structures for battery abuse testing under defined laboratory conditions.

  • Designed for UL 2580 Clause 26 external short circuit testing
  • High-current short circuit capability up to 2000A DC
  • Fast DC response time of ≤5μs
  • Temperature controlled chamber from RT+10℃ to 100℃
  • PLC control with touch screen operation
  • Current, voltage and temperature monitoring
  • Built-in short circuit resistor configuration for different test requirements
  • Reinforced chamber door with explosion-proof lock structure
  • Pressure relief system and smoke exhaust design
  • Double-layer tempered glass viewing window
  • USB data export in CSV format

UL 2580 Clause 26 Short Circuit Tester Overview

UL 2580 Clause 26 Short Circuit Tester

The UL 2580 Clause 26 Short Circuit Tester is used to simulate an external short circuit condition for lithium batteries and battery packs under controlled temperature conditions. During testing, the battery sample is placed inside the chamber and connected to the external short circuit circuit while key test data are monitored.

This equipment is suitable for battery manufacturers, EV battery laboratories, third-party testing institutions, R&D centers and quality control departments that need to evaluate battery behavior under high-current short circuit conditions.

The system supports repeatable battery abuse testing by combining short circuit control, chamber conditioning, safety protection and test record support in one integrated test platform.

Test Performance and Chamber Specifications

Parameter Specification Remark or Notes
Product name UL 2580 Clause 26 Short Circuit Tester Temperature controlled external short circuit tester
Model number SN551-2000A Original model from product page
Applicable standard UL 2580 Clause 26 External short circuit test application
Test object Lithium batteries and battery packs Confirm sample voltage, capacity and size before ordering
Maximum load current 2000A DC High-current short circuit capability
DC response time ≤5μs Fast short circuit response
Built-in resistor 20±0.2mΩ / 20±5mΩ and 80±20mΩ listed Final resistor configuration should be confirmed before order
Chamber size W650 × D650 × H500 mm Internal test chamber dimensions
Temperature range RT+10℃ to 100℃ Presettable chamber temperature
Temperature rise rate 3±1℃/min According to original product information
Temperature uniformity ±2℃ According to original product information

Control, Safety and Documentation Information

Parameter Specification Remark or Notes
Control method PLC control with touch screen For parameter setting and operation
Data acquisition Current, voltage and temperature channels For test monitoring and record keeping
Current range 0–2000A DC 1 current channel
Voltage range 0–100V DC 1 voltage channel
Battery surface temperature range -20℃ to 1000℃ 1 surface temperature channel
Data rate 1 sample / second For all channels
Sample rack SUS #201 perforated steel, 30 kg per layer Adjustable height
Safety design Reinforced door, pressure relief, smoke exhaust and observation window For battery abuse testing safety support
External dimensions Approx. W900 × D850 × H1500 mm Overall equipment size
Weight Approx. 300 kg Installation floor load should be confirmed
Power supply AC 220V, 50/60Hz, 3kW Confirm local power supply before order
Certification support Calibration Certificate available Cost additional according to original product page
Packaging Plywood case For export shipment

Testing Principle and Result Evaluation

Lab technician preparing the UL 2580 Clause 26 Short Circuit Tester for a 2000A lithium battery external short circuit test in a temperature-controlled chamber.
UL 2580 Clause 26 Short Circuit Tester

The UL 2580 Clause 26 Short Circuit Tester creates a controlled external short circuit condition for lithium batteries or battery packs. The battery sample is placed inside the temperature controlled chamber, and the short circuit circuit is configured according to the required test condition, chamber temperature, resistor configuration and termination setting.

1. Test Setup

Confirm sample information, chamber temperature, resistor configuration, cable connection, sensor position and termination condition.

2. Short Circuit Test

The external short circuit condition is applied while current, voltage, chamber temperature and battery surface temperature are monitored.

3. Result Review

Evaluate voltage drop, current change, temperature rise, smoke, venting, rupture, fire or other abnormal reactions.

Result Evaluation Reference

The test may be stopped when the preset short circuit time is reached or when the battery temperature drops according to the defined test condition. The equipment provides the required test condition and data acquisition support, while final evaluation should follow the applicable standard and laboratory procedure.

Common Error Mitigation

Reliable external short circuit testing depends on correct test setup, safe installation and accurate data recording. Laboratories should avoid the following issues:

●Selecting the tester only by maximum current without confirming sample voltage and capacity ● Ignoring the required short circuit resistance specified by the test standard
● Not confirming whether the resistor configuration matches the actual test requirement ● Using undersized cables or unsuitable battery connection fixtures
● Running the test without proper ventilation and smoke exhaust preparation ● Opening the chamber before the required observation period is complete
● Recording only final results without saving current, voltage and temperature data ● Treating the equipment certificate as a battery product certification certificate

Installation and Laboratory Safety Notes

Battery external short circuit testing is a high-risk abuse test. The equipment should be installed in a ventilated laboratory with smoke exhaust, emergency access, fire protection equipment and operator safety procedures.

Installation Check:Confirm floor load, equipment clearance, grounding, power supply, exhaust connection and safe operating space. Operator Safety:Confirm emergency stop function, test area control, PPE requirements and internal laboratory emergency procedures. Abuse Test Risk:Battery samples may release smoke, heat, gas, flame or debris under abuse conditions.

Maintenance and Documentation Support

Maintenance Inspection:After testing, the chamber should be inspected for smoke contamination, residue, corrosion, cable damage or fixture wear. The observation window, sealing strip, pressure relief device, exhaust port, sample rack and connection terminals should be checked regularly. Recommended Documentation:Formal laboratory use should keep equipment specification, calibration certificate, resistor verification record, acquisition record, setup photo, sample information, test condition, abnormal condition observation and final test report.

Documentation Support

Calibration Certificate support is available. Users should confirm whether certification, inspection records, resistor verification or additional documentation are required before order.

Standards Compliance Notes

This tester is designed to support UL 2580 Clause 26 external short circuit testing for lithium batteries and battery packs. It may also be configured for related battery short circuit test requirements depending on the applicable standard, sample type, resistor condition, temperature condition and laboratory procedure.

Final compliance does not depend on the equipment alone. The test result should be evaluated based on the official standard, sample preparation, test setup, short circuit resistance, chamber temperature, observation period, recorded data and laboratory acceptance criteria.

The equipment should be described as a test system for supporting UL 2580 Clause 26 testing, not as a product certification result. If a calibration certificate is required, the certificate scope and covered parameters should be confirmed before ordering.

Technical Inquiry & Configuration Support

Before requesting a quotation, customers are recommended to provide the following information:

  • Applicable standard: UL 2580 Clause 26 or other battery safety standard
  • Battery type: cell, module or battery pack
  • Battery voltage and capacity
  • Maximum expected short circuit current
  • Required short circuit resistance
  • Required chamber temperature condition
  • Sample size and weight
  • Data acquisition requirements
  • Required certificate or calibration document
  • Local power supply
  • Laboratory ventilation and exhaust conditions
  • Required delivery time and installation support

Based on this information, Kingpo can confirm whether the SN551-2000A UL 2580 Clause 26 Short Circuit Tester is suitable for the customer’s test requirement.

UL 2580 Clause 26 Short Circuit Tester

UL 2580 Clause 26 Short Circuit Tester FAQs

What is the UL 2580 Clause 26 Short Circuit Tester used for?
It is used to perform temperature controlled external short circuit testing for lithium batteries and battery packs. The tester provides high-current short circuit capability, chamber temperature control and data acquisition for battery safety evaluation.
What is the maximum current of this tester?
The maximum load current is 2000A DC. The actual test current depends on the battery sample, battery voltage, internal resistance, short circuit resistance and test setup.
What is the DC response time?
The DC response time is listed as ≤5μs, which supports fast formation of the short circuit condition during battery abuse testing.
What temperature range does the chamber support?
The chamber temperature control range is RT+10℃ to 100℃, with a listed temperature rise rate of 3±1℃/min and temperature uniformity of ±2℃.
What data can be recorded during testing?
The system can record short circuit current, battery voltage, chamber temperature and battery surface temperature. These values help laboratories evaluate battery behavior during the short circuit test.
Does the tester include safety protection?
Yes. The system includes reinforced chamber structure, explosion-proof door lock design, pressure relief system, smoke exhaust system and tempered glass observation window.
Can test data be exported?
Yes. The control system supports USB data export in CSV format, which is useful for laboratory records and report preparation.
Is a calibration certificate available?
A calibration certificate is available at additional cost according to the original product information. Customers should confirm the certificate scope before ordering.
Why should the resistor configuration be confirmed before ordering?
The original product page lists different resistor information in different sections, so the final resistor configuration should be confirmed according to the required standard and test condition before quotation.
What should customers confirm before ordering?
Customers should confirm the applicable standard, battery voltage, capacity, sample size, expected short circuit current, required resistance, chamber temperature condition, documentation requirement, local power supply and installation environment.

Related Products

Related News

KingPo supplied ISO 80369-7 Luer Gauges to Angiosistemy LLC in Russia. The gauges are used for laboratory testing of medical […]

KingPo supplied an IEC 60335-1 Clause 19 Battery Short Circuit Tester to TSK Corporation for a laboratory project in South […]

KP-1230S dielectric strength tester specs deliver advanced safety, compliance, and reliability for medical device testing, meeting ISO 27186:2020 standards.

Abstract & Technical Summary Under the UK’s BS 7671 IET Wiring Regulations (18th Edition), electrical safety and circuit protection rely […]

IPX9K represents one of the highest levels of water ingress protection in the IEC 60529 and ISO 20653 standards. It […]

For plastic insulation frames, given the high heat generated by the copper wires and iron core, if the flame retardant […]

IEC 62368-1 safety standard transition: key compliance steps, UL 62368-1 differences, and what manufacturers must do for global market access.

Technical Insight for IEC 60601-2-2 High-Frequency Surgical Equipment Testing High-frequency electrosurgical units (ESU) operate in the radio frequency range above […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.