Geometric Fit Testing of In-ear Headphones (IEMs) using HF HATS Artificial Ear Canal Simulator
Detailed view of Built-in Realistic Artificial Ear and Mouth Simulators on HF HATS Type AD8320
HF HATS AD8320 Testing Smartphone Audio Performance and Smart Speaker Directivity in Laboratory
Geometric Fit Testing of In-ear Headphones (IEMs) using HF HATS Artificial Ear Canal Simulator
Detailed view of Built-in Realistic Artificial Ear and Mouth Simulators on HF HATS Type AD8320
HF HATS AD8320 Testing Smartphone Audio Performance and Smart Speaker Directivity in Laboratory

High Frequency Head and Torso Simulator HF HATS AD8320 โ€“ KingPo Electroacoustic Testing for Smart Devices and Headphones

HF HATS AD8320 provides unprecedented realism for electroacoustic testing of smart devices, microphones, and headphones. Featuring built-in realistic ear and mouth simulators, it covers the full audible range up to 20 kHz in compliance with ITU-T P.58 and IEC 60318-1.

  • Standard Compliance: Fully meets IEC 60318-1:2009 and ITU-T Rec.P.58 international standards

  • Frequency Range: Covers full audible spectrum from 20Hz to 20kHz for high-fidelity analysis

  • Acoustic Realism: Mathematical modeling of human head, shoulders, artificial mouth, and dual ears

  • High Dynamic Range: โ‰ฅ160dB with equivalent noise โ‰ค17dB for ultra-quiet laboratory testing

  • MOQ: 1 unit

  • Price: To be quoted

  • Standard Packaging: Specialized protective flight case for high-precision instruments

  • Delivery Period: 20โ€“30 days

  • Payment Method: T/T

  • Supply Capacity: 10 units/month

High Frequency Head and Torso Simulator

High Frequency Head and Torso Simulator (HF HATS) for Smart Device Testing

The High-frequency Head and Torso Simulator (HF HATS) Type AD8320 family is an advanced electroacoustic research tool that provides an unprecedented reproduction of human acoustic properties. Designed for in situ electroacoustics tests, KingPoโ€™s HF HATS simulates the average adult human head and torso with integrated mouth and ear simulators. This allows for the realistic evaluation of audio performance in smartphones, conferencing devices, and high-end headphones across the entire audible frequency range (up to 20 kHz).

KingPo Factory Advantages

Based in Dongguan, KingPo (DG KingPo) is an ISO9001 certified manufacturer specializing in high-end electroacoustic simulation. The AD8320 HF HATS is engineered to meet the stringent demands of national and international communication standards. We provide factory-direct technical support, precision calibration reports, and custom ear canal geometries, helping R&D labs achieve the most accurate speech intelligibility and sound quality assessments at a competitive industrial price point.

Professional Construction & Technical Precision

Key technical features include:

  • Anatomical Accuracy โ€“ Features sophisticated mathematical modeling of the human head and shoulders to simulate realistic diffraction and reflection of sound waves.
  • Integrated Ear & Mouth Simulators โ€“ Dual artificial ears (IEC 60318-1 compliant) and a high-output artificial mouth for two-way communication testing.
  • Superior Dynamic Range โ€“ Boasts a dynamic range of โ‰ฅ160dB and a high sensitivity of -37dBV, allowing for the detection of even the most subtle acoustic artifacts.
  • Extended Frequency Response โ€“ Unlike standard simulators, the HF HATS supports testing up to 20kHz, crucial for modern high-resolution audio devices and sibilance evaluation.
  • Reliable Thermal Stability โ€“ Engineered with a low temperature coefficient of -0.005 dB/โ„ƒ, ensuring consistent data in varied laboratory environments.

Primary Use Cases & Business Value

The HF HATS AD8320 is the essential benchmark for:

  • Smartphone Performance โ€“ Testing mobile handsets against ITU-T and national communication quality standards.

  • Smart Speaker & AI Voice โ€“ Evaluating directivity, feedback suppression, and background noise cancellation in hands-free devices.

  • Headphone R&D โ€“ Identifying frequency response anomalies in over-ear and in-ear monitors (IEMs) using human-perceived quality metrics.

  • Hearing Aid Evaluation โ€“ Measuring sound quality and anatomical positioning for medical-grade hearing devices.

  • Hearing Protection โ€“ Testing the attenuation and sealing effectiveness of industrial ear protectors and safety gear.

Compliance & Regulatory Assurance

Fully compliant with IEC 60318-1:2009 (Electroacoustics โ€“ Simulators of human head and ear) and ITU-T Rec.P.58. It also meets GB/T 25498.1-2010 requirements, ensuring that your test data is globally recognized by certification bodies and regulatory agencies.

Procurement Benefits

Complete with a 1-year warranty and a precision-engineered structure (Mouth/Ear/Head/Shoulder). KingPoโ€™s AD8320 provides the geometric fit crucial for evaluating in-ear headphones and high-frequency communication devices. Contact KingPo today for a professional technical consultation and the best factory-direct quote on the HF HATS AD8320.

High Frequency HF HATS AD8320 Technical Specifications

Parameter Specification Details
Model Number AD8320 (High Frequency Series)
Reference Standards IEC 60318-1:2009 / ITU-T Rec.P.58 / GB/T 25498.1
Structure Human Head/Shoulder Model, Artificial Mouth, 2 Artificial Ears
Frequency Range (Mic) 20Hz โ€“ 20kHz
Frequency Range (Mouth) 100Hz โ€“ 8kHz
Dynamic Range โ‰ฅ 160 dB
Sensitivity -37 dBV (ยฑ1dB)
Total Harmonic Distortion < 1% (300Hz-10kHz @ 94dBSPL)
Max Sound Pressure Level 110 dB SPL @ 1V (0.25W)
Rated Resistance 4 ohm
Operating Temp Range -20โ„ƒ to +60โ„ƒ
Weight Approx. High-Stability Weighted Structure
Warranty 1 Year
Origin Dongguan, China (KingPo Manufacturer)

 

Get Free Quote of High Frequency Head And Torso Simulator Hf Hats For Smart Devices Speakers Electroacoustic Testing

KingPo provides the professional-grade High Frequency Head and Torso Simulator (HF HATS) direct from our factory, ensuring human-realistic audio testing for the next generation of smart devices.

Full Spectrum Realism โ€“ Full audible range up to 20kHz for high-resolution audio.

  • Global Standard Compliance โ€“ Fully aligned with ITU-T P.58 and IEC 60318-1.

  • Precision Simulation โ€“ Integrated ear and mouth simulators for two-way communication testing.

  • Factory Direct Pricing โ€“ High-end acoustic technology without the third-party markup.

  • Technical Support โ€“ 1-year warranty and lifetime assistance for electroacoustic setup.

Submit your inquiry now to receive a detailed technical catalog and pricing within 24 hours!

HF HATS Electroacoustic Applications

  • TWS & Hi-Fi Headphones โ€“ Frequency response and artifacts analysis for in-ear/over-ear designs.

  • Smart Speakers & Conference Phones โ€“ Directivity and speech intelligibility evaluation.

  • Hearing Aids & Medical โ€“ Anatomical sound quality assessment for hearing correction devices.

  • Hearing Protection โ€“ Measuring the sealing and attenuation of earplugs and muffs.

Technical Parameters

Structure Mathematical modeling of human head, mathematical modeling of human shoulder, artificial mouth, artificial ear 2
Referenceย Standard IEC 60318-1:2009 Electroacoustics โ€“ Simulators of human head and ear โ€“ Part 1 ITU-T Rec.P.58

GB / T 25498.1-2010 electric acoustic human head simulator and ear simulator

Frequency Ring Range 20Hz โ€“ 20kHz
Dynamic Range โ‰ฅ160dB
Equivalent Noise โ‰ค 17dB
Sensitivity -37dBV(ยฑ1dB)
Operating Temperature Range -20โ„ƒ – +60โ„ƒ
Temperature Coefficient -0.005 dB/โ„ƒ (@250 Hz)
Static Pressure Coefficient -0.007 dB/kPa
Continuous Output of The Sound Pressure Level 110dBSPL,@1V(0.25W)
Total Harmonic Distortion 200Hz-300Hz ๏ผœ2%,300Hz-10kHz ๏ผœ1%,@94dBSPL
Maximum Power 10W
Frequency Ring Range 100Hz โ€“ 8kHz
Rated Resistance 4ohm

High Frequency Head and Torso Simulator HF Detail Display

HF HATS Head and Torso Simulator FAQs

Does this simulator comply with ITU-T P.58?
Yes, the AD8320 fully complies with ITU-T Rec.P.58 and IEC 60318-1 for human head and ear simulation.
What is the maximum frequency range the AD8320 can test?
It supports the full audible frequency range up to 20 kHz, making it ideal for high-fidelity audio devices.
Are the ear simulators included with the HATS?
Yes, the AD8320 family includes built-in realistic ear simulators (dual ears) and a mouth simulator.
Can I test in-ear headphones with this model?
Absolutely. The new ear canal design provides the precise geometric fit required for designers of in-ear headphones.
What is the benefit of the high dynamic range (160dB)?
It allows for extremely accurate measurements of low-level signals and artifacts without interference from system noise.
Does the mouth simulator support directivity testing?
Yes, it is designed for accurate production of human speech to evaluate directivity and feedback in conference devices.
What is the sensitivity of the built-in microphones?
The sensitivity is rated at -37dBV (ยฑ1dB), ensuring high-precision capture of acoustic data.
Is the simulator affected by temperature changes in the lab?
It features a very low temperature coefficient of -0.005 dB/โ„ƒ, maintaining stability between -20โ„ƒ and +60โ„ƒ.
How is the product shipped for international orders?
We use a specialized protective flight case or reinforced plywood casing to ensure the delicate sensors are protected.
What after-sales service does KingPo offer?
We provide a 1-year warranty, factory calibration verification, and 24-hour technical support response.

Related Products

Related News

Compare KINGPO KP-1060 with top ESD generator and capacitor discharge testers to find the best option for safe, accurate capacitor discharge testing.
Manufacturers perform glow wire tests by heating a wire and applying it to electrical components to assess fire resistance and meet safety standards.

The glow wire test (GWT) is a cornerstone fire hazard assessment method in electrical and electronic product safety, as defined […]

External defibrillators are performanceโ€‘critical devices. For thirdโ€‘party calibration and certification laboratoriesโ€”and for manufacturersโ€™ QA/production teamsโ€”the โ€œmake or breakโ€ is whether […]

IP ratings explained: Understand each code, what the digits mean, and how to choose the right protection level for electronics in any environment.

Abstract Thermage, a non-invasive radiofrequency (RF) skin tightening technology, is widely used in medical aesthetics. With operating frequencies increasing to […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.