Front view of the SASO 1858 electric water heater test laboratory for performance and energy-related testing
Angled view of the SASO 1858 electric water heater test laboratory installed in a clean laboratory environment
Slightly elevated view of the SASO 1858 electric water heater test laboratory for energy efficiency and performance testing
SASO 1858 electric water heater test laboratory installed in an industrial laboratory environment
Front view of the SASO 1858 electric water heater test laboratory for performance and energy-related testing
Angled view of the SASO 1858 electric water heater test laboratory installed in a clean laboratory environment
Slightly elevated view of the SASO 1858 electric water heater test laboratory for energy efficiency and performance testing
SASO 1858 electric water heater test laboratory installed in an industrial laboratory environment

SASO 1858 Electric Water Heater Energy Efficiency Test Laboratory

The KINGPO six-station electric water heater test laboratory is designed for SASO 1858 performance and energy-related testing. It integrates environmental control, water conditioning, power supply, measurement, and data acquisition for controlled water heater testing.

  • Standards Focus: Developed for SASO 1858 electric water heater test projects, with applicable IEC 60379:2023 performance measurement methods considered according to the confirmed test scope.
  • Six-Station Testing: Dedicated configuration for installing and testing up to six household electric storage water heaters.
  • Integrated Test System: Combines environmental conditioning, water preparation, programmable electrical power, measurement, and data acquisition in one coordinated system.
  • Water-Side Measurement: Supports conditioned water supply, inlet and outlet temperature monitoring, and water flow measurement during testing.
  • Centralized Data Acquisition: Configured measurement channels are recorded through the integrated data system with an adjustable sampling period.
  • Typical Applications: Suitable for water heater manufacturers, R&D laboratories, internal performance verification, and third-party test projects.
  • Project Configuration: Final system details are reviewed according to heater capacity, electrical rating, required test items, and installation conditions.
  • Supply Scope: KINGPO supplies the integrated test equipment and systems; laboratory civil construction and room decoration are not included.

Product Overview

Performance testing of electric storage water heaters requires defined environmental, water, and electrical operating conditions. Changes in inlet water temperature, ambient conditions, water flow, or supply voltage can affect the operating behaviour and measured data of the test sample.

The KINGPO electric water heater test laboratory six-station water heater test laboratory integrates these test-related functions into one coordinated system. Six water heaters can be installed at dedicated test positions and connected to the conditioned water and electrical supply systems. Temperature and flow measurement channels monitor the configured test points, while the data acquisition system records test data for review and analysis.

The system is intended for household electric storage water heater performance and energy-related test projects, particularly in manufacturer laboratories, product development departments, engineering verification laboratories, and third-party testing facilities.

Technical Specifications

The main laboratory, environmental, water, electrical, and data-system specifications are organized below for quick technical and purchasing review.

Laboratory Configuration

Parameter Specification
Main Test Purpose Electric water heater performance and energy-related testing
Referenced Test Project SASO 1858
Performance Measurement Reference IEC 60379, according to the confirmed test scope
Test Object Household electric storage water heaters
Test Capacity 6 samples
Reference Laboratory Dimensions 6800 × 3800 × 3200 mm
Reference Door Size 2200 × 1200 mm
Test Station Arrangement 2 rows, 3 stations per row
Test Station Load Capacity 500 kg per station

Controlled Test Conditions

Parameter Specification
Laboratory Temperature Range 10°C to 50°C
Laboratory Humidity Range 40% to 85% RH
Humidity Stability ±3% RH
Air Velocity ≤0.25 m/s
Conditioned Water Temperature 10°C to 35°C
Constant-Temperature Water Tank 2000 L
Maximum Design Water Pressure 1.2 MPa
Water Flow Capability ≥20 L/min at 0.3 MPa

Electrical and Data System

Parameter Specification
Inverter Power Supplies 2 three-phase units
Rated Capacity 45 kVA per unit
Supply Voltage 230 V / 415 V
Adjustable Single-Phase Output 5–300 V
Adjustable Frequency 47–63 Hz
Data Sampling Period 5–60 seconds, configurable
Software Language Chinese / English

What This Water Heater Test Laboratory Measures

Energy Consumption and Thermal Retention

Supports 24-hour energy consumption coefficient testing, power consumption testing, and insulation or holding-time related evaluation within the referenced configuration.

Heating and Electrical Input Performance

Supports heating tests and input power experiments under controlled electrical operating conditions within the configured voltage and frequency range.

Hot Water Output and Water Consumption

Combines inlet and outlet water temperature measurement with water flow monitoring for hot water outlet rate and water consumption related test work.

Controlled Environmental Testing

Provides adjustable temperature and humidity conditions for configured high-temperature/high-humidity and low-temperature test applications.

Applicable Standards and Test Purpose

SASO 1858 Test Projects

This electric water heater test laboratory configuration was developed for SASO 1858 electric water heater test projects involving household storage-type electric water heaters.

Because standards and national market requirements may be revised, the required standard number, edition, destination market, and test items should be confirmed before the final technical configuration is approved.

IEC 60379 Performance Measurement Reference

IEC 60379:2023 specifies methods for measuring the performance of electric storage water heaters for household and similar purposes. Applicable performance measurement functions can be reviewed according to the confirmed project scope.

IEC 60379 addresses performance measurement rather than electrical appliance safety. Storage water heater safety testing should be considered separately according to the applicable IEC 60335 requirements.

How the Six-Station Electric Water Heater Test Laboratory Works

STEP 01

Test Environment Conditioning

Temperature and humidity are adjusted within the configured operating range using refrigeration, heating, humidification, and air-circulation functions.

STEP 02

Water Preparation

The 2000 L stainless steel tank stores and stirs the test water, with a configured water temperature range of 10°C to 35°C.

STEP 03

Sample Installation

Up to six electric storage water heaters are installed at dedicated test positions arranged in two rows with three stations per row.

STEP 04

Electrical Supply Control

The samples are connected to the inverter power system to establish defined voltage and frequency conditions within the equipment range.

STEP 05

Temperature and Flow Measurement

Configured channels monitor ambient conditions, mixed-water tank temperature, inlet/outlet water temperature, and water flow.

STEP 06

Data Acquisition and Review

Measurement signals are centrally recorded for storage, export, review, statistics, analysis, and printing, with a configurable 5–60 second sampling period.

Laboratory System Architecture

Controlled Test Environment System

The environmental control system provides adjustable temperature and humidity conditions for water heater performance testing. The referenced design includes water-cooled refrigeration, heating protection, automatic defrost, stainless steel humidification components, and automatic water-level protection.

Constant-Temperature Water Supply System

The 2000 L 304 stainless steel tank provides water storage and stirring for conditioned water preparation. The final water supply, pressure, drainage, and connection arrangement should be reviewed against the customer’s site conditions and required test procedure.

Programmable Electrical Power Supply

Two 45 kVA three-phase inverter power supplies are included in the referenced configuration. The system provides adjustable single-phase output from 5 V to 300 V and an adjustable frequency range of 47 Hz to 63 Hz.

Six Water Heater Test Stations

Six dedicated sample positions are arranged in two rows, with three stations per row. Each station uses a steel-frame support structure with adjustable stainless steel hooks and a referenced load capacity of 500 kg per station.

Measurement and Data Acquisition System

Measurement Parameter Sensor / Measuring Device Acquisition / Control Main Function
Ambient Temperature HMT100 temperature measurement point UT35A Environmental temperature monitoring
Ambient Humidity HMT100 humidity measurement point UT35A Relative humidity monitoring
Mixed Water Tank Temperature Pt100 Class A UT35A Conditioned water temperature monitoring
Inlet / Outlet Water Temperature Class I Type-T thermocouple GM10 Water temperature data acquisition
Water Flow Electromagnetic flowmeter GM10 Water flow measurement during testing

Final instrument models, measuring channels, system measurement accuracy, and calibration requirements should be confirmed in the approved technical configuration.

Test Control and Data Management Software

Software Function Description
Data Management Storage, export, review, statistics, analysis, and printing
Sampling Period Configurable from 5 to 60 seconds
Test Continuation Automatic test continuation after system restart in the referenced configuration
User Access Multi-user access function
Software Language Chinese and English

Why Controlled Water and Environmental Conditions Matter

Electric storage water heater performance can be influenced by inlet water temperature, ambient conditions, water flow, and electrical operating conditions.

For this reason, the test environment, water preparation system, power supply, and measurement channels need to operate under defined conditions throughout the selected test procedure. The KINGPO laboratory integrates these functions around six dedicated test positions to support a more controlled and organized test workflow.

Six-Station Test Capacity for Laboratory Workflows

The laboratory provides six dedicated test positions arranged in two rows. This configuration allows manufacturer and laboratory teams to organize multiple water heater samples or scheduled test projects within one dedicated test system.

Actual simultaneous test operation depends on the selected procedure, utility capacity, measuring channel arrangement, and laboratory test plan. The six-station specification represents the physical sample capacity of this laboratory configuration.

SASO 1858 electric water heater test laboratory installed in an industrial laboratory environment

Typical Test Objects

The laboratory is intended mainly for household electric storage water heaters within the confirmed project scope. Typical SASO 1858-related projects may involve household storage-closed type electric water heaters.

The exact sample type, rated storage capacity, dimensions, weight, and electrical characteristics should be reviewed before system configuration. Instantaneous, heat-pump, solar, or industrial water heating products should not be assumed to use the same test configuration without technical review.

Typical Laboratory Use Cases

Manufacturer R&D Laboratories

For controlled performance measurement and comparison of electric storage water heater samples during product development.

Internal Performance Verification

For internal product evaluation and engineering verification with continuous recording of configured temperature, flow, and operating data.

Quality and Engineering Laboratories

For teams that require a dedicated workflow combining environmental conditioning, water preparation, sample installation, and data acquisition.

Third-Party Test Projects

For electric storage water heater test projects within the confirmed standard, measurement, documentation, and calibration scope.

Scope of KINGPO Supply

  • Environmental conditioning equipment associated with the test system
  • Constant-temperature water preparation and supply system
  • Electrical power supply system
  • Six water heater test stations
  • Temperature and water flow measurement devices
  • Data acquisition hardware
  • Test control and data management software
  • Technical documentation according to the confirmed supply scope

Laboratory civil construction, building works, and room decoration are not included in the standard KINGPO equipment supply scope.

The final supply list is subject to the approved technical proposal and quotation. Site electrical utilities, water supply, drainage, installation access, and supporting conditions should be confirmed during project planning.

Site and Configuration Requirements

Laboratory Space

The referenced six-station layout uses a laboratory area of approximately 6800 × 3800 × 3200 mm. Actual room dimensions, entrance size, access route, and maintenance space should be reviewed before final arrangement.

Electrical Utility Conditions

Available site voltage, frequency, phase configuration, and electrical capacity should be confirmed together with the rated electrical characteristics of the water heater samples.

Water Supply and Drainage

Suitable water supply and drainage conditions are required. Water pressure, utility connection points, and drainage arrangement should be reviewed against the final laboratory layout.

Equipment Access and Maintenance

The layout should provide practical access to the six stations, water system, environmental equipment, inverter power supplies, and measuring components.

Technical Documentation and Measurement Support

KINGPO can provide system-related technical documentation according to the confirmed project and equipment supply scope. Documentation may include equipment configuration information, instrument details, operating instructions, and test system arrangement documents.

Calibration requirements for temperature, water flow, electrical measurement, and data acquisition channels should be confirmed according to the customer’s laboratory quality system and project requirements. Any specific third-party calibration or document-format requirement should be identified before the technical proposal is finalized.

Why Choose KINGPO for a Water Heater Test Laboratory Project?

Integrated Laboratory Test System

The laboratory combines environmental conditioning, water preparation, programmable electrical power, six sample positions, measurement channels, and centralized data acquisition around the water heater test process.

Water Heater Performance Test Configuration

The system architecture addresses water temperature, inlet and outlet conditions, water flow, electrical operation, and continuous test-data recording.

Dedicated Six-Station Capacity

The fixed 2 × 3 station arrangement provides a structured test area for multiple household electric storage water heater samples.

Technical Review Before Configuration

KINGPO reviews the required standard, test items, water heater specifications, electrical ratings, and site conditions before confirming the final technical solution.

Compliance & Regulatory Assurance

  • The six-station electric water heater test laboratory is developed for SASO 1858 electric water heater test projects and can support applicable IEC 60379 performance measurement functions according to the confirmed test scope. It is suitable for manufacturer laboratories, engineering verification, internal performance testing, and related third-party test projects.
  • To support standards-based testing, the required standard edition, water heater specification, test items, measurement channels, site conditions, and documentation requirements should be confirmed before final configuration. Calibration-related documentation and technical files can be prepared according to the agreed project scope.

SASO 1858 Electric Water Heater Test Laboratory Catalogue

Six-station electric water heater energy efficiency test laboratory catalogue with system configuration, technical specifications, measurement architecture and SASO 1858-related test application information.

Technical Inquiry & Expert Support

For an accurate laboratory configuration, please share the key project information below when sending an inquiry. This helps KINGPO review whether the six-station system matches your SASO 1858 test project, water heater specifications, utility conditions, and measurement scope before quotation

Information Needed Example
Applicable standard SASO 1858 / confirmed project standard and edition
Water heater type Household electric storage water heater
Storage capacity range Required sample capacity range
Electrical rating Rated voltage, frequency, and power
Sample information Maximum dimensions, weight, and mounting arrangement
Required test items Energy consumption, heating, hot water output, water consumption, or specified project tests
Laboratory site conditions Available room dimensions, electrical supply, water supply, and drainage
Measurement requirements Temperature, water flow, data acquisition, and documentation scope

KINGPO can review your test plan, sample specifications, and laboratory site conditions before quotation. This helps confirm the required measurement channels, water and power system configuration, test-station suitability, and project supply scope before the six-station laboratory solution is finalized.

Detail Display

FAQ

What is the Electric Water Heater Energy Efficiency Test Laboratory used for?
The laboratory is designed for performance and energy-related testing of household electric storage water heaters. It integrates controlled environmental conditions, conditioned water supply, electrical power, temperature and flow measurement, and centralized data acquisition to support defined laboratory test procedures and engineering evaluation.
Is the laboratory designed for SASO 1858 water heater testing?
The referenced six-station configuration was developed for SASO 1858-related electric water heater test projects. Because standard editions and market requirements may change, customers should confirm the applicable standard, edition, destination market, and required test items before the final technical configuration is approved.
How is IEC 60379 related to this water heater test laboratory?
IEC 60379 specifies performance measurement methods for electric storage water heaters for household and similar purposes. Applicable IEC 60379 measurement functions can be considered according to the confirmed project scope. Electrical safety testing is separate and should be evaluated according to the applicable IEC 60335 requirements.
How many electric water heaters can the system accommodate?
The laboratory provides six dedicated test positions arranged in two rows with three stations per row. This configuration allows laboratories to organize multiple samples within one integrated system. Actual simultaneous testing depends on the selected test procedure, utility capacity, measurement configuration, and laboratory operating plan.
What performance parameters can the test system monitor?
The referenced system includes measurement of ambient temperature, ambient humidity, conditioned water tank temperature, water heater inlet and outlet temperatures, and water flow. Test data are collected through the configured acquisition system. Final measuring channels and electrical parameters should be confirmed according to the required test items.
What types of electric water heaters are suitable for this laboratory?
The laboratory is mainly intended for household electric storage water heaters within the confirmed project scope. Customers should provide the sample type, rated storage capacity, dimensions, weight, voltage, frequency, and rated power. Instantaneous, heat-pump, solar, or industrial water heaters require separate technical evaluation.
Does KINGPO provide the complete laboratory building and civil construction?
No. KINGPO supplies the confirmed test equipment and integrated laboratory systems according to the approved technical proposal. Civil construction, building works, and room decoration are not included in the standard supply scope. Site electrical utilities, water supply, drainage, and equipment access conditions should be prepared and confirmed separately.
What site information is required before configuring the laboratory?
Customers should provide the available laboratory dimensions, entrance and equipment access conditions, site voltage, frequency, phase configuration, electrical capacity, water supply, and drainage conditions. Water heater sample specifications and required test items are also needed to review the suitability of the six-station test configuration.
How are test data recorded and managed?
The referenced laboratory uses a centralized data acquisition system for configured measurement channels. The software supports data storage, export, review, statistics, analysis, and printing, with a configurable sampling period from 5 to 60 seconds. Final software functions and recorded data fields should be confirmed in the project scope.
Can calibration and technical documentation be provided with the system?
Technical documentation can be prepared according to the confirmed equipment and project supply scope, including system configuration information, instrument details, and operating instructions. Calibration requirements for temperature, flow, electrical measurement, and data acquisition channels should be specified before quotation, particularly when the laboratory follows a defined quality management system.

Related Products

Related News

Water Heater Performance Tester checks IEC 60335 compliance by measuring safety, performance, and reliability for electric storage water heaters.
A Video Signal Generator creates test patterns to check display quality, color accuracy, and compliance, ensuring reliable video system performance.

In an era where product safety is paramount, flammability and flame retardant testing have become indispensable across multiple high-stakes industries: […]

IEC 62368-1 safety standard transition: key compliance steps, UL 62368-1 differences, and what manufacturers must do for global market access.
IEC 60950-1 withdrawal and IEC 62368-1 transition: Key EU compliance impacts, challenges, and steps for manufacturers to maintain product conformity.
An Environmental Test Chamber simulates temperature, humidity, and other conditions to test product durability, safety, and performance before market release.
Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.