ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector
The ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector is a stainless steel reference component used in enteral reservoir delivery system connector test configurations. It provides a defined cross port reservoir reference interface for laboratories and manufacturers working with ISO 18250-3 related connector verification.
- Applicable Standard: ISO 18250-3 Figure C.2
- Product Type: Cross port reservoir reference connector
- Test Application: Cross port reservoir connector / enteral reservoir delivery system connector verification
- Material: Stainless steel
- Typical Use: Used as a defined reference interface in ISO 18250-3 related connector test configurations
- Configuration Note: The required mating connector, sample structure, test item and fixture arrangement should be confirmed according to the selected ISO 18250-3 setup.
Product Overview
Role of the Figure C.2 Cross Port Reservoir Reference Connector in Testing
The ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector is used as a defined reference component when configuring tests for cross port reservoir connectors. Its main role is to provide the reservoir-side reference interface required for checking the mating relationship between the customer’s connector sample and the selected ISO 18250-3 test setup.
Unlike reference connectors that are mainly identified by male or female mating direction, Figure C.2 is more closely related to the cross port reservoir connector structure itself. The correct use of this reference connector depends on the sample design, required ISO 18250-3 figure number and the related test configuration.
KINGPO supplies the Figure C.2 cross port reservoir reference connector as a precision-machined stainless steel component for ISO 18250-3 related laboratory verification. The complete test arrangement should be confirmed before quotation, especially when the connector is required together with other reference connectors, leakage equipment or mechanical fixtures.
What This ISO 18250-3 Figure C.2 Connector Is Used For
The Figure C.2 cross port reservoir reference connector is mainly used where the test setup requires a defined cross port reservoir reference interface. It helps laboratories and manufacturers configure the mating condition before carrying out the required connector performance evaluation.
Typical applications include:
- Cross port reservoir connector verification
- Enteral reservoir delivery system connector test setup
- Reference interface confirmation for ISO 18250-3 related testing
- Connector mating configuration review
- Product validation for reservoir connector designs
- Laboratory quality control and pre-compliance checking
- Configuration support for multi-connector ISO 18250-3 test projects
The exact test method and fixture arrangement should be confirmed according to the applicable ISO 18250-3 figure number, sample connector structure and selected test item.
Cross Port Reservoir Connector Test Setup Notes
Figure C.2 is normally selected as part of a complete connector test configuration rather than as a standalone measuring instrument. Before use, the sample connector structure and mating direction should be reviewed to confirm whether Figure C.2 is the correct reference component for the intended setup.
For projects involving several ISO 18250-3 reference connectors, Figure C.2 may need to be considered together with other connector figures depending on the test item. The fixture design, alignment method and connection condition should be reviewed before testing, because these factors may affect how the sample interfaces with the reference connector.
Before quotation, it is helpful to confirm:
- Required ISO 18250-3 figure number
- Sample connector structure
- Intended test item
- Whether Figure C.2 is required as a single component or part of a connector set
- Whether matching reference connectors are also required
- Whether leakage or mechanical test equipment is needed
- Documentation requirements for dimensional inspection or material information

Configuration and Documentation Notes
The Figure C.2 cross port reservoir reference connector is made from stainless steel and intended for repeated laboratory handling when properly used, cleaned and stored. Since ISO 18250-3 connector testing may involve different connector combinations and fixture arrangements, the reference connector should be selected together with the complete test requirement.
Documentation requirements can be discussed before order. Depending on the project scope, dimensional inspection records, material information or other supporting documents may be prepared according to the agreed supply requirements.
Technical Features
| Item | Description |
|---|---|
| Standard Reference | ISO 18250-3 Figure C.2 |
| Connector Type | Cross port reservoir reference connector |
| Typical Application | Enteral reservoir delivery system connector verification |
| Material | Stainless steel |
| Test Setup Use | Reference interface configuration for ISO 18250-3 related connector tests |
| Supply Form | Single reference connector or part of an ISO 18250-3 connector configuration |
| Configuration Requirement | Sample structure, mating connector and intended test item should be confirmed before quotation |
| Documentation | Dimensional or material documentation can be discussed before order |
Technical Inquiry & Expert Support
ISO 18250-3 cross port reservoir connector testing may vary according to the sample structure, mating configuration and selected test item. KINGPO supports configuration review for Figure C.2 reference connector applications, including matching connector selection, fixture considerations and documentation requirements.
For projects involving enteral reservoir delivery system connector verification, our team can assist in confirming the suitable ISO 18250-3 reference connector configuration before quotation.
Typical Users
This reference connector is suitable for:
- Medical device manufacturers developing reservoir delivery system connectors
- Enteral reservoir connector and accessory manufacturers
- Third-party medical device testing laboratories
- Product validation and quality control departments
- R&D teams confirming cross port reservoir connector configuration
- Laboratories requiring ISO 18250-3 related reference connectors and test fixtures
Related KINGPO ISO 18250 Test Equipment
| Related Product | When to Use |
| ISO 18250-3 Reference Connectors Selection Guide | For complete ISO 18250-3 Figure C.1 to C.6 reference connector selection, test purpose comparison and configuration guidance |
| ISO 18250-3 Figure C.3 Reference Connector | For related cross-port reservoir connector test configurations involving leakage or unscrewing-related evaluation |
| ISO 18250-3 Figure C.4 Cross Reference Connector | For axial load separation and overriding resistance related configurations |
| ISO 18250-3 Figure C.5 Male Reference Connector | For test setups requiring a defined male reference connector |
| ISO 18250-3 Figure C.6 Female Reference Connector | For test setups requiring a defined female reference connector |
| ISO 18250-1 Subatmospheric Pressure Air Leakage Tester | For air leakage testing where the selected ISO 18250 configuration requires leakage equipment |
ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector
FAQ
Related Products
Related News
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]
You rely on the 6% taper angle when using iso 80369-7:2021 luer connectors. This special shape helps iso 80369-7 connectors […]