Limited Short Circuit Tester 1500A โ€“ KingPo IEC62368 Annex R Current Generator for Protective Conductor Testing
Limited Short Circuit Tester 1500A in Lab โ€“ Simulating 1500A Fault Current for Audio/Video Equipment Safety Validation
IEC62368 Annex R Limited Short-Circuit Tester ,Current Generator 1500 A
Limited Short Circuit Tester 1500A โ€“ KingPo IEC62368 Annex R Current Generator for Protective Conductor Testing
Limited Short Circuit Tester 1500A in Lab โ€“ Simulating 1500A Fault Current for Audio/Video Equipment Safety Validation
IEC62368 Annex R Limited Short-Circuit Tester ,Current Generator 1500 A

Limited Short Circuit Tester 1500A โ€“ IEC62368 Annex R Current Generator for Protective Conductor Testing

Limited Short Circuit Tester 1500A generates โ‰ฅ1500A fault currents (5-20ms discharge, DC120-250V) for IEC62368 Annex R protective conductor testing, with touch screen + PC control.

  • Standard Compliance: IEC62368-1 Annex R โ€“ direct reference for limited short-circuit testing
  • Output Current: โ‰ฅ1500A (customizable) โ€“ high fault simulation
  • Discharge Time: 5-20ms adjustable โ€“ precise pulse control
  • Control: 15-inch touch screen + PC interface โ€“ intelligent operation
  • MOQ: 1
  • Price: To be quoted
  • Standard Packaging: Safety carton or plywood box
  • Delivery Period: 15 days typical
  • Payment Method: T/T
  • Supply Capacity: 100 units/month

Limited Short Circuit Tester Description

Limited Short Circuit Tester 1500A โ€“ IEC62368 Protective Conductor Tester

The Limited Short Circuit Tester 1500A is a high-current test system manufactured by KingPo, designed to simulate fault currents for verifying protective grounding conductors and current-limiting devices in AV/IT/communication equipment. It delivers โ‰ฅ1500A output with 5-20ms discharge and DC120-250V voltage, fully compliant with IEC62368-1 Clause 5.6.4.1, 5.6.5.1 & Annex R.

KingPo Factory Advantages

ISO9001 & CE-certified manufacturer with global exports. KingPo provides precise, calibration-supported limited short-circuit testers for IEC62368 compliance, backed by responsive technical support and fast customization. This tester helps equipment producers validate conductor integrity under high fault currents, reduce safety risks, and cut compliance costs through reliable in-house testing.

Professional Construction & Technical Precision

Key features include:

  • Output Current: โ‰ฅ1500A โ€“ powerful fault simulation for protective devices
  • Discharge Time: 5-20ms adjustable โ€“ accurate pulse waveform control
  • Voltage Range: DC120-250V โ€“ flexible for different equipment ratings
  • Control: 15-inch touch screen + PC interface โ€“ intuitive setting and waveform analysis
  • Safety: Overcurrent/overvoltage protection, grounding/zero-return detection โ€“ safe operation

These ensure accurate, repeatable limited short-circuit testing.

Primary Use Cases & Business Value

The Limited Short Circuit Tester 1500A supports key stages:

  • Protective Conductor Validation โ€“ Test grounding wire compatibility with fault currents
  • Overcurrent Device Testing โ€“ Verify circuit breaker or fuse performance under 1500A
  • Certification Reporting โ€“ Generate compliant data for IEC62368-1 submissions
  • Production QC โ€“ Ensure conductor integrity in batch manufacturing

It helps deliver safe equipment, prevent overheating or fire hazards, and accelerate certification timelines.

Compliance & Regulatory Assurance

Fully compliant with IEC62368-1 Annex R limited short-circuit requirements. Aligned with CE, UL, CB Scheme, CCC for AV/IT equipment. Regular calibration recommended.

Procurement Benefits

Fast setup, detailed compliance documentation, and strong after-sales support. Accelerate IEC62368-1 certification, improve product safety and reliability, and minimize risks of non-compliance penalties or field failures. Contact us today for your Limited Short Circuit Tester 1500A quote โ€“ weโ€™ll respond within 24 hours with pricing, stock status, and technical details tailored to your needs.

Limited Short Circuit Tester 1500A Technical

Parameter Specification
Model Number IEC 62368-1 Annex R
Standards IEC62368-1 Annex R, GB 4943.1-2022
Output Current โ‰ฅ1500A (customizable)
Discharge Time 5-20ms adjustable
Output Voltage DC120-250V
Control Mode 15-inch touch screen + PC interface
Safety Features Overcurrent/overvoltage protection, grounding detection
Dimensions W1250 ร— D960 ร— H1650mm
Certifications ISO9001, CE
MOQ 1 unit
Price To be quoted
Standard Packaging Safety carton or plywood box
Delivery Period 15 days typical
Payment Method T/T
Supply Capacity 100 units/month
Warranty 1 year
Origin China (KingPo manufacturer)

 

Get Free Quote for Limited Short Circuit Tester 1500A

We provide high-precision Limited Short Circuit Tester 1500A direct from KingPo factory, ensuring reliable IEC62368 Annex R testing.

The Core Value We Deliver to You

  • High Current Capability โ€“ โ‰ฅ1500A for realistic fault simulation
  • Precision Control โ€“ 5-20ms discharge with PC waveform analysis
  • Factory Advantages โ€“ MOQ 1 unit, 15-day delivery, 1-year warranty, ISO9001 & CE
  • Complete Testing Support โ€“ Pair with our IEC62368 series for full checks
  • Faster Certification โ€“ Verify conductor integrity early, reduce safety risks

Take Action Now โ€“ Submit inquiry in 30 seconds for best price, stock status, and technical support within 24 hours!

Equipment Characteristics

1. Meet the test requirements of IEC62368-1:2018, EN62368-1:2019 and GB4943.1-2022 standards;

2. 15 inch super large true color touch LCD, high-speed thermal printer;

3. High precision sensor and high-performance 14 bit AD acquisition chip;

4. Man machine dialogue full keyboard operation mode, and the whole process of intelligent work;

5. Optional automatic current rise test, manual current rise test and impact quick break test, flexible and simple operation;

6. Real time display of output current and time results is intuitive;

7. Perfect over-current protection, arbitrary setting of target output current value, current upper limit and current withstand time;

8. With grounding detection function and zero return detection function, the test can be carried out after the grounding and zero return are determined, which is safe and reliable;

9. Approximation type current raising algorithm, when the set target output current is reached, the current tolerance timing will be automatic, and the motor will return to zero automatically after the timing is completed;

10. If the upper limit of the set output current is exceeded, the motor will automatically return to zero and give an audible and visual alarm;

11. Sophisticated anti-interference design of software and hardware, multiple anti-interference means, adapt to harsh electromagnetic environment;

12. It can be equipped with remote communication, door interlock alarm, opening voltage verification interface, etc.

Main Technical Parameters

1. Control mode: PLC control+touch screen man-machine interface intelligent operation;

2. Test station: 1 station;

3. Test range:<25A;

4. Limit current: โ‰ฅ 1500A (customizable);

5. Discharge time: 5~100ms can be set;

6. Test mode: AC and DC switchable test;

7. Discharge voltage: customized according to customer requirements;

8. Test time: touch screen can be set according to standard requirements;

9. Standard configuration: power supply DC power supply, over-current protection device, waveform curve oscilloscope provided by customers, configured with 2.5 square meters, 4 3m test lines;

10. Test function: discharge voltage and limit protection time can be set, with overvoltage and overcurrent protection function;

11. Safety protection: it has the function of abnormal shutdown alarm, and the connection is made of insulating materials;

12. Overall dimension: W1250 ร— D960 ร— H1650mm๏ผ›

13. Equipment power supply: AC220V 50Hz.

Minimum Protective Bonding Conductor Size of Copper Conductors

Minimum Protective Bonding Conductor Sizes (Copper Conductors)
Smaller of the rated current of the equipment or the protective current rating of the circuit under consideration (A) Up to and including Minimum Conductor Sizes Cross-sectional area (mmยฒ) AWG Equivalent [cross-sectional area in mmยฒ]
30 0.32 22 [0.324]
60 0.52 20 [0.519]
100 0.75 18 [0.8]
130 1.0 16 [1.3]
160 1.25 16 [1.3]
250 1.5 14 [2]
320 2.5 12 [3]
400 4.0 10 [5]
630 6.0 8 [8]
800 10 6 [13]
1000 16 4 [21]
1250 25 2 [33]
1600 35 1 [42]
1900 50 1/0 [53]
2300 70 2/0 [85]
2600 95 3/0 [107]

North American kcmil equivalents (for reference only)

Cross-sectional area (mmยฒ) kcmil Equivalent [mmยฒ]
120 250 [126]
150 300 [152]
185 400 [202]
240 500 [253]

 

Detail Display - IEC62368 Annex R Limited Short-Circuit Tester ,Current Generator 1500 A

Limited Short Circuit Tester 1500A FAQs

How does the Limited Short Circuit Tester 1500A simulate real fault currents safely?
It uses energy storage discharge (5-20ms) with DC120-250V and built-in overcurrent protection for controlled, safe testing.
Is this tester suitable for equipment rated under 25A?
Yes โ€“ itโ€™s specifically designed for โ‰ค25A equipment, verifying conductor compatibility with overcurrent devices per Annex R.
What if the test current exceeds the set limit โ€“ what happens?
The system automatically returns to zero and triggers an audible/visual alarm to prevent damage or unsafe conditions.
How accurate is the discharge current and time control?
High-precision sensors and 14-bit AD chip ensure reliable current-time curves, with discharge time adjustable from 5-20ms
What is the MOQ and delivery time for the Limited Short Circuit Tester 1500A?
MOQ 1 unit; delivery typically 15 days, allowing quick deployment for safety testing needs.
What warranty and support does KingPo offer?
1-year warranty plus lifetime technical support for long-term reliability.
How does this tester help prevent fire hazards in equipment?
It validates conductor withstand under 1500A faults, preventing overheating or melting in real-world short-circuit scenarios.
Can the tester support custom discharge times or voltages in R&D?
Yes โ€“ touch screen and PC interface allow flexible settings for prototype protective circuit validation.
How long does a typical short-circuit test cycle take?
A single cycle (charge + discharge) is quick (seconds to minutes), with automatic recharge for efficient repeated testing.
How to get a quote or sample for the Limited Short Circuit Tester 1500A?
Submit the inquiry form or email [email protected] for pricing and fast support.

Related Products

Related News

In the complex world of electrical engineering and manufacturing, ensuring the safety of electrical components is paramount. One of the […]

Impulse test generator features for IEC 62368-1: dual waveforms, adjustable voltage, and safety controls make compliance and electrical testing simple.

For plastic insulation frames, given the high heat generated by the copper wires and iron core, if the flame retardant […]

Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]

In ANSI/CAN/UL 3300 (latest edition as of 2024/2025 revisions), simulated dummies (also called targets, child targets, or anthropomorphic test devices) […]

IP (Ingress Protection) ratings are enclosure protection standards developed by the International Electrotechnical Commission (IEC), primarily assessing the ability of […]

Abstract Routine tests are mandatory production-line verifications performed on each unit of electrical equipment intended for measurement, control, and laboratory […]

IP ratings explained: Understand each code, what the digits mean, and how to choose the right protection level for electronics in any environment.
Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.