IEC 60335-1 cord reel endurance tester front view in a laboratory
Automatic cord reel endurance tester shown from an angled side view
High-angle view of an IEC 60335-1 cord reel tester and sample fixture area
IEC 60335-1 cord reel endurance tester front view in a laboratory
Automatic cord reel endurance tester shown from an angled side view
High-angle view of an IEC 60335-1 cord reel tester and sample fixture area

Automatic Cord Reel Endurance Tester for IEC 60335-1 Clause 22.16

The IEC 60335-1 cord reel endurance tester is designed for repeated cord extension and automatic retraction testing in accordance with Clause 22.16. Its pneumatic drive, adjustable settings and preset cycle control support controlled endurance testing of retractable power-cord systems.

  • Applicable Standard: IEC 60335-1 Clause 22.16
  • Test Application: Endurance testing of automatic cord reels used in household and similar electrical appliances
  • Main Test Purpose: Evaluates the effects of repeated cord extension and automatic retraction on the flexible cord, reel mechanism and electrical contacts
  • Typical Test Samples: Vacuum cleaners, floor-care appliances and other products equipped with retractable power-cord systems
  • Test Method: Pneumatic cord withdrawal followed by automatic retraction through the sample’s own reel mechanism
  • Adjustable Test Settings: 5–30 cycles/min test speed, 30°–70° withdrawal angle and up to 1000 mm withdrawal stroke
  • Cycle Control: Preset test count from 0 to 9999 cycles with automatic stop
  • Sample Configuration: Fixture arrangement can be adapted according to the appliance size, cord outlet position and normal-use orientation

Product Overview

Product Overview

Automatic cord reels are exposed to repeated mechanical stress throughout the service life of an appliance. Each operating cycle subjects the flexible cord, outlet structure and reel mechanism to pulling, bending, friction and recoil. Over time, these repeated actions may contribute to cord damage, conductor deterioration or wear of the reel contacts.

The tester provides a controlled laboratory method for reproducing these operating conditions. The appliance or cord reel assembly is mounted in a representative working position, while the withdrawal distance, pulling direction, operating speed and test cycles are set according to the applicable test requirements and sample construction.

Unlike a conventional supply-cord flexing tester, this equipment evaluates the complete extension-and-retraction operation of an automatic cord reel system.

Technical Specifications

The main test parameters and installation requirements are summarized below for quick technical and purchasing review. Final sample compatibility should be confirmed according to the appliance dimensions, cord outlet position and reel construction.

Test Parameters
Applicable Standard IEC 60335-1 Clause 22.16
Test Object Automatic cord reels for household and similar electrical appliances
Drive System Pneumatic
Test Speed 5–30 cycles/min, adjustable
Preset Cycle Range 0–9999 cycles
Cycle Completion Automatic stop when the preset count is reached
Withdrawal Angle 30°–70°, adjustable
Withdrawal Stroke Up to 1000 mm, adjustable
Retraction Method Automatic retraction by the sample’s own cord reel mechanism

Sample Mounting and Installation
Sample Mounting Work platform with quick-clamping fixture
Sample Orientation Adjustable according to cord outlet position and test direction
Fixture Configuration Confirmed according to sample size and reel structure
Power Supply AC 220 V, 50 Hz, subject to final configuration
Compressed-Air Supply 5–7 kgf/cm²
Installation Requirement External compressed-air source and suitable electrical supply
i

Configuration Note
Appliance size, weight, cord length, outlet position and normal-use orientation should be reviewed before quotation to confirm fixture suitability and machine setup.

Applicable Standard and Test Purpose

The equipment is designed for the automatic cord reel endurance test specified in IEC 60335-1 Clause 22.16.

IEC 60335-1 covers safety requirements for household and similar electrical appliances. The applicable standard edition, national adoption and relevant product-specific Part 2 standard should be confirmed for each testing project.

The test is intended to evaluate whether repeated operation of an automatic cord reel causes:

Undue abrasion or damage to the flexible cord sheath
Breakage of conductor strands
Undue wear of electrical contacts

The tester performs the repeated mechanical operation required for the endurance procedure. Final inspection and assessment should be carried out according to the applicable standard edition and laboratory test procedure.

Laboratory technician operating an IEC 60335-1 cord reel endurance tester

What This Equipment Tests

01

Flexible Cord Sheath Condition

During normal use, the flexible cord repeatedly moves through the appliance outlet or guiding structure. The endurance test reproduces this movement so the cord can be examined for excessive abrasion or mechanical damage after testing.

02

Conductor Mechanical Endurance

Repeated extension, bending and recoil apply mechanical stress to the conductor strands inside the flexible cord. After the endurance cycles, conductor condition can be examined according to the applicable test procedure.

03

Reel Mechanism and Contact Wear

Automatic reel systems may include return mechanisms, rotating components and electrical contacts. Testing the complete extension-and-retraction cycle helps evaluate deterioration associated with repeated reel operation.

Testing Principle and Procedure

The appliance or automatic cord reel assembly is secured on the test platform in a position representative of normal use. The pulling mechanism is aligned with the cord outlet, and the withdrawal distance, angle, speed and number of cycles are set according to the applicable standard and sample construction.

1
The pneumatic mechanism withdraws the flexible cord through the selected distance.
2
The sample’s automatic reel mechanism retracts the cord.
3
One completed withdrawal-and-retraction cycle is recorded.
4
The withdrawal and retraction sequence is repeated according to the preset cycle requirement.
5
The tester stops automatically when the preset cycle count is reached.
The withdrawal direction and sample position should be selected according to the cord outlet arrangement and relevant test condition. The reel must be able to complete the retraction action correctly throughout the endurance sequence.

After testing, the flexible cord, conductor condition, reel contacts and mechanical operation are inspected according to the applicable test requirements.

Main Equipment Features

DRIVE SYSTEM

Pneumatic Cord Withdrawal

The pneumatic drive repeatedly withdraws the flexible cord while the sample’s own reel mechanism performs the retraction action. This reproduces the interaction between the cord, outlet structure and automatic reel.

SPEED CONTROL

Adjustable Test Speed

The test speed can be adjusted from 5 to 30 cycles per minute. The operating rate can be selected according to the test procedure and the operating capability of the sample reel.

TEST DIRECTION

Adjustable Withdrawal Direction

The withdrawal angle is adjustable from 30° to 70°, allowing the pulling direction to be set according to appliance orientation and cord outlet geometry.

TEST STROKE

Adjustable Withdrawal Stroke

The withdrawal stroke can be adjusted up to 1000 mm. The selected stroke should reflect the applicable test procedure, available cord length and operating limits of the reel.

CYCLE CONTROL

Preset Cycle Control

A test count from 0 to 9999 cycles can be preset before operation. The tester stops automatically when the programmed number of cycles has been completed.

SAMPLE FIXTURE

Adaptable Sample Mounting

The work platform and quick-clamping arrangement support different appliance and cord reel configurations. Fixture suitability should be reviewed according to actual sample dimensions and cord outlet location.

Typical Applications

The Automatic Cord Reel Endurance Tester is intended for products incorporating an automatic retractable supply cord.


MANUFACTURERS

Household Appliance Compliance Testing

Appliance manufacturers and internal compliance laboratories can use the equipment for design verification and standards-based cord reel endurance testing.

TYPICAL SAMPLES

Vacuum cleaners

Floor-care appliances

Retractable cord appliances


TEST LABS

Third-Party Testing Laboratories

Independent testing and inspection organizations can use the equipment for controlled automatic cord reel endurance procedures associated with IEC 60335-1 testing.

LABORATORY VALUE

Controlled endurance cycles

Adjustable motion settings

Sample fixture review


R&D

Product Development and Reliability Evaluation

R&D and quality teams can use repeated cord reel operation to identify mechanical deterioration and compare the performance of different cord or reel designs.

EVALUATION FOCUS

Cord sheath and conductor damage

Incomplete or unstable retraction

Reel and contact deterioration

i
For comparative or development testing outside a standard compliance procedure, the selected speed, stroke, angle and cycle count should be documented as project-specific test conditions.

Sample and Configuration Review

Automatic cord reel systems vary in appliance size, cord length, outlet geometry, reel location and normal-use orientation. Sample review before quotation helps determine whether the standard fixture arrangement is suitable or whether fixture adaptation is required.

The following information should be confirmed:

Applicable standard edition and clause
Applicable product-specific Part 2 standard
Appliance type
Complete appliance or cord reel assembly
Sample dimensions and weight
Total and withdrawable cord length
Cord outlet position and direction
Normal-use orientation of the appliance
Required withdrawal distance
Required test angle and speed
Required test cycle count
Local power supply
Available compressed-air pressure
Fixture requirements

Sample photographs or drawings showing the appliance, cord outlet and reel arrangement are recommended for configuration review.


Function Boundary

The basic published configuration is intended for mechanical endurance operation. Functions such as conductor continuity monitoring, electrical loading or automatic failure detection should be confirmed separately when required.

Difference from Related Cord Test Equipment

Cord-related tests in the IEC 60335 series evaluate different failure modes. Equipment should be selected according to the applicable clause and the actual movement or mechanical stress applied to the cord.

THIS PRODUCT

Automatic Cord Reel Endurance Tester

Used for repeated extension and automatic retraction of a cord reel system. The test involves the flexible cord, cord outlet, return mechanism and reel contacts during repeated reel operation.

Supply Cord or Wiring Flexing Tester

Used to repeatedly flex a cord or wiring at a defined position. It evaluates flexing endurance and does not reproduce the complete extension-and-retraction action of an automatic reel.

Cord Anchorage Pull and Torque Tester

Used to apply pulling and twisting forces to a supply cord and its anchorage. It evaluates cord retention rather than repeated automatic reel operation.

Swivel Connection Flexing Tester

Used for repeated movement of rotating or pivoting cord connections. Its test motion and evaluation purpose differ from automatic cord reel endurance testing.

Compliance & Regulatory Assurance

The Automatic Cord Reel Endurance Tester is designed for testing in accordance with IEC 60335-1 Clause 22.16,supporting the evaluation of retractable power-cord systems used in household and similar electrical appliances. The applicable IEC edition, national adoption and product-specific Part 2 standard should be confirmed for each compliance testing project.

Test Integrity & Configuration Verification

  • Test speed, withdrawal stroke, pulling angle and cycle count should be set according to the applicable standard procedure and sample construction.
  • Sample orientation and fixture arrangement should be reviewed to reproduce the intended cord withdrawal and automatic retraction conditions.
  • Proper equipment inspection and operating-condition verification help support repeatable endurance test results and reliable laboratory assessment.

Download IEC 60335-1 Cord Reel Endurance Tester Catalog

Download the KINGPO product catalog for the IEC 60335-1 Clause 22.16 automatic cord reel endurance tester, including product information, technical specifications, test application notes and configuration guidance for retractable power-cord endurance testing.

Download PDF

Technical Inquiry & Expert Support

KINGPO supplies automatic cord reel endurance test equipment for household and similar electrical appliance testing in accordance with IEC 60335-1 Clause 22.16.
Our engineering team can assist with sample review, fixture arrangement, test parameter confirmation and machine configuration. For technical specifications or quotation support, please provide the appliance type, cord reel arrangement and applicable test requirements.

The Core Value We Deliver



Dedicated automatic cord reel endurance testing for IEC 60335-1 Clause 22.16 household appliance applications.



Pneumatic cord withdrawal with adjustable test speed, withdrawal angle, stroke and preset cycle control.



Suitable for vacuum cleaners, floor-care equipment and other appliances incorporating retractable power-cord systems.



Sample and fixture configuration review based on appliance dimensions, cord outlet position and normal-use orientation.



Engineering support for equipment setup and application of the IEC 60335-1 automatic cord reel endurance test procedure.

Detail Display

FAQ

What is the IEC 60335-1 cord reel endurance tester used for?
The IEC 60335-1 cord reel endurance tester is used to reproduce repeated extension and automatic retraction of retractable power cords. It helps laboratories evaluate the effects of repeated reel operation on the flexible cord, cord outlet, reel mechanism and electrical contacts in household and similar electrical appliances.
Which standard applies to the automatic cord reel endurance test?
The equipment is designed for the automatic cord reel endurance test associated with IEC 60335-1 Clause 22.16. Before testing or quotation, the applicable IEC edition, national adoption and relevant product-specific Part 2 standard should be confirmed, because the complete compliance requirements may depend on the appliance category and certification project.
What types of appliances can be tested with this equipment?
Typical applications include vacuum cleaners, floor-care equipment and other household or similar appliances incorporating an automatic retractable supply cord. Suitability is not determined by the appliance name alone. The sample dimensions, weight, cord length, cord outlet position and normal-use orientation should be reviewed before the test fixture and machine arrangement are confirmed.
How does the automatic cord reel endurance tester perform the test?
The pneumatic mechanism withdraws the flexible cord through the selected distance, while the sample's own automatic reel mechanism retracts the cord. Each completed withdrawal-and-retraction sequence is counted as an operating cycle. The sequence continues until the preset cycle count is reached, after which the tester stops automatically.
Can the withdrawal speed, angle and stroke be adjusted?
Yes. The published machine configuration provides adjustable test speed, withdrawal direction and withdrawal stroke to accommodate different reel constructions and test setups. The available ranges are 5–30 cycles/min, 30°–70° withdrawal angle and up to 1000 mm stroke. Final settings should follow the applicable test procedure and sample operating conditions.
Can a complete appliance be mounted on the cord reel tester?
A complete appliance may be tested when its size, weight, cord outlet arrangement and normal-use orientation are compatible with the work platform and fixture configuration. For larger or unusual products, KINGPO recommends reviewing sample drawings or photographs before quotation to determine whether the standard clamping arrangement is suitable or fixture adaptation is required.
Is an external compressed-air supply required for operation?
Yes. The standard published configuration uses a pneumatic drive for repeated cord withdrawal and therefore requires an external compressed-air source. The available laboratory air supply should be confirmed before installation. Stable pneumatic conditions are important for consistent machine operation, particularly when the tester is used for repeated endurance cycles over an extended test period.
Does the tester automatically detect broken conductors or electrical contact failure?
Automatic conductor continuity monitoring, electrical loading and automatic failure detection are not confirmed as standard functions of the basic published configuration. The machine is primarily intended to perform the mechanical withdrawal-and-retraction endurance action. If electrical monitoring or failure detection is required, this should be specified during the technical configuration review.
How is this tester different from a supply cord flexing tester?
A cord reel endurance tester evaluates repeated extension and automatic retraction of the complete reel system, including interaction between the cord, outlet and return mechanism. A supply cord flexing tester mainly applies repeated bending at a defined cord entry or connection point. The two machines address different test motions and should not be treated as interchangeable equipment.
What information should be provided before requesting a quotation?
Please provide the applicable standard and edition, appliance type, sample dimensions and weight, total and withdrawable cord length, cord outlet position and normal-use orientation. Sample photographs or drawings are also recommended. This information helps KINGPO review fixture suitability, withdrawal direction, stroke requirements and the appropriate automatic cord reel endurance tester configuration before quotation.

Related Products

Related News

KingPo Eurofins IEC 60335 Test Equipment Delivered to Finland Espoo, Finland — Jun 2023 —A complete set of high-precision IEC 60335 […]

KingPo Delivers IEC 60335 Test Equipment to Intertek Hong Kong and Korea   Hong Kong & Seoul, March 2023 — KingPo […]

KingPo UL Vietnam IEC 60335 Test Equipment Delivered for IEC 62368-1 Compliance   Hai Duong Province, Vietnam — KingPo is […]

Water Heater Performance Tester checks IEC 60335 compliance by measuring safety, performance, and reliability for electric storage water heaters.

Essential equipment for residual voltage testing under IEC 60601-1, IEC 60335-1, IEC 61010-1, IEC 62368-1 and similar safety standards. 1. […]

As service robots (Service Robots) are increasingly deployed in commercial, public, and healthcare environments, human-robot interaction safety, mobility-related hazards, and […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.