




ISO 18250-3 Figure C.6 Female Reference Connector
The ISO 18250-3 Figure C.6 Female Reference Connector is a stainless steel reference connector used in reservoir delivery system connector test setups. It provides the defined female mating interface required when evaluating the connection performance of matching male enteral reservoir connectors under selected ISO 18250-3 test requirements.
- Applicable Standard: ISO 18250-3 Figure C.6
- Product Type: Female reference connector
- Test Sample: Matching male enteral reservoir connector
- Application: Reservoir delivery system connector testing for enteral applications
- Material: Stainless steel
- Typical Test Use: Leakage, stress cracking, axial separation, unscrewing separation and overriding related test setups
- Configuration Note: Selection should be confirmed according to the required figure number, mating connector direction and intended test item.
Product Overview
Role of the Figure C.6 Female Reference Connector in Testing
The ISO 18250-3 Figure C.6 Female Reference Connector is used as the defined female mating connector in test configurations involving male enteral reservoir connectors. During testing, the customer’s male sample connector is assembled with the Figure C.6 reference connector so that the connection interface can be evaluated under the required leakage or mechanical performance conditions.
This reference connector is not only a dimensional checking part. It forms part of a functional test setup where the mating condition, connection stability and resistance to separation are important to the final evaluation. For this reason, the correct reference connector direction must be confirmed before quotation or testing.
KINGPO supplies the Figure C.6 female reference connector as a precision-machined stainless steel component for ISO 18250-3 related connector verification. The final test setup may require additional leakage, force or torque fixtures depending on the selected test item.
What This ISO 18250-3 Figure C.6 Connector Is Used For
The Figure C.6 female reference connector is mainly used when the tested sample is a matching male enteral reservoir connector. It provides the required female reference interface for checking whether the sample connector can maintain the intended connection performance during laboratory testing.
Typical use cases include:
- Male enteral reservoir connector verification
- Reservoir delivery system connector compatibility checking
- Leakage test setup with a defined female mating connector
- Mechanical separation resistance evaluation
- Unscrewing resistance related test configuration
- Overriding resistance related test configuration
- Product validation and quality control for enteral connector designs
The applicable test item, pressure condition, force condition or torque condition should be confirmed according to the selected ISO 18250-3 test requirement.

Testing Setup Notes
The Figure C.6 female reference connector is normally used together with the customer’s male sample connector and the required auxiliary test equipment. The complete setup may vary depending on whether the project involves leakage testing, axial separation testing, unscrewing testing or overriding evaluation.
For leakage-related tests, the pressure source, test medium and sealing method should be confirmed before configuring the setup. For mechanical tests, the required force or torque application method should be reviewed together with the sample structure.
This product should therefore be selected by figure number and mating direction, not only by product name.
Configuration and Documentation Notes
The connector is manufactured from stainless steel and intended for repeated laboratory handling when properly used, cleaned and stored. Because ISO 18250-3 connector tests may involve different test methods, customers should confirm whether they need only the Figure C.6 female reference connector or a complete test configuration.
Documentation requirements can be discussed before order. Depending on the project, dimensional inspection records, material information or other supporting documents may be prepared according to the agreed supply scope.
Technical Features
| Item | Description |
|---|---|
| Standard Reference | ISO 18250-3 Figure C.6 |
| Connector Type | Female reference connector |
| Typical Test Sample | Matching male enteral reservoir connector |
| Main Application | Reservoir delivery system connector testing for enteral applications |
| Material | Stainless steel |
| Test Setup Use | Leakage, separation, unscrewing and overriding related test configurations |
| Supply Form | Single reference connector or part of an ISO 18250-3 connector configuration |
| Documentation | Dimensional or material documentation can be discussed before order |
Technical Inquiry & Expert Support
ISO 18250-3 connector test setups may vary according to the required figure number, mating connector structure and selected performance test. KINGPO supports configuration review for Figure C.6 female reference connector applications, including matching connector selection, leakage test setup considerations and documentation requirements.
For projects involving reservoir delivery system connector verification, our team can assist in confirming the suitable reference connector configuration before quotation.
Typical Users
This reference connector is suitable for:
- Medical device manufacturers developing reservoir delivery system connectors
- Enteral feeding connector and accessory manufacturers
- Third-party medical device testing laboratories
- Product validation and quality control departments
- R&D teams confirming connector mating performance
- Laboratories requiring ISO 18250-3 related reference connectors
Related KINGPO ISO 18250 Test Equipment
| Related Product | When to Use |
|---|---|
| ISO 18250-3 Reference Connectors Selection Guide | For complete ISO 18250-3 Figure C.1 to C.6 reference connector selection, test purpose comparison and configuration guidance |
| ISO 18250-3 Figure C.5 Male Reference Connector | For test setups requiring the corresponding male reference connector |
| ISO 18250-3 Figure C.2 Cross Port Reservoir Reference Connector | For cross-port reservoir connector related configurations |
| ISO 18250-3 Figure C.3 Reference Connector | For ISO 18250-3 test setups requiring Figure C.3 |
| ISO 18250-3 Figure C.4 Cross Reference Connector | For related cross reference connector test configurations |
| ISO 18250-1 Subatmospheric Pressure Air Leakage Tester | For air leakage testing where the selected test method requires matching leakage equipment |
ISO 18250-3 Figure C.6 Female Reference Connector
FAQ
Related Products
Related News
ISO 80369-7 Figure C.2 Male Luer Lock Reference Connector Our 80369-7 compliant Figure C.2 male luer reference connectors are precision-engineered […]