Charge and Discharge Battery Testing Machine โ RCDS-100V100A for Lithium-Ion Battery Cycle Life Testing
Charge and Discharge Battery Testing Machine (RCDS-100V100A) supports automated cycle life, capacity, and overload testing for lithium-ion, lead-acid, NiCd, and NiMH batteries with 150mA minimum current and energy feedback.
- Standard Compliance: CNAS calibration certified โ third-party verified accuracy
- Voltage Range: 0.2Vโ100V โ wide coverage for various battery modules
- Current Range: -200A to +200A (minimum output 150mA) โ high-precision control
- Power Output: Up to 10kW per channel โ supports continuous high-load testing
- MOQ: 1
- Price: To be quoted
- Standard Packaging: Safety plastic tool box or plywood package
- Delivery Period: 15 days typical
- Payment Method: T/T
- Supply Capacity: 20 units/month
Product Description
Charge and Discharge Battery Testing Machine โ RCDS-100V100A Cycle Life Tester
The Charge and Discharge Battery Testing Machine (RCDS-100V100A) is a high-precision automated system manufactured by KingPo, designed for cycle life, capacity, charging/discharging characteristics, and overload testing of lithium-ion, lead-acid, NiCd, and NiMH batteries. It features energy feedback (up to 90% efficiency), 150mA minimum current, and full automation for production line or laboratory use.
Device Specific Advantages (Optimized)
- Energy Feedback System Standard sine wave feedback (max efficiency 90%) enables bidirectional energy recovery, significantly reducing electricity consumption and air conditioning costs for cooling generated heat.
- Seamless CCCV Charging No-gap transition between CC and CV modes prevents voltage/current spikes, effectively avoiding PCB protection triggers, secondary protection actions, and risks from peak current (e.g., tab overheating, micro-short circuits, island effect, or overshoot).
- High-Precision Sampling High-accuracy, high-dynamic-range ADC/DAC units deliver excellent long-term stability for voltage and current measurements.
- Multi-Level User Management Permission, role, and user management system allows administrators to assign granular access rights to different functional modules and create multiple operator accounts.
- DL Dynamic Load Protection Protects batteries during charge/discharge, prevents fire hazards, and mitigates current shocks from connector loosening, safeguarding sensitive components (MOSFET, FUSE, etc.).
- Voltage Clamp Protection During charging, clamps voltage to safe levels if protection triggers or equipment abnormality occurs, preventing damage to the battery or protection board.
- Segmented Recording & Intelligent Data Management Test steps support sectional recording conditions for smart, efficient data management.
- BMS CAN Communication Real-time reading of BMS data (total voltage, current, cell voltage, temperature, etc.) for synchronous comparison with test data. Supports conditional step control (e.g., stop or transition) based on BMS values.
- Custom Signal & Protection Logic Users can define custom signals and names. Supports multiple protection parameters with operator functions (max, min, difference, mean, +, -, ร) to create complex decision conditions.

File query: can be based on the test date, test channels, keywords and other information search related, and support data batch export

Software Testing Interface

Setup interface

Data interface

Curve alignment interface

Working condition simulation setup interface

Working condition simulation data interface

Professional Construction & Technical Precision
Key features include:
- Voltage Range: 0.2Vโ100V โ continuously adjustable for broad battery compatibility
- Current Range: -200A to +200A โ minimum output 150mA with ยฑ0.05% FS accuracy
- Power Output: Up to 10kW per channel โ continuous operation with energy feedback
- Test Modes: CCCV charging, constant current/power/resistance discharge โ seamless transitions
- Data Acquisition: High-speed sampling (10ms resolution) with BMS CAN communication โ real-time monitoring
These ensure accurate, repeatable battery performance testing.
Primary Use Cases & Business Value
The Charge and Discharge Battery Testing Machine supports key stages:
- Production Line Testing โ Automate batch cycle life and capacity validation
- R&D Validation โ Test charging characteristics, efficiency, and temperature rise in new designs
- Certification Reporting โ Generate traceable data for quality and safety submissions
- Failure Analysis โ Identify capacity fade or overload issues in returned batteries
It helps deliver reliable batteries, reduce defect rates, and accelerate market readiness.
Procurement Benefits
Fast setup, detailed compliance documentation, and strong after-sales support. Accelerate battery quality validation, improve production efficiency and product reliability, and minimize risks of non-compliance or performance failures. Contact us today for your Charge and Discharge Battery Testing Machine quote โ weโll respond within 24 hours with pricing, stock status, and technical details tailored to your needs.
Charge and Discharge Battery Testing Machine Applications
| No. | Parameter / Feature | Specification / Details |
|---|---|---|
| 1 | Number of Main Channels | 4 CH per rack |
| 2 | Output Power | Maximum 10kW per channel (no time limit) |
| 3 | Output Power Stability | ยฑ(0.1% FS + 0.1% RD) |
| 4 | Input Power Quality | Power factor >99% (loaded to capacity) Total harmonic distortion โค5% (loaded to capacity) |
| 5 | Energy Consumption | Standard sine wave feedback energy, maximum efficiency 90% |
| 6 | Main Channel Working Modes | Charging: CC, CV, CCCV (no impulse transition) Discharge: CC, CP, CR Support: Working condition test, Pulse test |
| 7 | Main Channel Voltage | Measurement Range: 0.2Vโ100V (continuously adjustable) Minimum Discharge Voltage: 7V Accuracy: ยฑ(0.05% FS + 0.05% RD) Resolution: 1mV |
| 8 | Main Channel Current | Measurement Range: -200A to +200A Minimum Output Current: 150mA Accuracy: ยฑ(0.05% FS + 0.05% RD) Resolution: 1mA Response Time: <10ms |
| 9 | Optional Auxiliary Voltage Channels | Number of Channels: 32 Measurement Range: DC 0โ5V Accuracy: ยฑ(0.05% FS + 0.05% RD) Resolution: 1mV |
| 10 | Optional Auxiliary Temperature Channels | Number of Channels: 8 Measurement Range: -50โ to +300โ Accuracy: ยฑ1โ Resolution: 0.1โ |
| 11 | Data Acquisition Resolution | 10ms |
| 12 | Communication Modes | LAN support BMS: CAN 2.0A / CAN 2.0B, RS485 (supports DBC import) |
| 13 | Control Program Features | Power-down data protection, online step modification, safety protection conditions (voltage/current/temperature limits) |
| 14 | Cycle Index & Programmable Steps | Max 10,000 cycles Max 10,000 steps Max 10-level loop nesting |
| 15 | Step Time Range | Unlimited (supports h/min/s format) |
| 16 | Data Recording Interval | Time โฅ10ms, Voltage โฅ0.1% FS, Current โฅ0.1% FS (step-by-step configurable) |
| 17 | Protection Functions | Over-voltage, over-current, short-circuit, over-temperature, reverse connection, power-off protection |
| 18 | Alarm & Safety Features | Emergency stop switch, automatic shutdown on power failure, audible/visual alarms |
| 19 | Cooling Method | Forced air cooling |
| 20 | Sampling Terminals | Four-electrode sampling mode |
| 21 | Noise Level | <70 dBA (Type I sound level meter, accuracy ยฑ0.5 dB) |
| 22 | Protection Level | IP20 |
| 23 | Maintainability & Upgrades | Modular structure, spare parts replaceable, free maintenance during warranty Software upgrades until hardware incompatibility |
Get Free Quote of Charge And Discharge Battery Testing Machine Minimum Output Current 150mA
We provide high-precision Charge and Discharge Battery Testing Machine direct from KingPo factory, ensuring reliable battery cycle life and performance testing.
The Core Value We Deliver to You
- High Efficiency โ Energy feedback up to 90% for cost savings
- Precision Control โ 150mA min current, ยฑ0.05% FS accuracy
- Factory Advantages โ MOQ 1 unit, 15-day delivery, 1-year warranty, ISO9001 & CE
- Complete Testing Support โ Pair with our battery series for full checks
- Faster Certification โ Identify performance risks early, reduce failures
Take Action Now โ Submit inquiry in 30 seconds for best price, stock status, and technical support within 24 hours!
Charge and Discharge Battery Testing Machine Technical
- Lithium-Ion Batteries โ Cycle life and capacity validation
- Lead-Acid & NiMH Batteries โ Charging/discharging characteristics testing
- Production Lines โ High-throughput batch QC for battery manufacturing
- Certification Labs & QA โ Third-party CNAS-compliant performance testing
- Global Certifications โ Supports CE, UL, CB Scheme, CCC by verifying battery reliability
Software Testing Interface - Charge And Discharge Battery Testing Machine Minimum Output Current 150mA
Charge and Discharge Battery Testing Machine FAQs
Related Products
Related News
Introduction: The Hidden Threat in Your Devices Every year, thousands of residential and industrial fires are traced back to a […]
Dongguan, China โ 10 25, 2024 โ In a significant advancement for food safety technology, Chao Zhang (also known as […]