KP-1050S Defibrillation Test Pulse Generator for Medical Device Safety
The KP-1050S defibrillation test simulator ensures medical device safety compliance, offering reliability and precise electrical performance verification.
- Standard Compliance: IEC 60601-1 – Direct reference for defibrillation pulse testing
- Pulse Simulation: Accurate defibrillation waveform generation
- High Voltage Capability: Safe, repeatable high-energy pulse delivery
- Durable Construction: Robust design for medical lab reliability
MOQ: 1
Price: To be quoted
Payment Method: T/T
Product Description
The KP-1050S defibrillation test pulse generator is used to evaluate whether active implantable medical devices will be permanently affected when subjected to damped sine defibrillation waveforms and truncated exponential defibrillation waveforms , whether they can be reprogrammed to restore settings , and to evaluate the safety and programmability of the product. The KP-1050S defibrillation test pulse generator complies with ISO14708-1 and GB 16174.1-2024 20.2 standards. The following test procedures are included:
-
Test 1
1. Test Purpose :
To evaluate whether active implantable medical devices are permanently affected when subjected to damped sinusoidal defibrillation waveforms and whether they can be reprogrammed to restore settings.
2. Test equipment :
Defibrillation test voltage generator, used to provide a damped sinusoidal defibrillation waveform with specific characteristics.
3. Test parameters :
The parameters of the damped sinusoidal defibrillation waveform must meet the following requirements: 1.5ms < Tp < 2.5ms; 3ms < Tw50 < 5.5ms; where Tp is the time interval from the start of the waveform to the maximum value, and Tw50 is the time interval above 50% of the maximum value.
The maximum value of the test voltage Vtest is adjusted to 140+70V.
-
Test 2
1. Purpose of the study :
To further evaluate the safety and reprogrammability of active implantable medical devices when subjected to truncated exponential defibrillation waveforms.
2. Test equipment :
A defibrillation pulse generator is used to provide a truncated exponential defibrillation waveform of a specific duration.
3. Test arrangement :
Test arrangement using C1=(150±50)μF, R1=65Ω and 2 sets of coupled switches S1 and S2.
A single-phase or bi-phase truncated exponential defibrillation waveform with a duration of Td = (10 ± 0.5) ms is generated between output terminals A and B.
4. Test parameters :
The test voltage-time parameters of the truncated exponential defibrillation waveform must meet the numerical range in Table 1.
The maximum value of the test voltage Vtest is adjusted to 140+70V.
This model of pulse tester uses a programmable controller as its core and is equipped with a color touch screen for intuitively displaying and setting all working parameters and instrument status. Its user-friendly design makes the operation interface concise and clear, and it can memorize various parameters even in the case of power failure, greatly improving the convenience of use. In terms of safety performance, this model of pulse tester has a built-in overvoltage protection device, which effectively guarantees the stable operation of the instrument during the test and ensures the safety and reliability of the test work. In addition, it also has the characteristics of easy operation, excellent performance, high reliability and good cost performance. Therefore, it is deeply favored by electrical safety testing laboratories and electronic and electrical appliance manufacturers, and has become their preferred tool for electrical safety testing.
Detail Information
| Place of Origin | China | Brand Name | Kingpo |
| Certification | iso9001 ce | Model Number | KP-1050S |
| Voltage Measurement Accuracy: | AC 110/220V | Input Power: | AC 110/220V ±10%, 50/60Hz, 425W |
| Weight: | 22.5 Kg | ||
| Highlight: | AC 110/220V Test Pulse Generator, 425W Test Pulse Generator, Implantable Medical Device Test Pulse Generator | ||
Get Free Quote of KP-1050S Defibrillation Test Pulse Generator for Medical Device Safety
We provide high-precision Defibrillation Test Pulse Generator direct from KingPo factory, ensuring reliable IEC 60601-1 medical safety testing.
The Core Value We Deliver to You
- Exact IEC 60601-1 compliance – Accurate defibrillation pulse simulation
- High Reliability – Robust design for repeatable results
- Factory Advantages – MOQ 1 unit, 15-day delivery, 1-year warranty, ISO9001 & CE
- Complete Testing Support – Pair with our IEC series for full checks
- Faster Certification – Identify safety risks early, reduce failures
Take Action Now – Submit inquiry in 30 seconds for best price, stock status, and technical support within 24 hours!
Technical Indicators
| Technical Projects | Parameter |
| Comply with standards | ISO 14708-1:2014 & GB 16174.1-2024 20.2 |
| Test 1 voltage | 140+70V |
| Test 1 Circuit | RLC Circuit |
| Damped sine defibrillation waveform | 1.5ms < Tp < 2.5ms; 3ms < Tw50 < 5.5ms |
| Output polarity | Positive and negative polarity output can be freely set |
| Test 1 Program | First send 3 positive voltage pulse sequences (each pulse interval is 20+2s), then send a negative voltage pulse after an interval of 60+2s |
| Test 2 voltage | 140+70V |
| Phase switching | Single phase/double phase can be set freely |
| Monophasic/Biphasic Truncated Exponential Defibrillation Waveform | 9. 5ms<Td<10.5ms 1μs<tr<5μs 1μs<tf<5μs |
| Test 2 Program | First send 3 positive polarity single-phase voltage pulse sequences (each pulse interval is 20+2s), then send a negative polarity voltage pulse after an interval of 60+2s |
| Evaluation Criteria | Active implantable medical devices are tested for compliance by checking that they have not been permanently affected and can be reprogrammed to restore settings after completing the steps of Test 1 and Test 2. |
| Number of trials | 1 – 999 times |
| Pulse generator output mode | Floating output |
| Input Power | AC 220V±10%, 50Hz/60Hz |
| Dimensions | 680*460*200mm |
| weight | About 30 kg |
Test Waveform
FAQ
Related Products
Related News
In the complex world of electrical engineering and manufacturing, ensuring the safety of electrical components is paramount. One of the […]
For plastic insulation frames, given the high heat generated by the copper wires and iron core, if the flame retardant […]
The glow wire test (GWT) is a cornerstone fire hazard assessment method in electrical and electronic product safety, as defined […]