Front view of the UL 923 microwave oven door test equipment with a stainless-steel body and spring-force mechanism.
Left-angle view of the UL 923 microwave oven door test equipment in an appliance safety laboratory.
Right-angle laboratory view of the UL 923 microwave oven door spring-force test device.
Front view of the UL 923 microwave oven door test equipment with a stainless-steel body and spring-force mechanism.
Left-angle view of the UL 923 microwave oven door test equipment in an appliance safety laboratory.
Right-angle laboratory view of the UL 923 microwave oven door spring-force test device.

UL 923 Microwave Oven Door Test Equipment

The UL 923 Microwave Oven Door Test Equipment is a stainless-steel spring-force application device developed for the microwave oven door opening and closing procedures referenced in UL 923 Clause 40.2. Available with 66 N, 89 N, 133 N and 222 N force options, it supports laboratories in applying selected mechanical forces during household and commercial microwave oven door evaluation.

  • Standards-Based Door Testing
    The Microwave Oven Door Test Equipment supports the door operation procedures referenced in UL 923 Clause 40.2. Clause numbering should be confirmed according to the standard edition used by the laboratory.
  • Applicable Microwave Ovens
    Suitable for household and commercial microwave cooking appliances, including applicable hinged and sliding door designs.
  • Selectable Test Forces
    Available with four force options for opening, closing and related microwave oven door assembly procedures.
  • Extended Laboratory Configuration
    Microwave survey meters, door endurance testers, impact devices and additional test accessories are supplied separately.

UL 923 Microwave Oven Door Test Equipment Product Overview

A microwave oven door forms part of the appliance’s microwave containment and safety interlock system. Mechanical stress may affect the position of the door, hinges, latches, viewing screen, sealing surfaces or interlock components.

The UL 923 Microwave Oven Door Test Equipment enables laboratories to reproduce the spring-applied door movement required by the referenced test procedure. After testing, engineers can inspect whether the door remains intact, correctly aligned and suitable for subsequent safety evaluation.

The Microwave Oven Door Test Equipment performs the force-application portion of the procedure. Microwave radiation emission measurement requires a separate microwave survey meter when specified by the complete test program.

Technical Specifications

Parameter Specification
Product Name UL 923 Microwave Oven Door Test Equipment
Applicable Standard UL 923
Primary Referenced Clause Clause 40.2
Available Force Options 66 N / 89 N / 133 N / 222 N
Spring Constant 1.05 N/mm
Material Stainless steel
Test Object Microwave oven door assemblies
Appliance Types Household and commercial microwave cooking appliances
Applicable Door Designs Hinged or sliding doors, depending on the selected procedure
Product Certificate CE certificate
Microwave Survey Meter Supplied separately
Additional Test Fixtures Available separately upon request

Force accuracy, tolerance and calibration documentation are not specified in the current product information. These requirements for the UL 923 Microwave Oven Door Test Equipment should be confirmed separately when relevant.

Test Purpose and Safety Relevance

Microwave oven doors are repeatedly opened, closed and subjected to mechanical forces during normal use. Door assembly testing helps evaluate whether these forces may affect:

  • Door alignment
  • Hinges and hinge supports
  • Latches and locking components
  • Safety interlock operation
  • Viewing screen barriers
  • Door seals and sealing surfaces
  • Door position relative to the enclosure

The Microwave Oven Door Test Equipment performs the force-application portion of the procedure. It does not independently measure microwave radiation emission or determine the overall compliance of the appliance.

UL 923 Microwave Oven Door Test Equipment Test Method

UL 923 Microwave Oven Door Opening and Closing Test

The door starts from a position approximately midway between fully open and fully closed. The selected device applies force in the intended direction while an opposite restraining force controls the initial movement.

Door Opening Test

For the UL 923 Microwave Oven Door Test Equipment opening procedure, the force is applied from the midpoint position toward the fully open position.

For a hinged door, the force is applied to the inside surface near the free edge. For a sliding door, it is applied to the handle in the intended direction of travel.

Referenced minimum opening force: 66 N

Door Closing Test

The closing procedure starts with the door approximately midway between fully open and fully closed.

For a hinged door, the force is applied to the outside surface near the free edge. For a sliding door, it is applied to the handle in the closing direction.

Referenced minimum closing force: 89 N

Spring-Applied Impulse Principle

The UL 923 Microwave Oven Door Opening and Closing Test uses a spring device with a listed spring constant of 1.05 N/mm.

Releasing the opposite restraining force allows the stored spring energy to move the door to its fully open or fully closed position.

Standard Edition and Clause Mapping

The original UL 923 Microwave Oven Door Test Equipment documentation references UL 923 Clause 40.2. In other editions of UL 923, the corresponding all-door operation requirements may appear under Clause 45.2.

UL 923 Clause 45.2 Spring Scale

The term UL 923 Clause 45.2 Spring Scale refers to the spring scale or equivalent force device used to produce the specified microwave oven door movement.

Customers working with a UL 923 Clause 45.2 Spring Scale requirement should provide the applicable standard edition so the clause mapping and force configuration can be checked.

Force Options and Selection

The UL 923 Microwave Oven Door Test Equipment can be supplied with a selected nominal force of 66 N, 89 N, 133 N or 222 N.

Force Typical Application
66 N Minimum force associated with the Clause 40.2 door opening procedure
89 N Minimum force associated with the Clause 40.2 door closing procedure
133 N Optional force for related commercial microwave door assembly requirements
222 N Optional force for related side-hinged or bottom-hinged door procedures

Force selection should consider the applicable UL 923 edition, test clause, appliance classification, door construction and installation arrangement. This product does not include 445 N or 667 N force configurations.

Product Features

The UL 923 Microwave Oven Door Test Equipment is designed around a defined force-application function for microwave oven door assembly evaluation.

Four Force Configurations

Available in 66 N, 89 N, 133 N and 222 N versions.

Specified Spring Response

Listed spring constant of 1.05 N/mm.

Stainless-Steel Construction

Suitable for regular handling in appliance laboratories.

Dedicated Force Application

Designed for a standards-related door movement procedure.

Compliance Scope

The UL 923 Microwave Oven Door Test Equipment supports the door operation procedure referenced in UL 923 Clause 40.2. It does not represent a complete UL 923 test system or provide UL certification for the microwave oven being tested.

Not included in the standard product:

  • Microwave survey meter
  • Automated door endurance tester
  • Door impact test device
  • Sample mounting fixture
  • Anti-tilting arrangement
  • Wooden dowel
  • 445 N or 667 N force device

A CE product certificate is available. The CE certificate should not be interpreted as UL approval or UL certification.

Technician using UL 923 microwave oven door test equipment to apply force near the free edge of an open door.

Typical Applications

The Microwave Oven Door Test Equipment supports standards-related testing, engineering evaluation and internal quality activities for microwave oven door assemblies.

  • Microwave oven product development
  • Door hinge and latch verification
  • UL 923 pre-compliance evaluation
  • Household appliance safety testing
  • Commercial microwave oven testing
  • Factory quality assurance
  • Third-party testing laboratories
  • Certification preparation laboratories

Laboratory Test Workflow

A typical UL 923 Microwave Oven Door Test Equipment workflow includes sample identification, force selection, controlled spring-force application and post-test inspection.

  1. Confirm the applicable UL 923 edition and test clause.
  2. Identify the appliance type and door construction.
  3. Select the required 66 N, 89 N, 133 N or 222 N configuration.
  4. Install or stabilize the microwave oven in the required arrangement.
  5. Position the door and apply the actuating and restraining forces.
  6. Remove the restraint to produce the spring-applied movement.
  7. Inspect the door, hinges, latches, interlocks and sealing surfaces.
  8. Measure microwave radiation emission separately when required.

Laboratory and Procurement Value

The UL 923 Microwave Oven Door Test Equipment provides a dedicated device for a clearly defined door assembly procedure without requiring a complete automated endurance system.

Manufacturers

Supports design comparison and pre-compliance evaluation.

Testing Laboratories

Provides a clause-oriented force application device.

Procurement Teams

Allows force devices and supporting instruments to be selected separately.

Configuration Notes

The standard supply of the UL 923 Microwave Oven Door Test Equipment covers the selected spring-force device. A microwave survey meter and other laboratory accessories are supplied separately.

Additional equipment available upon request:

  • Microwave radiation survey meters
  • Microwave oven door endurance testers
  • Microwave door impact devices
  • Sample mounting and stabilizing fixtures
  • Bottom-hinged door test accessories
  • Customized force application devices

The final UL 923 Microwave Oven Door Test Equipment configuration should be selected according to the standard edition, required force, door type and complete laboratory test scope.

Compliance & Regulatory Assurance

TheUL 923UL 923equired for the referenced door operation test. Optional 133 N and 222 N configurations are available for related microwave oven door assembly requirements.

As with any standard-related test equipment, final compliance depends on the complete laboratory arrangement, including the applicable UL 923 edition, selected clause, appliance installation method, door construction, force application position, restraining-force alignment, post-test inspection and microwave radiation measurement where required. A separate microwave survey meter and additional door test fixtures can be supplied according to the project scope. The available CE product certificate should not be interpreted as UL approval or certification of the tested microwave oven.

Technical Datasheet
UL 923 Microwave Oven Door Test Equipment
Product overview, Clause 40.2 test application, force configurations, technical specifications and laboratory setup guidance.

Download PDF

Technical Inquiry & Expert Support

To confirm whether the UL 923 Microwave Oven Door Test Equipment matches your test requirement, please provide the key information below when sending an inquiry. This helps confirm the applicable standard edition, door type, required force and supporting laboratory equipment before quotation.

Information Needed Description
Applicable Standard Confirm the applicable UL 923 edition and door assembly clause. The current product information references Clause 40.2; other editions may use Clause 45.2.
Appliance and Door Type Household or commercial microwave oven, together with the installation arrangement and hinged, sliding, side-hinged or bottom-hinged door construction.
Required Force Select the required 66 N, 89 N, 133 N or 222 N force configuration and confirm the required quantity.
Test Setup Provide the sample mounting method, force application position, restraining-force arrangement and any existing laboratory fixtures.
Supporting Equipment Confirm whether a microwave survey meter, door endurance tester, impact device, mounting fixture or other related equipment is required.
Documentation Needs Confirm whether a product datasheet, CE product certificate, inspection record or other project documentation is required.

Note: Final suitability should be reviewed together with the complete microwave oven test arrangement, applicable UL 923 edition, selected force configuration and required supporting instruments.

UL923 Microwave Cooking Appliances -Door Assembly Tests

UL 923 Microwave Oven Door Test Equipment Detail Display

UL 923 Microwave Oven Door Test Equipment FAQ

What is the UL 923 Microwave Oven Door Test Equipment used for?
The equipment applies a specified spring force during microwave oven door opening, closing and related door assembly tests. It helps laboratories evaluate whether mechanical operation affects the door, hinges, latches, interlocks, viewing screen or sealing surfaces. Post-test inspection and separate microwave radiation measurement may also be required.
Which UL 923 clause applies to this equipment?
The original product information references UL 923 Clause 40.2 for microwave oven door operation testing. In other editions, corresponding all-door requirements may appear under Clause 45.2. Customers should provide the applicable UL 923 edition so the clause mapping, force configuration and supporting equipment can be confirmed correctly.
Which force options are available?
The UL 923 Microwave Oven Door Test Equipment is available in 66 N, 89 N, 133 N and 222 N configurations. The 66 N and 89 N options relate to the referenced opening and closing procedures. The 133 N and 222 N options may support related door assembly tests, depending on the applicable clause and door construction.
What is the function of the 1.05 N/mm spring constant?
The 1.05 N/mm spring constant produces the spring response used in the referenced microwave oven door opening and closing procedure. A restraining force initially controls the door movement. When the restraint is removed, the stored spring energy allows the door to complete the specified opening or closing action.
Can the equipment test both household and commercial microwave ovens?
The referenced UL 923 door operation procedures cover household and commercial microwave cooking appliances. The required force, number of operations and test arrangement may differ according to appliance classification, door type and installation method. Customers should confirm whether the sample is household or commercial when selecting the equipment.
Is the equipment suitable for hinged and sliding microwave oven doors?
It can support hinged or sliding doors when the selected UL 923 procedure applies. For hinged doors, force is generally applied near the free edge. For sliding doors, it is applied to the handle in the intended direction of travel. Side-hinged and bottom-hinged designs may require different force devices or fixtures.
Is a microwave survey meter included with the door test equipment?
No. The product performs the mechanical force-application portion of the door assembly test. A separate microwave survey meter is required when the test program includes post-test microwave radiation emission measurement. KINGPO can provide a suitable survey meter separately according to the laboratory’s measurement requirements.
Does the standard product include mounting fixtures and anti-tilting supports?
Sample mounting fixtures, anti-tilting arrangements, wooden dowels and other door test accessories are not included in the standard force-device supply. Their necessity depends on the microwave oven installation arrangement and applicable test clause. Related fixtures and customized supporting equipment can be discussed separately for the complete laboratory setup.
What is the difference between this device and a microwave oven door endurance tester?
The UL 923 Microwave Oven Door Test Equipment applies a selected spring force during a specified door operation procedure. A door endurance tester automatically performs repeated opening and closing cycles to evaluate long-term wear of hinges, latches and seals. They perform different functions and may both be required in a complete laboratory.
Does using this equipment mean the microwave oven is UL certified?
No. The equipment is designed to support UL 923-related testing, but it does not provide UL certification or independently determine appliance compliance. Final evaluation depends on the correct standard edition, complete test arrangement, sample installation, inspection procedure and required measuring instruments. A CE product certificate is available for the equipment itself.

Related Products

Related News

IEC Standards and Definitions ensure global safety, reliability, and compatibility for electrical and electronic products across industries.
IEC 60335 Safety Standards set strict rules for household appliances, protecting users from electric shock, fire, and mechanical hazards at home.
A Needle Flame Tester evaluates material fire resistance by applying a small, controlled flame to test ignition and self-extinguishing properties.
Global power supply specifications for households and industry: voltage, frequency, plug types, and standards for safe device use worldwide.
Glow Wire Tester checks if electronics resist fire, ensuring your devices meet safety standards and protect your home from electrical fire hazards.

KingPo completed the supply of an IEC 60529 IPX3/IPX4 Tester for SGS Fimko Ltd in Finland in July 2023. The […]

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.