ISO 80369, ISO 5356 and ISO 18250-3 medical connector test equipment calibration service
Medical connector metrology support

Connector Test Equipment Calibration for ISO 80369, ISO 5356 and ISO 18250-3

KingPo provides inspection, maintenance review and third-party accredited laboratory submission support for medical connector gauges, reference connectors and test fixtures used in small-bore connector compliance testing.

In-house dimensional inspectionCMM, thread scanning, roughness, height and vision measurement capability.
Third-party certificate submissionSubmission support to qualified metrology laboratories where applicable.
Medical connector standardsISO 80369, ISO 5356 and ISO 18250-3 related gauges, references and fixtures.
Technical overview

Medical Connector Test Tool Inspection and Calibration Support

Connector test equipment calibration is not limited to checking a single dimension. For medical connector test tools, the practical review may involve connector geometry, taper, thread profile, surface roughness, mating interface, force alignment, torque fixture condition and pressure-related measuring instruments.

KingPo can perform in-house dimensional inspection and condition review before delivery, repair, maintenance or third-party laboratory submission. When customers require an accredited certificate, KingPo can help coordinate submission to a qualified third-party metrology laboratory according to the required item and approved scope.

Standards covered

Calibration Support for ISO 80369, ISO 5356 and ISO 18250-3 Test Equipment

Different medical connector standards require different reference interfaces, gauges and functional fixtures. The final inspection method and certificate scope should be confirmed according to the purchased standard, the customer’s quality procedure and the selected laboratory’s approved calibration scope.

ISO 80369 Series

Small-Bore Medical Connectors

Reference connectors, Luer gauges, leakage fixtures, force fixtures and torque-related tools used for medical small-bore connector verification.

ISO 5356

Anaesthetic and Respiratory Conical Connectors

Conical connector gauges and related measuring tools for anaesthetic and respiratory equipment connector applications.

ISO 18250-3

Enteral Reservoir Connector Tools

Enteral connector test tools, mating features and functional fixtures used for reservoir connector assessment and inspection support.

Important: KingPo does not claim that every inspection or calibration activity is performed under KingPo-owned CNAS or ILAC accreditation. Accredited certificate availability depends on the selected third-party laboratory, the requested measurement item and its approved scope.
In-house capability

Dimensional Inspection and Condition Review Equipment

Before connector test equipment is delivered, repaired or submitted for third-party calibration, KingPo can review critical dimensions and measurement condition using in-house metrology equipment. For complete ISO 80369 product configuration, please review our ISO 80369 Testing Equipment page.

CMM inspection for ISO 80369 medical connector gauges and reference connectors
Coordinate Measuring Machine Critical 3D dimensions, geometry and position tolerance review for ISO 80369, ISO 5356 and ISO 18250-3 gauges, reference connectors and precision fixtures.
Thread scanning inspection for ISO 80369 Luer lock reference connectors
Thread Scanning System Thread profile, pitch, flank angle and connector mating feature inspection for lock interfaces.
Surface roughness testing for ISO 80369 Luer gauges and reference connectors
Surface Roughness Tester Surface finish review on critical mating and sealing surfaces of connector test tools.
Height gauge measurement for medical connector calibration tools
Height Gauge Vertical dimensions, step heights and reference surface checks for connector fixtures and precision gauges.
Vision measurement for ISO 18250-3 enteral connector test tools
Vision Measuring System Non-contact inspection of small profiles, edges, diameters, angles and connector features.
Calibration scope

Connector Test Equipment Calibration Items

KingPo supports connector test equipment calibration review for gauges, reference connectors, fixtures and measuring instruments used in medical connector verification. Feasibility is confirmed before submission because not every item can be certified by the same laboratory or under the same accreditation scope.

Reference Connectors and Gauges

  • ISO 80369-7 Luer gauges and reference connectors
  • ISO 5356 conical connector gauges
  • ISO 18250-3 enteral connector test tools
  • Application-specific mating references

Functional Test Fixtures

  • Leakage and pressure test fixtures
  • Axial separation force fixtures
  • Unscrewing and overriding torque fixtures
  • Stress cracking and alignment fixtures

Related Instruments

  • Force gauges and load cells
  • Torque meters and torque sensors
  • Pressure gauges and transducers
  • Timers, temperature and humidity instruments
ISO 80369, ISO 5356 and ISO 18250-3 medical connector gauge set for calibration service
Product configuration

Need New ISO 80369 Gauges or Reference Connectors?

If your current tools are worn, damaged or not suitable for the required test method, calibration alone may not solve the problem. KingPo can also provide new ISO 80369 Luer gauges, reference connectors and related functional test systems.

Service workflow

Calibration and Submission Workflow

Each project starts with a technical review. This avoids sending the wrong tool to the wrong laboratory and helps customers choose between in-house inspection, repair, replacement or third-party accredited calibration submission.

Submit DetailsSend standard, equipment list, drawing and certificate requirement.
Technical ReviewKingPo checks tool type, condition and applicable method.
In-House CheckDimensional and condition review is performed where needed.
Repair AdviceRepair or replacement is confirmed before certificate submission.
Lab SubmissionTools are submitted to a qualified third-party laboratory if required.
Certificate ReturnCertificate, report or inspection record is returned for review.
Next IntervalKingPo helps explain results and future review recommendations.
Third-party laboratory support

Accredited Certificate Submission Support

For customers requiring third-party accredited certificates, KingPo can assist with submission to qualified metrology laboratories. The final certificate issuer, accreditation mark, measurement item and uncertainty statement are determined by the selected laboratory and its approved scope.

Connector Test Equipment Calibration

Third-Party Accreditation Marks

Example cover page of a third-party test report issued by the Guangdong Institute of Metrology. Depending on the requested project and the laboratory’s approved scope, the final document may be issued as a test report or calibration certificate.

Third-party accredited calibration certificate sample for medical connector test equipment

Third-Party Calibration Certificate Sample

Certificate format reference for medical connector test equipment submitted through qualified third-party laboratories.

Accreditation statement: Accreditation marks shown on third-party certificates belong to the certificate-issuing laboratories and are used only to explain accredited laboratory submission support. KingPo does not claim that all calibration activities are performed under KingPo-owned CNAS or ILAC accreditation unless specifically stated on the issued certificate.
Quotation preparation

Information Required for Calibration Quotation

Providing complete information helps avoid incorrect certificate scope, wrong measurement items or delays caused by missing drawings and serial-number details.

Use this table to prepare connector test equipment calibration quotation information before submitting gauges, reference connectors or fixtures for inspection or third-party laboratory review.
InformationExampleWhy It Matters
Equipment typeISO 80369-7 Luer gauge set, ISO 5356 conical connector gauge, ISO 18250-3 enteral connector fixtureDetermines whether the item can be inspected in-house or submitted for accredited calibration.
Standard and editionISO 80369-7:2021, ISO 5356-1:2015, ISO 18250-3:2018Different editions may require different figures, methods or acceptance criteria.
Figure / Annex / clauseFigure C.1–C.6, connector type, leakage method, torque methodPrevents mismatching the tool with the wrong reference interface or test method.
Certificate requirementIn-house inspection record or third-party accredited calibration certificateDefines laboratory selection, cost, lead time and report format.
Condition and historyNew, used, damaged, after repair, out of calibrationHelps identify whether cleaning, repair or replacement should be considered first.
Quantity and serial numbersOne set, individual gauge, full kit, serial-number listRequired for quotation, tracking and certificate preparation.
Technical references

Reference Standards and Accreditation Resources

Final calibration method, acceptance criteria and certificate requirements should always be confirmed according to the purchased standard, customer specification and the selected third-party laboratory’s approved scope.

Frequently asked questions

Connector Test Equipment Calibration FAQ

Can KingPo provide CNAS or ILAC-recognized calibration certificates?

KingPo can coordinate submission to qualified third-party metrology laboratories when an accredited certificate is required. The final certificate issuer, accreditation mark and calibration scope depend on the selected laboratory’s approved scope.

Is in-house inspection the same as accredited calibration?

No. In-house inspection helps verify dimensional condition, tool condition and manufacturing quality. Accredited calibration is performed and certified by an accredited laboratory within its approved scope.

Which ISO 80369 equipment can be reviewed?

Typical items include ISO 80369-7 Luer gauges and reference connectors, ISO 80369-3 enteral connector references, ISO 80369-6 neural application references, leakage fixtures, force fixtures and torque fixtures. Feasibility should be confirmed according to the exact figure, drawing and certificate requirement.

Can used gauges be repaired before calibration?

KingPo can inspect wear, surface condition and dimensional deviation. If repair or replacement is more appropriate than calibration, KingPo will advise before third-party laboratory submission.

How often should medical connector gauges be calibrated?

The interval depends on the user’s quality system, usage frequency, wear risk, regulatory requirements and customer audit expectations. Many laboratories define an annual or project-based review cycle, but the final interval should follow the user’s internal procedure.

Need calibration support for ISO 80369 gauges or reference connectors?

For ISO 80369, ISO 5356 and ISO 18250-3 connector test equipment, KingPo can support gauge inspection, reference connector review, calibration submission coordination and replacement tool selection when needed. If the tool is worn, damaged or unsuitable for the required method, review the ISO 80369 Testing Equipment page before requesting a certificate.

Application review

Request Connector Test Equipment Calibration Support

Send your ISO 80369, ISO 5356 or ISO 18250-3 equipment list, drawing, serial number and certificate requirement. KingPo will review the inspection route, third-party submission feasibility and recommended next step.

Scroll to Top

Get A Free Quote Now !

Contact Form
If you have any questions, please do not hesitate to contact us.